Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Mocko, M." wg kryterium: Autor


Wyświetlanie 1-10 z 10
Tytuł:
Neutron recognition in the LAND detector for large neutron multiplicity
Autorzy:
Łukasik, J.
Bassini, R.
Wieloch, Andrzej
Leray, S.
Orth, H.
Hellström, M.
Lynch, W. G.
Brzychczyk, Janusz
Boretzky, K.
Müller, W. F. J.
Otte, A. N.
Simon, H.
Salsac, M.-D.
Verde, G.
Johansson, H.
Pullia, A.
Trautmann, W.
Veselsky, M.
Emling, H.
De Napoli, M.
Mocko, M.
Wallace, M.
Le Gentil, E.
Boiano, C.
Volant, C.
Majka, Zbigniew
Boudard, A.
Henzlova, D.
Ducret, J. -E.
Zwiegliński, B.
Lynen, U.
Bianchin, S.
Lühning, J.
Wiechula, J.
Sfienti, C.
Schwarz, C.
Frankland, J. D.
Weick, H.
Pawłowski, P.
Mykulyak, A.
Immè, J.
Rossi, D.
Czech, B.
Tsang, M. B.
Panebianco, S.
Chbihi, A.
Aumann, T.
Iori, I.
Kupny, Sebastian
Le Fèvre, A.
Kezzar, K.
Rapisarda, E.
Leifels, Y.
Sümmerer, K.
Hlavac, S.
Raciti, G.
Bacri, C. O.
Lafriakh, A.
Adrich, P.
Barczyk, Tadeusz
Gorbinet, T.
Sann, H.
Palit, R.
Cibor, J.
Opis:
The performance of the LAND neutron detector is studied. Using an event-mixing technique based on one-neutron data obtained in the S107 experiment at the GSI laboratory, we test the efficiency of various analytic tools used to determine the multiplicity and kinematic properties of detected neutrons. A new algorithm developed recently for recognizing neutron showers from spectator decays in the ALADIN experiment S254 is described in detail. Its performance is assessed in comparison with other methods. The properties of the observed neutron events are used to estimate the detection efficiency of LAND in this experiment.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Badanie zużycia energii przez samochód elektryczny w czasie testów drogowych
Estimation of Energy Consumption of Electric Vehicle During Road Driving Test
Autorzy:
Moćko, W.
Ornowski, M.
Szymańska, M.
Tematy:
akumulatory trakcyjne
samochód elektryczny
zużycie energii
cykle jezdne
traction batteries
electric vehicles
energy consumption
driving cycles
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Powiązania:
https://bibliotekanauki.pl/articles/1368389.pdf  Link otwiera się w nowym oknie
Opis:
This work shows the results of energy consumption of electric vehicle estimated at three selected cases of car usage i.e. urban traffic, urban cycle with common stops forced by traffic lights and highway cycle. The tests were carried out using vehicle equipped with the asynchronic electric engine driven by the inwerter powered by the pack of lead-acid batteries. The unit energy consumption was within the range from 155 Wh/km to 223 Wh/km. The magnitude of energy consumption was strictly combined with driving fluency. The increase in stop/go cycles results in increase of energy consumed.
W pracy przedstawiono wyniki pomiarów zużycia energii w trakcie trzech wybranych przypadków korzystania z samochodu elektrycznego: jazdy w warunkach dużego natężenia ruchu, jazdy miejskiej z zatrzymaniami wymuszonymi przez sygnalizację świetlną oraz jazdy pozamiejskiej po drodze ekspresowej. Badania zostały przeprowadzone z użyciem samochodu wyposażonego w silnik asynchroniczny sterowany przez falownik, zasilany przez pakiet akumulatorów kwasowych. Jednostkowe zużycie energii wynosiło od 155 Wh/km do 223 Wh/km, przy czym wartość zużycia energii silnie zależała od płynności jazdy. Zwiększenie liczby cykli zatrzymania/ruszania powodowało wzrost energii pobieranej z akumulatorów.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opracowanie i kalibracja modelu matematycznego akumulatorów trakcyjnych przeznaczonych do samochodu elektrycznego
Development and Calibration of The Mathematical Model of Traction Batteries for Electric Car
Autorzy:
Moćko, W.
Szymańska, M.
Wojciechowski, A.
Tematy:
akumulatory trakcyjne
akumulatory litowo-jonowe
akumulatory VRLA
model akumulatora
traction batteries
lithium-ion battery
VRLA battery
battery model
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Powiązania:
https://bibliotekanauki.pl/articles/1368390.pdf  Link otwiera się w nowym oknie
Opis:
This paper presents the mathematical model of two types of batteries: VRLA (Valve Regulated Lead Acid) and lithium-ion batteries. The models allow for dynamic simulation of charging and discharging characteristics - determination of the output voltage for a wide range of currents and to determine the state of charge or discharge the battery, change the temperature of the cell volume and the number of cycles of use. The models were calibrated based on data from chassis dynamometer, which included the process of discharging the battery while driving at a constant speed and load from SOC = 0 to SOC=1 (SOC - state of charge), and based on manufacturer's data sheets.
W niniejszej pracy przedstawiono model matematyczny dwóch typów akumulatorów: VRLA (ang. Valve Regulated Lead Acid) oraz litowo-jonowych. Opracowane modele pozwalają na dynamiczną symulację charakterystyk ładowania i rozładowania – wyznaczanie napięcia wyjściowego dla szerokiego zakresu prądów oraz określenie stanu naładowania lub rozładowania akumulatora, zmiany pojemności ogniwa od temperatury i liczby cykli użytkowania. Modele zostały wykalibrowane na podstawie danych pochodzących z hamowni podwoziowej, które obejmowały proces rozładowania akumulatorów w trakcie jazdy ze stałą prędkością oraz ładowanie od wartości SOC = 0 do SOC = 1 (SOC – stan naładowania, ang. state of charge), a także na podstawie danych katalogowych producenta.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Properties and Structure of X30MnAlSi26-4-3 High Strength Steel Subjected to Dynamic Compression Processes
Autorzy:
Śmiglewicz, A.
Jabłońska, M.
Moćko, W.
Kowalczyk, K.
Hadasik, E.
Tematy:
high strength steel
dynamic compression
split Hopkinson bar
share bands
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/355215.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents the results of investigation on X30MnAlSi26-4-3 austenitic steel subjected to dynamic compression using the split Hopkinson pressure bar. The strain rate was 3700 s-1. The compression test was also carried out without the use of breaking rings and then true strain was about 0.3. The split Hopkinson pressure bar test take only few milliseconds to complete during which time it is impossible to transfer the excess heat out of the specimen, therefore the test must be carried out in adiabatic conditions and so the increase of the temperature caused by the work of plastic deformation had to be calculated. The stepping load method was used in order to evaluate the effect of adiabatic heating on the properties of steel which allowed to maintain the isothermal deformation conditions. The paper presents the comparison of results obtained during deformation under adiabatic and isothermal conditions in correlation to structure changes occurring in course of dynamic compression.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical simulation of dynamic weld compression
Autorzy:
Barnat, W.
Kordys, M.
Moćko, W.
Dybcio, P.
Panowicz, R.
Tematy:
Split-Hopkinson Pressure Bar
SHPB
welding
weld
Pokaż więcej
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Powiązania:
https://bibliotekanauki.pl/articles/247316.pdf  Link otwiera się w nowym oknie
Opis:
The article presents some numerical results and experimental validation of Split Hopkinson pressure bar (SHPB) tests for welded S40NL steel. The goal of this research is to define material constants for modelling it in FEM. Steel was tested with Charpy impact test to determine properties of material. Next, the joint for welding was prepared. It was welded with electric arc welding method (MAG) with flux-cored wire. Hopkinson bar test is well-known experiment method used to determine material properties at high strain rates. The tests were performed in Institute of Fundamental Technological Research. Material properties for Johnson-Cook material model were obtained. Comparison between experimental results taken in quasi-static conditions and dynamic conditions proves that the behaviour of materials in those two states is quite different. Results from one type of loading condition cannot be used to create a realistic model of material when it is loaded dynamically. Numerical simulation of Hopkinson bars was performed on cylindrical model with known length and accelerated to high speed in direction of incident bar. For the purpose of the simulation, a Finite Element Code LS-DYNA was used. It allows simulation of dynamic response of SHPB system. The results show quite good agreement. The model can be used to simulate weld performance under high strain rate.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of dislocation substructures in high-Mn steels after dynamic deformation tests
Autorzy:
Śmiglewicz, A.
Moćko, W.
Rodak, K.
Bednarczyk, I.
Jabłońska, M.
Tematy:
81.05.Bx
81.40.-z
68.37.Ma
46.70.-p
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1058094.pdf  Link otwiera się w nowym oknie
Opis:
The article presents the dynamic mechanical properties of two types of high manganese austenitic TWIP steels. The investigations were carried out for the wide range of strain rates from 10¯² s¯¹ up to 4×10³ s¯¹ using servo-hydraulic testing machine and split Hopkinson bar for the quasi-static and dynamic loading regime, respectively. The mechanical properties at different strain rates like yield strength and true stress were calculated out on the base of the results of impact tests. In the next step, the microstructure of the analyzed steels after different deformation rates were observed by scanning transmission electron microscopy technique in order to disclose a dislocation structures and mainly the TWIP effect. In the studies observed that with the strain rate increasing yield strength as well as true stress for 0.3 true strain increasing in both steels. The microstructure observations reveal the influence of strain rate on the structure evolution for analyzed steels.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Gold Nanolayer Properties Using X-Ray Reflectometry and Spectroscopic Ellipsometry Methods
Autorzy:
Stabrawa, I.
Banaś, D.
Dworecki, K.
Kubala-Kukuś, A.
Braziewicz, J.
Majewska, U.
Wudarczyk-Moćko, J.
Pajek, M.
Góźdź, S.
Tematy:
61.05.cm
62.23.St
68.55.-a
81.07.-b
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1398825.pdf  Link otwiera się w nowym oknie
Opis:
X-ray reflectometry and spectroscopic ellipsometry methods were applied for determination of physical properties of gold nonolayers. The nanolayers were prepared by sputtering of gold on different substrates: borosilicate glass, polished crystalline quartz and crystalline silicon. With X-ray reflectometry technique roughness of the substrates and density, thickness and roughness of gold layers were determined. The results showed decrease in density of the gold layers due to their nanometer thickness and that roughness of the underlayer affects roughness of the gold layer. In addition, thicknesses of the gold layers measured with spectroscopic ellipsometry turned out to be in agreement, within the experimental uncertainty, with results of the X-ray reflectometry method.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray Diffraction and Elemental Analysis of Medical and Environmental Samples
Autorzy:
Bielecka, K.
Kurtek, W.
Banaś, D.
Kubala-Kukuś, A.
Braziewicz, J.
Majewska, U.
Pajek, M.
Wudarczyk-Moćko, J.
Stabrawa, I.
Tematy:
78.70.En
87.64.Bx
32.30.Rj
87.64.kv
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1197663.pdf  Link otwiera się w nowym oknie
Opis:
The results of the elemental and chemical composition analysis of human medical samples (blood, serum, hair, urine, tooth, kidney stones, gallstones) and environmental samples (slag, cereal, vegetables, flour, pork bones, pork meat, fish) are presented. The analysis were performed by application of the total reflection X-ray fluorescence, wavelength dispersive X-ray fluorescence and X-ray powder diffraction methods. With X-ray fluorescence methods the following elements were identified: O, Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Se, Br, Rb, Sr, Zr, I, Ba, and Pb, whose concentrations were from a few ng/g to tens of percent. For some samples the elemental analysis was extended by X-ray powder diffraction measurements. With this method the chemical composition was determined. In the paper the experimental setups, methodology of samples preparation and methods of carrying out the measurements are described. As an example the X-ray spectra registered for gallstone sample are discussed in detail. Finally, the results of X-ray diffraction and elemental analysis for selected medical and environmental samples are summarized.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-Ray Fluorescence Techniques in Medical Applications: Reference Values of Elements in Human Serum, Urine and Hair
Autorzy:
Majewska, U.
Banaś, D.
Braziewicz, J.
Kubala-Kukuś, A.
Pajek, M.
Sychowska, I.
Wudarczyk-Moćko, J.
Antczak, G.
Borkowska, B.
Góźdź, S.
Tematy:
32.30.Rj
87.64.kd
87.64.kv
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1197643.pdf  Link otwiera się w nowym oknie
Opis:
The aim of undertaken long-term studies of the elemental composition of human serum, urine, and hair is to define reference values of elements concentration. For this purpose the total reflection X-ray fluorescence method was applied to determination of several elements concentration in human serum, urine and hair (S, K, Ca, Fe, Cu, Zn, Br, P, Cr, and Rb in serum samples; Fe, Cu, Zn, Rb, Cr, Mn, and Sr in urine samples; S, K, Ca, Fe, Cu, Br, Zn, Cl, Ti, Cr, Mn, Ni, and Se in hair samples) in the range of concentration from ppb to several hundred ppm. The method of selection of the control group, the experimental setup and its calibration procedure are described. We also present sample preparation methods and procedure of measurements.
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies