Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "chromatography" wg kryterium: Wszystkie pola


Tytuł:
Column chromatography as a useful step in purification of diatom pigments
Autorzy:
Tokarek, Wiktor
Listwan, Stanisław
Pagacz, Joanna
Leśniak, Piotr
Latowski, Dariusz
Tematy:
column chromatography
Phaeodactylum tricornutum
fucoxanthin
diadinoxanthin
diatoxanthin
thin layer chromatography
Pokaż więcej
Wydawca:
Polskie Towarzystwo Biochemiczne
Powiązania:
https://bibliotekanauki.pl/articles/1038760.pdf  Link otwiera się w nowym oknie
Opis:
Fucoxanthin, diadinoxanthin and diatoxanthin are carotenoids found in brown algae and most other heterokonts. These pigments are involved in photosynthetic and photoprotective reactions, and they have many potential health benefits. They can be extracted from diatom Phaeodactylum tricornutum by sonication, extraction with chloroform : methanol and preparative thin layer chromatography. We assessed the utility of an additional column chromatography step in purification of these pigments. This novel addition to the isolation protocol increased the purity of fucoxanthin and allowed for concentration of diadinoxanthin and diatoxanthin before HPLC separation. The enhanced protocol is useful for obtaining high purity pigments for biochemical studies.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dozowanie próbek gazów do kolumny chromatograficznej o podwyższonym ciśnieniu
Injection of gas samples to the high-pressure chromatography column
Autorzy:
Czech, K.
Słomkiewicz, P. M.
Tematy:
kolumny chromatograficzne
chromatografia gazowa
gas chromatography
chromatography column
Pokaż więcej
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Powiązania:
https://bibliotekanauki.pl/articles/270412.pdf  Link otwiera się w nowym oknie
Opis:
Opracowano metodę dozowania próbek gazowych do kolumn chromatograficznych o podwyższonym ciśnieniu za pomocą strzykawki i zbudowano urządzenie służące do tego celu. Wykonano badania określające przydatność skonstruowanego urządzenia w porównaniu do tradycyjnej strzykawki do próbek gazowych.
The method of gas sampling by syringe to high pressure chromatography column was elaborated and the apparatus used to this aim was built. The usefulness investigations for comparison constructed device to traditional syringe to gas samples were made.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Retention mechanism of sulfonamides in micellar reversed phase liquid chromatography
Autorzy:
Szymański, A.
Tematy:
micellar liquid chromatography
quantitative structure-activity relationships
sulfonamides
Pokaż więcej
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydział Technologii i Inżynierii Chemicznej
Powiązania:
https://bibliotekanauki.pl/articles/347037.pdf  Link otwiera się w nowym oknie
Opis:
A mechanism of retention of sulfonamides in the micellar liquid chromatography, based on similar models verified for other compounds, was proposed. The magnitudes of hydrophobic and electrostatic interactions of sulfonamides were estimated for different concentrations of surfactant in the mobile phase and at varied pH. With increasing SDS concentrations and at a constant pH, a decrease in the hydrophobic interaction intensity was noted. When pH is varied, the values of the constant, describing the hydrophobicity of the sulfonamides, remained at an approximately same level (taking into account the standard deviation values). Greater differences were observed in the constants related to the electrostatic interactions informing about the increase or decrease in retention, following from ionic interactions. For each sulfonamide, the molar fraction of the ionic fractions present in the mobile phase was calculated from the formula derived, which permitted determination of the type of electrostatic interactions, varying with the eluent’s changing pH. On the basis of the chromatographic data collected, it was established that retention of sulfonamides in the SDS micellar system depends on the hydrophobic and electrostatic interactions. For varied pH values, the hydrophobic interactions of sulfonamides did not change significantly, all changes in the retention of the sulfonamides were attributed to changes in the electrostatic interactions.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two-dimensional gas chromatography – principles and application in fruits analysis
Autorzy:
Lubinska, Martyna
Namieśnik, Jacek
Tematy:
aparature
applications
history
principles
two-dimensional gas chromatography
Pokaż więcej
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Powiązania:
https://bibliotekanauki.pl/articles/1179569.pdf  Link otwiera się w nowym oknie
Opis:
Two-dimensional gas chromatography is a rapidly developing analytical technique. One of the major uses of this technique is its use for food analysis. The paper presents the principle of operation and history of this analytical technique. The specification of the two-dimensional gas chromatography technique has been discussed. The principles of separation of ingredients and application of the method, particularly in the analysis of food products, have also been described. A literature review was also done, presenting the use of two-dimensional gas chromatography for the analysis of fruit and fruit products.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
One-step purification of vitronectin from human plasma by affinity chromatography on phage-displayed peptides
Autorzy:
Skurzynski, Szymon
Tematy:
affinity chromatography
phage display
vitronectin
Pokaż więcej
Wydawca:
Polskie Towarzystwo Biochemiczne
Powiązania:
https://bibliotekanauki.pl/articles/1040429.pdf  Link otwiera się w nowym oknie
Opis:
A novel affinity purification method for rapid isolation of vitronectin (VN) from human plasma is described. Recently we have used phage display technology to obtain clones expressing peptides with high binding activity for VN. The isolated "strong VN binders" were covalently coupled to CNBr-activated Sepharose. Human plasma was applied to the column and bound VN was eluted using 0.5 M acetic acid, giving purity exceeding 90%. The developed method is a convenient alternative to conventional antibody-antigen affinity chromatography techniques for purification of VN, as it offers low ligand cost, is rapid and ensures good protein recovery from human plasma.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowania chromatografii jonowej w przemyśle
Industrial applications of ion chromatography
Autorzy:
Michalski, R.
Tematy:
chromatografia jonowa
aniony
kationy
środowisko
przemysł
ion chromatography
anions
cations
environment
industry
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Powiązania:
https://bibliotekanauki.pl/articles/142380.pdf  Link otwiera się w nowym oknie
Opis:
Do najważniejszych zastosowań chromatografii jonowej, która stanowi odmianę wysokosprawnej chromatografii cieczowej, należy oznaczanie nieorganicznych anionów takich jak: F-, Cl-, NO2-,NO3-, Br-, PO43-, SO42- oraz kationów, takich jak: Na+, K+, NH4+, Ca2+ i Mg2+ w różnego rodzaju wodach i ściekach. Wprowadzanie nowych wysokowydajnych i selektywnych wymieniaczy jonowych do kolumn jonowymiennych, a także nowych metod przygotowania próbek i czułych sposobów detekcji, pozwolił rozszerzyć zakres tych zastosowań do praktycznie wszystkich substancji tworzących formy jonowe, a także takich, które mogą być pośrednio wykrywane tą metodą, po odpowiednich reakcjach derywatyzacji. W pracy przestawiono wybrane zastosowania chromatografii jonowej w badaniach próbek pochodzących z różnych gałęzi przemysłowych, takich jak przemysł spożywczy, farmaceutyczny, energetyczny, chemiczny, metalurgiczny czy papierniczy.
The most important applications of ion chromatography, which is a variation of high performance liquid chromatography, is determination of inorganic anions (e.g. F-, Cl-, NO2-,NO3-, Br-, PO43-, SO42-) and cations (e.g. Na+, K+, NH4+, Ca2+ i Mg2+) in various types of water and wastewater. The introduction of new highly efficient and selective stationary phases for ion-exchange columns, as well as new methods of sample preparation and sensitive detection methods, allow to broaden the scope of these applications for all ion-forming substances, as well as those that can be indirectly detected by this method after appropriate derivatization reactions. The paper describes selected applications of ion chromatography in different industry branches, such as food, pharmaceutical, energy, chemical, metallurgical and paper industry.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Alphacypermethrin in the Air by Capillary Gas Chromatography
Autorzy:
Pomorska, K.
Tematy:
alphacypermethrin determination
Fastac
capillary gas chromatography
chromatografia gazowa kapilarna
powietrze
środowisko pracy
Pokaż więcej
Wydawca:
Centralny Instytut Ochrony Pracy
Powiązania:
https://bibliotekanauki.pl/articles/91149.pdf  Link otwiera się w nowym oknie
Opis:
A new method for sampling and chemical analysis of alphacypermethrin in workplace air has been described. Air samples were taken using a glass tube filled with silica gel with chemically bounded octadecyl phase. Chromatographic determinations were conducted using an HP-5 capillary column (10 m x 0.53 mm) and an electron-capture detector. Alphacypermethrin recovery was 100.15%. The calculated detection limit for a 60-L air sample was 0.0001 mg/m3.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies