Analysis of Surface Plasmons in the Optical Planar Waveguide with Spectral Detection
Autorzy:
Opilski, Z.
Tematy:
73.20.Mf
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1506807.pdf  Link otwiera się w nowym oknie
Opis:
The paper deals with investigations concerning the plasmon resonance in an optical planar waveguide structure, applied in the construction of sensors with spectral detection. The surface plasmons in a multi-layer planar structure (with complex refractive indices) have been described, as well as the way of numerical solutions of physical equations describing the propagating electromagnetic field in such structures. The physical interpretation of obtained results has been presented, too.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Surface Plasmons in a Planar Waveguide System with Spectral Detection - Results of Model Investigations
Autorzy:
Opilski, Z.
Tematy:
73.20.Mf
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1506808.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents the results of numerical investigations of the phenomenon of plasmon resonance in a planar waveguide structure, applied in the construction of sensor with spectral detection.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Surface Plasmons in a Planar Waveguide System with Spectral Detection - Experimental Results
Autorzy:
Opilski, Z.
Tematy:
73.20.Mf
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1506820.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents the results of experimental investigations concerning the plasmon resonance in a planar waveguide structure applied in the construction of sensors with spectral detection.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spectropolarimetric analyses of optical single mode SU8 waveguide layers
Autorzy:
Gut, K.
Opilski, Z.
Tematy:
interferometry
SU8 optical waveguides
optical sensors
interferometria
czujniki optyczne
światłowody
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/200815.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents the principle of the operation of a spectropolarimetric interferometer. In a planar waveguide orthogonal modes of the TE and TM types can be excited for the entire visible light. During the propagation the difference of the phases between the modes was determined, which is the function of the length of the path of propagation, the difference of the effective refractive index (NTM-NTE) and the wavelength. At the output of this system the spectral distribution of intensity was recorded, the shape of which depends on the value of the refractive index of the cover of the waveguides.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of Partial Discharges in Generator Coil Bars with the Help of Calibrated Acoustic Emission Method
Autorzy:
Witos, F.
Gacek, Z.
Opilski, Z.
Tematy:
43.40.Le
43.60.Lg
52.80.s
77.22.Jp
84.70.+p
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1811569.pdf  Link otwiera się w nowym oknie
Opis:
Investigation results of acoustic emission signals coming from partial discharges within chosen generator coil bar, in relation to measurement results of apparent charge introduced by partial discharges sources, are presented in the article. Analysis is based on amplitude distributions calculated for acoustic emission signals, ordered at different measuring points for different values of the supply voltage. In order to assign acoustic emission signal to its advance degree a descriptor named by an acronym ADP (defined by authors) is calculated for each amplitude distribution. Descriptor families describing acoustic emission signals measured at particular measuring points (for different supply voltages) are presented in relation to apparent charge introduced by acoustic emission sources. These families concerning acoustic emission signals, measured at different measuring points for identical supply voltage, enable us to locate acoustic emission sources with maximum activity.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary Research Concerning Measurements οf the POLVAD Blood Chamber Volume Based οn Helmholtzs Acoustic Resonator Principle
Autorzy:
Konieczny, G.
Opilski, Z.
Pustelny, T.
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1493249.pdf  Link otwiera się w nowym oknie
Opis:
The article presents researches concerning a system for a possible blood volume measurements applied in POLVAD prosthesis. The proposed solution is based on the Helmholtz resonance principle. The article shows the state of art in blood volume sensors for using in the POLVAD prosthesis and introduces a newly proposed solution. The construction of the sensor and the results of static tests are presented. The work is summarized with future development plans.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Researches on the Spectral Transmittance of Zinc Oxide ZnO Semiconductor Layers
Autorzy:
Struk, P.
Pustelny, T.
Opilski, Z.
Tematy:
42.25.Hz
42.25.-p
42.82.Et
68.35.Ct
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1506851.pdf  Link otwiera się w nowym oknie
Opis:
The paper deals with investigations concerning a wide-band gap material, viz. zinc oxide ZnO. Special attention has been devoted to the determination of the spectral transmission of zinc oxide layers deposited on quartz substrates. These investigations have made it possible to determine the optical spectral range in which this material is transparent as well as the edges of absorption. The presented investigations are valuable particularly concerning the application of zinc oxide in optoelectronic and photonic structures as well as in systems of waveguides and sensor layers of integrated optics.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
State of the Work Diagram of the Artificial Heart
Autorzy:
Konieczny, G.
Opilski, Z.
Pustelny, T.
Maciak, E.
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/1807734.pdf  Link otwiera się w nowym oknie
Opis:
This paper presents the results of investigations on novel pressure measurement methods to be for used in the project "Polish Artificial Heart". The investigations concerned possible pressure sensors for noninvasive blood pressure measurements in selected points around the pneumatic ventricular assist device (POLVAD). The fiber pressure sensor and the possibility of pressure measurements with piezofoils were tested. The paper includes preliminary results and development plans.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielokanałowy, optoelektroniczny system do pomiaru stężenia gazów
The multichannel, optoelectronic gas sensor system based on interferometric nanostructures with gasochromic thin films
Autorzy:
Maciak, E.
Opilski, Z.
Pustelny, T.
Urbańczyk, M.
Tematy:
optyczny czujnik gazu
optoelektroniczny system pomiarowy
nanostruktura sensorowa
optical gas sensor
optoelectronic gas sensor system
sensing nanostructure
optical interferometric structure
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/154779.pdf  Link otwiera się w nowym oknie
Opis:
W pracy przedstawiono nowatorski wielokanałowy, optoelektroniczny system pomiarowy i sposób pomiaru stężenia gazów przemysłowych i toksycznych. Mierzony analit gazowy może być różny w zależności od zastosowanej interferencyjnej nanostruktury sensorowej. Pomiar odbywa się w gazowym środowisku pomiarowym. Niniejsze rozwiązanie optoelektronicznego, gazowego systemu pomiarowego wykorzystuje interferencyjne, optyczne nanostruktury sensorowe zawierające w swej konstrukcji cienkie warstwy receptorowe z optycznie czynnych materiałów. Zatem, optyczna głowica sensorowa zmienia swoje parametry optyczne w wyniku oddziaływania z badanym analitem gazowym.
In the paper the multichannel, optoelectronic gas sensor system based on interferometric, gasochromic nanostructures is presented. The silicon colour sensor TCS230 detects the intensity and change of colour coordinates RGB of an optical signal resulting from exposure of the sensing structure to a specific type of gas. Using multichannel measurement, one can simultaneously detect different gas or analyte molecules in the sample by immobilizing different optical receptor thin films (nanostructures) at different channels. Each optical sensing channel consists of three parts: the input port which includes a broadband light source: "warm" white LED, multi-layered sensing nanostructure: interferometric and gasochromic, the output port including a silicon colour sensor TCS230 detecting the intensity and change of colour coordinates RGB of an optical signal resulting from the sensing structure exposure to a specific type of gas. At the sensing window, on the glass substrate there are immobilized nanostructures being chemo-optical, gasochromic and interferometric transducer receptors, which can selectively interact with a specific type of gas molecules present in the gas mixture. When a physical-chemical binding process takes place on the sensing window of the measuring channel, an interferometric colour of the sensing element (nanostructure) changes and colour coordinates of the measured optical signal change as well. The change of the colour coordinates is proportional to the change of the effective refractive index of the receptor structure (particularly refractive index of the resonance cavity). By measuring the intensity change of the optical signal RGB, the refractive index change ?n taking place in the measuring window can be calculated and the concentration of a specific gas in the gas mixture can be measured.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic System of Determining the Instantaneous Volume of the Blood Part of the Ventricular Assist Device POLVAD-EXT
Autorzy:
Konieczny, G.
Pustelny, T.
Opilski, Z.
Gawlikowski, M.
Tematy:
acoustic Helmholtz’s
resonator
blood volume estimation
VAD
ventricular assist device
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/176599.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents the results of investigations concerning the noninvasive method of estimating the actual volume of the blood chamber of the POLVAD-EXT type ventricular assist device (VAD) during its operation. The proposed method is based on the principle of Helmholtz’s acoustic resonance. Both the theory, main stages of the development of the measurement method as well as the practical implementation of the proposed method in the physical model of the POLVAD-EXT device are dealt with. The paper contains the results of static measurements by means of the proposed method (conducted at the Department of Optoelectronics, Silesian University of Technology) as well as the dynamic measurements taken at the Foundation of Cardiac Surgery Development (Zabrze, Poland) with the professional model of the human cardiovascular system. The results of these measurements prove that the proposed method allows to estimate the actual blood chamber volume with uncertainties below 10%.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies