Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kozik, T." wg kryterium: Autor


Tytuł:
Modeling of the crystalline structure of the complex system containing doped polyaniline by use of genetic algorithms
Autorzy:
Kozik, T.
Luzny, W.
Tematy:
polyaniline
genetic algorithms
computer modeling of crystalline structure
Pokaż więcej
Wydawca:
Tomasz Mariusz Majka
Powiązania:
https://bibliotekanauki.pl/articles/134891.pdf  Link otwiera się w nowym oknie
Opis:
The structure of polyaniline (PANI) protonated with camphorsulphonic acid (CSA) has been subject to research for a long time. Despite several, various models being proposed throughout the years, there is still no model widely accepted as the only correct and final one of its crystalline phase. In this paper a computer program named MoleculeEditor is described. Created basing on the concepts of an existing but significantly different program named CrystalFinder, it is a software dedicated to finding a model of the crystalline regions of the PANI/CSA system based on an input X-ray diffraction pattern. In its search it takes advantage of the genetic algorithm technique for optimizing the model parameters to fit the computed diffraction pattern to the one loaded as input. A successful example of it being employed to find the parameters of a prepared beforehand, fictional structure of the system, is presented. Conclusions drawn from this application of the prepared software cannot be ignored in the further search for the actual model of this complex system using this program. Obtaining results from MoleculeEditor for actual, experimental data is however still in progress.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of solvents on structural anisotropy of polyaniline thin films
Wpływ rozpuszczalnika na anizotropię cienkich warstw polianiliny
Autorzy:
Śniechowski, M.
Kozik, T.
Łużny, W.
Tematy:
polyaniline
surface diffraction
simulations
film anisotropy
solvent
polianilina
dyfrakcja powierzchniowa
symulacje
anizotropia cienkich warstw
rozpuszczalnik
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Powiązania:
https://bibliotekanauki.pl/articles/946935.pdf  Link otwiera się w nowym oknie
Opis:
X-ray surface diffraction experiments performed on polyaniline/camphorsulfonic acid (PANI/CSA) thin films reveal high anisotropy of the five main crystalline peaks. This anisotropy is different for samples cast from m-cresol and cast from trifluoroacetic acid (TFA). Taking advantage of a recently published crystalline unit cell model, intensity distribution maps are calculated for these two types of samples. The anisotropy is in agreement with experiment, further validating the PANI/CSA model and showing that solvent molecules are not present in the unit cell.
Cienkowarstwowe, wykazujące silną anizotropię próbki polianilina/kwas kamforosulfonowy (PANI/CSA) zbadano metodą dyfrakcji powierzchniowej promieniowania rentgenowskiego. Wyniki pomiarów w geometriach: transmisyjnej, odbiciowej i pośrednich wykazały różnice między natężeniami pięciu głównych maksimów krystalicznych. Anizotropia próbek była różna w wypadku użycia różnych rozpuszczalników (m-cresol, kwas trifluorooctowy). Niedawno opublikowany model struktury PANI/CSA wykorzystano do obliczenia map natężeń, a następnie do porównań z wynikami pomiarów. Proponowany model poprawnie opisuje uporządkowanie w próbkach folii z PANI/CSA wylanych z różnych rozpuszczalników, bez konieczności uwzględniania w nim cząsteczek rozpuszczalnika. Świadczy to o tym, że cząsteczki rozpuszczalnika nie występują w strukturze PANI/CSA jako składniki komórki elementarnej.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Challenge and adventure: twenty years of searching for the model structure of the polyaniline/camphorsulfonic acid conducting polymer system leading to an artificial intelligence approach
Wyzwanie i przygoda: dwadzieścia lat poszukiwań modelu struktury polimerowego systemu przewodzącego polianilina/kwas kamforosulfonowy prowadzących do wykorzystania metod sztucznej inteligencji
Autorzy:
Kozik, T.
Śniechowski, M.
Łużny, W.
Tematy:
polyaniline
X-ray diffraction
modeling
simulations
polianilina
dyfrakcja rentgenowska
modelowanie
symulacje
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Powiązania:
https://bibliotekanauki.pl/articles/946936.pdf  Link otwiera się w nowym oknie
Opis:
The search for the model structure of polyaniline/camphorsulfonic acid (PANI/CSA) began approximately twenty years ago and remained an unsolved problem. Recently, a new molecular dynamics based model was published in which the system forms a structure of alternating double layers. Having brought together all available information regarding the system, an artificial intelligence approach was formulated, which resulted in finding a model of the crystalline regions of the polymer system in agreement with various experimental results. The approach is thoroughly described due to its versatility.
Poszukiwania modelu struktury systemu polianilina/kwas kamforosulfonowy (PANI/CSA) rozpoczęły się przed ok. dwudziestu laty, nadal jednak problem pozostaje nierozwiązany. W minionych latach opublikowano nowy model otrzymany w wyniku symulacji metodą dynamiki molekularnej. Zgodnie z jego przewidywaniami w systemie PANI/CSA powstaje struktura naprzemiennych dwuwarstw. Na podstawie dostępnej wiedzy sformułowano wykorzystującą algorytmy sztucznej inteligencji metodę, która doprowadziła do znalezienia modelu wykazującego zgodność z różnego rodzaju doświadczeniami. Ze względu na uniwersalność opracowanej metody, szczegółowo ją opisano.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
Autorzy:
Kamińska, D.
Gajos, A.
Czerwiński, E.
Bednarski, T.
Białas, P.
Gorgol, M.
Jasińska, B.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Tematy:
discrete symmetries
J-PET
ortho-positronium
Pokaż więcej
Wydawca:
Instytut Chemii i Techniki Jądrowej
Powiązania:
https://bibliotekanauki.pl/articles/147408.pdf  Link otwiera się w nowym oknie
Opis:
In this paper, we present prospects for using the Jagiellonian positron emission tomograph (J-PET) detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence of physics phenomena beyond the standard model. Previous measurements resulted in violation amplitude parameters for CP and CPT symmetries consistent with zero, with an uncertainty of about 10−3. The J-PET detector allows to determine those values with better precision, thanks to the unique time and angular resolution combined with a high geometrical acceptance. Achieving the aforementioned is possible because of the application of polymer scintillators instead of crystals as detectors of annihilation quanta.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the compress sensing theory for improvement of the TOF resolution in a novel J-PET instrument
Autorzy:
Raczyński, L.
Moskal, P.
Kowalski, P.
Wiślicki, W.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Rudy, Z.
Salabura, P.
Gupta-Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Zieliński, M.
Zoń, N.
Tematy:
compressed sensing
positron emission tomography
time-of-flight
Pokaż więcej
Wydawca:
Instytut Chemii i Techniki Jądrowej
Powiązania:
https://bibliotekanauki.pl/articles/146280.pdf  Link otwiera się w nowym oknie
Opis:
Nowadays, in positron emission tomography (PET) systems, a time of fl ight (TOF) information is used to improve the image reconstruction process. In TOF-PET, fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten signifi cantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to compressive sensing (CS) theory, information about the shape and amplitude of the signals is recovered. In this paper, we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50-ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Autorzy:
Sharma, N. G.
Silarski, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Tematy:
J-PET detector
Mahalanobis distance
time resolution
threshold levels
Pokaż więcej
Wydawca:
Instytut Chemii i Techniki Jądrowej
Powiązania:
https://bibliotekanauki.pl/articles/146937.pdf  Link otwiera się w nowym oknie
Opis:
The J-PET detector being developed at the Jagiellonian University is a positron emission tomograph composed of the long strips of polymer scintillators. At the same time, it is a detector system that will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit time and hit position of the gamma quantum. In order to take advantage of this fact, a dedicated sampling front-end electronics that enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity, we use the Mahalanobis distance. The achievable position and time resolution depend on the number and values of the threshold levels at which the signal is sampled. A reconstruction method as well as preliminary results are presented and discussed.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies of unicellular microorganisms Saccharomyces cerevisiae by means of positron annihilation lifetime spectroscopy
Autorzy:
Kubicz, E.
Jasińska, B.
Zgardzińska, B.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rajfur, Z.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Tematy:
environmental scanning electron microscopy (ESEM)
free volume
inverted microscopy
positron annihilation
positronium
yeasts
Pokaż więcej
Wydawca:
Instytut Chemii i Techniki Jądrowej
Powiązania:
https://bibliotekanauki.pl/articles/147902.pdf  Link otwiera się w nowym oknie
Opis:
Results of positron annihilation lifetime spectroscopy (PALS) and microscopic studies on simple microorganisms, brewing yeasts, are presented. Lifetime of ortho-positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer-lived component) for lyophilized and aqueous yeasts, respectively. Also hygroscopicity of yeasts in time was examined, allowing to check how water – the main component of the cell – affects PALS parameters, thus lifetime of o-Ps were found to change from 1.2 to 1.4 ns (shorter-lived component) for the dried yeasts. The time sufficient to hydrate the cells was found below 10 hours. In the presence of liquid water, an indication of reorganization of yeast in the molecular scale was observed. Microscopic images of the lyophilized, dried, and wet yeasts with best possible resolution were obtained using inverted microscopy (IM) and environmental scanning electron microscopy (ESEM) methods. As a result, visible changes to the surface of the cell me mbrane were observed in ESEM images.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
Autorzy:
Wieczorek, A.
Zgardzińska, B.
Jasińska, B.
Gorgol, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Silarski, A.
Strzelecki, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Tematy:
free volume
positron annihilation
polystyrene
positronium
scintillator
Pokaż więcej
Wydawca:
Instytut Chemii i Techniki Jądrowej
Powiązania:
https://bibliotekanauki.pl/articles/147132.pdf  Link otwiera się w nowym oknie
Opis:
The polystyrene doped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260, 283, and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Framework for the J-PET Scanner
Autorzy:
Krzemień, W.
Gajos, A.
Gruntowski, A.
Stola, K.
Trybek, D.
Bednarski, T.
Białas, P.
Czerwiński, E.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Tematy:
87.57.nf
87.57.uk
29.85.-c
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1402621.pdf  Link otwiera się w nowym oknie
Opis:
J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies