Tytuł:
Influence of the light source and curing parameters on microhardness of a silorane-based dental composite material
Autorzy:
Malara, P.
Czech, Z.
Świderski, W.
Tematy:
dental composite material
light-curing
silorane
microhardness
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/356555.pdf  Link otwiera się w nowym oknie
Opis:
The aim of the study was to determine the influence of the light source and the light-curing parameters (the distance of the material from the light source and time of light-curing) on microhardness of Flitek Silorane dental composite material. Standardized samples of Filtek Silorane material were cured using two types of Light Curing Units (LCUs) - halogen and LED. The distance of the light source and time of curing differed between samples. The Knoops microhardness was tested using microhardness tester Micromet 5103. Using LED light curing unit allowed to achieve significantly higher microhardness of silorane-based dental material Filtek Silorane than using halogen light curing unit. Decreasing the distance from the light source to the surface of silorane-based material Filtek Silorane improved its microhardness. A prolonged curing time could compensate the drop in microhardness of Filtek Silorane material resulting from an increased distance from the light source to the surface of the material only in a limited range of intervals.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Full Contoured Tooth-Implant Supported 3-Pointic All-Ceramic Denture During Occlusal Load Transfer in Lateral Region
Autorzy:
Żmudzki, J.
Malara, P.
Chladek, G.
Tematy:
biomaterials
denture
zirconium oxide
titanium implant
bone tissue
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/356267.pdf  Link otwiera się w nowym oknie
Opis:
Implant and a tooth supported dentures are avoided by dentists because of uneven distribution of occlusal loads between a stiffer implant and a more pliable tooth. The hypothesis was that a 3-point all-ceramic bridge supported on a natural second premolar tooth and a two-pieces typical implant bears safely mastication loads. The finite element analysis showed that the implant splinted by all-ceramic zirconium bridge with the second premolar was safe under lateral mastication load, but there was found an overload at wide zone of bone tissue around the implant under the load of 800 N. The patients can safely masticate, but comminution of hard food should be avoided and they should be instructed that after such an indiscretion they need to contact a dental professional, because, in spite of integrity of the prosthesis, the bone tissue around the implant may fail and there is a hazard of intrusion of the tooth.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of aging solutions on wear resistance and hardness of selected resin-based dental composites
Autorzy:
Chladek, G.
Basa, K.
Żmudzki, J.
Malara, P.
Nowak, A. J.
Kasperski, J.
Tematy:
właściwości
mikrotwardość
kompozyty stomatologiczne
tarcie
test
properties
microhardness
dental composite
friction
wear test
aging solution
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/306782.pdf  Link otwiera się w nowym oknie
Opis:
Purpose: The purpose of this study was to investigate the effect of different plasticizing aging solutions on wear resistance and hardness of selected universal resin-based dental composites. Methods: Three light cured (one nanofilled, two microhybride) and one hybride chemical cured composites were aged at 37 °C for 48 h in distillated water, ethyl alcohol solution or Listerine mouthwash. After aging the microhardness tests were carried out and then tribological tests were performed in the presence of aging solution at 37 °C. During wear testing coefficients of friction were determined. The maximal vertical loss in micrometers was determined with profilometer. Results: Aging in all liquids resulted in a significant decrease in hardness of the test materials, with the largest values obtained successively in ethanol solution, mouthwash and water. The effect of the liquid was dependent on the particular material, but not the type of material (interpreted as the size of filler used). Introduction of mouthwash instead of water or ethanol solution resulted in a significant reduction in the coefficient of friction. The lowest wear resistance was registered after aging in ethanol and for the chemical cured hybrid composite, but the vertical loss was strongly material dependent. Conclusions: The effect of different aging solution, including commercial mouthrinse, on hardness and wear was material dependent, and cannot be deduced from their category or filler loading. There is no simple correlation between hardness of resin-based dental composites and their wear resistance, but softening of particular composites materials during aging leads to the reduction of its wear resistance.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fabrication Of Scaffolds From Ti6Al4V Powders Using The Computer Aided Laser Method
Wytwarzanie scaffoldów z proszków Ti6Al4V z użyciem komputerowo wspomaganej metody laserowej
Autorzy:
Dobrzański, L. A.
Dobrzańska-Danikiewicz, A. D.
Malara, P.
Gaweł, T. G.
Dobrzański, L. B.
Achtelik-Franczak, A.
Tematy:
biomimetic materials
CAMD
scaffolds
SLM
Ti6Al4V powders
SEM
EDS
materiały biomimetyczne
scaffoldy
selektywne topienie laserowe
proszki Ti6Al4V
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/351661.pdf  Link otwiera się w nowym oknie
Opis:
The aim of the research, the results of which are presented in the paper, is to fabricate, by Selective Laser Melting (SLM), a metallic scaffold with Ti6Al4V powder based on a virtual model corresponding to the actual loss of a patient’s craniofacial bone. A plaster cast was made for a patient with a palate recess, and the cast was then scanned with a 3D scanner to create a virtual 3D model of a palate recess, according to which a 3D model of a solid implant was created using specialist software. The virtual 3D solid implant model was converted into a 3D porous implant model after designing an individual shape of the unit cell conditioning the size and three-dimensional shape of the scaffold pores by multiplication of unit cells. The data concerning a virtual 3D porous implant model was transferred into a selective laser melting (SLM) device and a metallic scaffold was produced from Ti6Al4V powder with this machine, which was subjected to surface treatment by chemical etching. An object with certain initially adopted assumptions, i.e. shape and geometric dimensions, was finally achieved, which perfectly matches the patient bone recesses. The scaffold created was subjected to micro-and spectroscopic examinations.
Celem badań, których wyniki zaprezentowano w artykule jest wytworzenie, metodą selektywnego topienia laserowego (SLM), scaffoldu metalowego z proszku Ti6Al4V na podstawie wirtualnego modelu odpowiadającego rzeczywistemu ubytkowi kości twarzoczaszki pacjenta. Od pacjenta z ubytkiem podniebienia pobierano wycisk gipsowy, który następnie zeskanowano za pomocą skanera 3D, w celu uzyskania wirtualnego modelu 3D ubytku podniebienia, na podstawie którego z użyciem specjalistycznego oprogramowania utworzono model 3D litego implantu. Po zaprojektowaniu indywidualnego kształtu komórki jednostkowej, determinującej wielkość i trójwymiarowy kształt porów scaffoldu, poprzez multiplikację komórek jednostkowych przekształcono wirtualny model 3D implantu litego w model 3D implantu porowatego. Dane dotyczące wirtualnego modelu 3D implantu porowatego przetransferowano do urządzenia służącego do selektywnego topienia laserowego (SLM) i z użyciem tej maszyny z proszku Ti6Al4V wytworzono metalowy scaffold, który poddano obróbce powierzchniowej poprzez trawienie chemiczne. Finalnie otrzymano obiekt o założonych na wstępie: kształcie i wymiarach geometrycznych, które idealnie odpowiadają ubytkowi kości pacjenta. Wytworzony scaffold poddano badaniom mikro i spektroskopowym.
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies