Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Mielke, Stephan" wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
First experimental test of a coded-mask gamma camera for proton therapy monitoring
Autorzy:
Kercz, Monika
Mielke, Linn
Roser, Jorge
Urbanevych, Vitalii
Ostrzołek, Gabriel
Kołodziej, Magdalena
Rafecas, Magdalena
Fenger, Alexander
Rusiecka, Katarzyna
Kołodziej, Barbara
Kasper, Jonas
Wong, Ming-Liang
Wrońska, Aleksandra
Farah, George N.
Dubiel, Mikołaj
Brons, Stephan
Stahl, Achim
Hetzel, Ronja
Opis:
Objective. The objective of the presented study was to evaluate the feasibility of a coded-mask (CM) gamma camera for real-time range verification in proton therapy, addressing the need for a precise and efficient method of treatment monitoring. Approach. A CM gamma camera prototype was tested in clinical conditions. The setup incorporated a scintillator-based detection system and a structured tungsten collimator. The experiment consisted of the irradiation of PMMA phantom with proton beams of energies ranging from 70.51 to 108.15 MeV. Experimental data were benchmarked against Monte Carlo simulations. The distal falloff position (DFP) was determined for both experimental data and simulations. Main results. The tested CM camera achieved a statistical precision of DFP determination of 1.7 mm for 108 protons, which is consistent with simulation predictions, despite hardware limitations such as non-functional detector pixels. Simulations indicated that a fully operational setup would further improve the performance of the detector. The system demonstrated rate capability sufficient for clinical proton beam intensities and maintained performance without significant dead time. Significance. This study validates the potential of the CM gamma camera for real-time proton therapy monitoring. The technology promises to enhance treatment accuracy and patient safety, offering a competitive alternative to existing approaches such as single-slit and multi-slit systems.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies