Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Lee, P." wg kryterium: Autor


Tytuł:
Applying LCS to affective image classification in spatial - frequency domain
Autorzy:
Lee, P. -M.
Hsiao, T.-C.
Tematy:
image classification
pattern recognition
Hilbert-Huang transform
HHT
empirical mode decomposition
EMD
Hilbert transform
HT
Extended Classifier Systems
XCSs
Area Under Curve
AUC
Radial-Basis Function Network
RBF Network
LCS
Pokaż więcej
Wydawca:
Społeczna Akademia Nauk w Łodzi. Polskie Towarzystwo Sieci Neuronowych
Powiązania:
https://bibliotekanauki.pl/articles/91808.pdf  Link otwiera się w nowym oknie
Opis:
Recent studies have utilizes color, texture, and composition information of images to achieve affective image classification. However, the features related to spatial-frequency domain that were proven to be useful for traditional pattern recognition have not been tested in this field yet. Furthermore, the experiments conducted by previous studies are not internationally-comparable due to the experimental paradigm adopted. In addition, contributed by recent advances in methodology, that are, Hilbert-Huang Transform (HHT) (i.e. Empirical Mode Decomposition (EMD) and Hilbert Transform (HT)), the resolution of frequency analysis has been improved. Hence, the goal of this research is to achieve the affective image-classification task by adopting a standard experimental paradigm introduces by psychologists in order to produce international-comparable and reproducible results; and also to explore the affective hidden patterns of images in the spatial-frequency domain. To accomplish these goals, multiple human-subject experiments were conducted in laboratory. Extended Classifier Systems (XCSs) was used for model building because the XCS has been applied to a wide range of classification tasks and proved to be competitive in pattern recognition. To exploit the information in the spatial-frequency domain, the traditional EMD has been extended to a two-dimensional version. To summarize, the model built by using the XCS achieves Area Under Curve (AUC) = 0.91 and accuracy rate over 86%. The result of the XCS was compared with other traditional machine-learning algorithms (e.g., Radial-Basis Function Network (RBF Network)) that are normally used for classification tasks. Contributed by proper selection of features for model building, user-independent findings were obtained. For example, it is found that the horizontal visual stimulations contribute more to the emotion elicitation than the vertical visual stimulation. The effect of hue, saturation, and brightness; is also presented.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of various carbohydrate sources on postprandial glucose, insulin and NEFA concentrations in obese cats
Autorzy:
Mori, A.
Ueda, K.
Lee, P.
Oda, H.
Ishioka, K.
Sako, T.
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/31194.pdf  Link otwiera się w nowym oknie
Opis:
Carbohydrate is an important source of energy, which can significantly affect postprandial blood glucose and insulin levels in cats. In healthy animals, this is not a big concern; however, in obese and diabetic animals, this is an important detail. In the present study, the impact of four different carbohydrate sources (glucose, maltose, corn starch, and trehalose) on short-term post-prandial serum glucose, insulin, and non-esterified fatty acid (NEFA) concentrations was investigated with four obese cats. Each of the carbohydrate sources was added to a commercial wet food diet for feeding the animals. A significant difference was observed in postprandial glucose, insulin, and NEFA area under the curve (AUC) values between each carbohydrate source in obese cats. Furthermore, glucose and maltose induced the highest postprandial glucose and insulin AUC values, whereas trehalose induced the lowest postprandial glucose and insulin AUC value amongst all carbohydrate sources, respectively, in obese cats. However, trehalose has a higher risk of inducing side effects, such as diarrhea, as compared to other carbohydrate sources. As such, different carbohydrate sources appear to have a very significant impact on post-prandial glycemia and subsequent insulin requirement levels in obese cats. These results might be useful when selecting a prescription diet for obese or diabetic cats. In addition, maltose appears to be capable of inducing experimentally evoked postprandial hyperglycemia in obese cats, which may serve as a good tool for use to check the impact and effectiveness of newly developed oral hypoglycemic drugs or supplements for cats in future experiments.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
D(3He,p)4He and D(d,p)3H fusion in a small plasma focus operated in a deuterium helium-3 gas mixture
Autorzy:
Springham, S.
Sim, T.
Rawat, T.
Lee, P.
Patran, A.
Shutler, P.
Tan, T.
Lee, S.
Tematy:
plasma focus
deuterium
helium-3
fusion
CR-39
track detectors
Pokaż więcej
Wydawca:
Instytut Chemii i Techniki Jądrowej
Powiązania:
https://bibliotekanauki.pl/articles/147428.pdf  Link otwiera się w nowym oknie
Opis:
Abstract A 3 kJ plasma focus was operated with a 3He-D2 gas mixture, with partial pressures in the ratio of 2:1, corresponding to an atomic number ratio of 1:1 for 3He and D atoms. The fusion reactions D(3He,p)4He and D(d,p)3H were measured simultaneously using CR-39 polymer nuclear track detectors placed inside a pinhole camera positioned on the forward plasma focus axis. A sandwich arrangement of two 1000 mi m thick CR-39 detectors enabled the simultaneous registration of two groups of protons with approximate energies of 16 MeV and 3 MeV arising from the D(3He,p)4He and D(d,p)3H reactions, respectively. Radial track density distributions were obtained from each CR-39 detector and per-shot average distributions were calculated for the two groups of protons. It is found that the D(3He,p)4He and D(d,p)3H proton yields are of similar magnitude. Comparing the experimental distributions with results from a Monte Carlo simulation, it was deduced that the D(3He,p)4He fusion is concentrated close to the plasma focus pinch column, while the D(d,p)3H fusion occurs relatively far from the pinch. The relative absence of D(d,p)3H fusion in the pinch is one significant reason for concluding that the D(3He,p)4He fusion occurring in the plasma focus pinch is not thermonuclear in origin. It is argued that the bulk of the D(3He,p)4He fusion is due to energetic 3He2+ ions incident on a deuterium target. Possible explanations for differing spatial distributions of D(3He,p)4He and D(d,p)3H fusion in the plasma focus are discussed.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
0.2-kJ and 2-kJ high rep rate Dense Plasma foci : their design, technology, and applications
Autorzy:
Dubrovsky, A. V.
Gribkov, V. A.
Ivanov, Y. P.
Lee, P.
Lee, S.
Liu, M.
Samarin, V. A.
Tematy:
dense plasma focus (DPF)
DPF installation
miniature focus chamber
soft and hard X-ray radiation
Pokaż więcej
Wydawca:
Instytut Chemii i Techniki Jądrowej
Powiązania:
https://bibliotekanauki.pl/articles/146546.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents various designs of several medium and small size Dense Plasma Focus (DPF) chambers intended for numerous applications, a description of technologies used in these facilities, and some results reached with these devices by using a number of diagnostic techniques. In present experiments the DP foci have been used mainly as an X-ray source. We discuss here how it is possible to satisfy absolutely new and very strict demands on the construction and technology for the devices to be eventually applied in science and industry. Between these characteristics there are a high repetition rate (typically 1…15 Hz) and a long lifetime (over 1 million shots). Their switching elements, a collector and chambers must withstand a high quasi-continuous heat load (up to 100 kW). High energy density in the central part of the chamber anode and the necessity to provide a channel for radiation extraction demanded a special construction and specific materials implementation in this region. Their X-ray spectrum should be tuned. They have to operate with different working gases and preferably in a wide range of pressures. All these points are discussed in this report. Capabilities of the described techniques are illustrated by results of the recent experimental studies carried out with facilities located at the Nanyang Technological University (NX1) as well as at the Lebedev Physical Institute (PF-0.2).
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Incorporation of Resonators Into Plenum Window
Autorzy:
Lee, H. M.
Haris, A.
Lim, K. M.
Xie, J.
Lee, H. P.
Tematy:
plenum window
Helmholtz resonators
noise pollution
ventilation
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/176744.pdf  Link otwiera się w nowym oknie
Opis:
A plenum window with incorporation of Helmholtz resonators in between two glass panes was tested in a reverberation room. The effects of jagged flap on reducing strength of diffracted sound was also investigated in the present studies where white, traffic and construction noises were examined Turing each set of experiment. When the noise source was located at the central line of the plenum window, the plenum window with Helmholtz resonators was able to mitigate 8.5 dBA, 8.9 dBA and 8.2 dBA of white, traffic and construction noises, respectively, compared with the case of without window. These amounts of noises that attenuated by the plenum window were slightly higher than the case where noise source was diverged 30° away from the plenum window. The effects of jagged flaps on the acoustical performance of the plenum window were negligible. The Helmholtz resonators had the best performance in the frequency region between 900 Hz to 1300 Hz where in this frequency range, the plenum window with Helmholtz resonators was able to attenuate additional 1.7 dBA, 1.9 dBA and 1.6 dBA of white, traffic and construction noises, respectively, compared with the case of without resonators.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies