Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ott, F." wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
Interlayer Exchange Coupling in Short Period GaMnAs/GaAs Superlattices
Autorzy:
Szuszkiewicz, W.
Dynowska, E.
Hennion, B.
Ott, F.
Jouanne, M.
Morhange, J. F.
Karlsteen, M.
Sadowski, J.
Tematy:
61.12.-q
75.25.+z
78.30.Fs
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/2027487.pdf  Link otwiera się w nowym oknie
Opis:
The low dimensional structures containing III-V ferromagnetic semiconductors were intensively investigated in the last few years because of the variety of their potential applications. The aim of the present work was to study the interlayer exchange coupling in the short period GaMnAs/GaAs superlattices containing 16 or 8 GaMnAs monolayers. Samples with the magnetic layers corresponding to the mixed crystal composition with 5% or 6% of Mn were grown by MBE technique and characterized by both high-resolution X-ray diffraction and Raman scattering methods. Folded acoustic phonons were observed for the first time for this particular quantum system in the Raman scattering spectra. The interlayer exchange coupling in selected superlattices was investigated by both elastic neutron scattering (diffraction) and polarized neutron reflectivity measurements. Presence of the smooth interfaces and the stability of the superlattice period were confirmed by neutron reflectometry data. Ferromagnetic correlation of the magnetization vector in subsequent GaMnAs magnetic layers was demonstrated by both experimental methods.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka środowisk depozycyjnych Jeziora Czechowskiego i jego otoczenia
Characteristics of depositional environments of Czechowskie Lake basin and its vicinity
Autorzy:
Kordowski, J.
Błaszkiewicz, M.
Kramkowski, M.
Słowiński, M.
Tyszkowski, S.
Brauer, A.
Brykała, D.
Gierszewski, P.
Lamparski, P.
Lutyńska, M.
Mirosław-Grabowska, J.
Noryśkiewicz, A.M.
Obremska, M.
Ott, F.
Wulff, S.
Zawiska, I.
Tematy:
martwy lód
misa jeziorna
analiza sedymentologiczna
Pojezierze Starogardzkie
dead ice
lake basin
sedimentological analysis
Starogard Lakeland
Pokaż więcej
Wydawca:
Stowarzyszenie Geomorfologów Polskich
Powiązania:
https://bibliotekanauki.pl/articles/294338.pdf  Link otwiera się w nowym oknie
Opis:
W artykule przedstawiono przegląd badań nad morfogenezą misy jeziornej Jeziora Czechowskiego na Pojezierzu Starogardzkim. W dostępnych odsłonięciach, wkopach i wierceniach o nienaruszonej strukturze przeprowadzono analizę sedymentologiczną osadów glacjofluwialnych, glacjolimnicznych, limnicznych i stokowych. Wyniki tej analizy uzupełniono rezultatami kartowania geologicznego i geomorfologicznego. W efekcie przeprowadzonych prac stwierdzono, że misa jeziora założona jest w głębokiej rynnie subglacjalnej, która do początku allerødu zakonserwowana była bryłami martwego lodu. Ich wytopienie doprowadziło do powstania zróżnicowanej morfologii dna rynny. W najgłębszych miejscach, dzięki ograniczonej miksji, były warunki do zachowania rocznej laminacji osadów dennych. Sedymentacja osadów glacjofluwialnych w otoczeniu rynny była bardzo zróżnicowana i w wielu miejscach wskazuje na warunki przepływu nadkrytycznego. W przypowierzchniowej warstwie osadów sandrowych stwierdzono ślady zapisu procesów mrozowych (gleby mrozowe) oraz wytrącenia węglanowe wskazujące na występowanie warunków peryglacjalnych po zaprzestaniu przepływu proglacjalnego. Osady limniczne są również zróżnicowane w zależności od cech morfometrycznych basenu sedymentacyjnego, a przede wszystkim od głębokości ich depozycji. Osady stokowe pochodzą w większości z ostatnich dwustu lat, a ich depozycja nastąpiła wskutek działalności gospodarczej człowieka.
The paper aims to review the investigations on the genesis of the Czechowskie Lake basin (Starogard Lakeland, north-central Poland). The sedimentological analysis of the glaciofluvial, glaciolimnic, limnic and colluvial deposits have been conducted in the outcrops, pits and boreholes with undisturbed cores. They were supplemented by the results of the geological and geomorphological mapping. Summing up the investigations it can be stated that the lake basin developed within a deep subglacial channel which was preserved by the dead ice blocks till the onset of the Allerød. Their melting led to the emergence of a morphologically diversified lake basin. The conditions in its deepest parts, due to hampered mixing and wave action, favoured the preservation of the annually laminated sediments. The glaciofluvial deposition in the vicinity of the lake was diverse and in many places it indicates the supercritical condition of the water flow. Within the near-surface layer of outwash deposits were recognized the traces of the periglacial processes and calcareous precipitates which indicate short glaciolimnic periods or breaks in sedimentation. The limnic sediments are also diversified and dependent on the morphometric features of the sedimentary basin, mostly the depth of the deposition. Colluvial deposits have originated mostly in the last 200 years as a consequence of the transient deforestation of the surrounding area.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of electromagnetic calorimeter concept for the HADES spectrometer
Autorzy:
Koenig, W.
Rodríguez-Ramos, P.
Galatyuk, T.
Pietraszko, J.
Sobolev, Y. G.
Guber, F.
Czyžycki, W.
Otte, P.
Blume, C.
Petukhov
Golubeva, M.
Kardan, B.
Lapidus, K.
Fabbietti, L.
Kajetanowic, M.
Thomas, A.
Lisowski, E.
Linev, S.
Epple, E.
Skott, P.
Kugler, A.
Ott, P.
Reshetin, A.
Salabura, Piotr
Svoboda, O.
Rost, A.
Steffen, O.
Traxler, M.
Tlustý, P.
Ivashkin, A.
Hlaváč, S.
Opis:
The HADES spectrometer currently operating on the beam of SIS18 accelerator in GSI will be moved to a new position in the CBM cave of the future FAIR complex. Electromagnetic calorimeter (ECAL) will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 A GeVon the beam of the new accelerator SIS100. Calorimeter will be based on 978 massive lead glass modules read out by photomultipliers and a novel front-end electronics. Secondary gamma beam with energies ranging from 81 MeV up to 1399 MeV from MAMI-C Mainz facility was used to verify selected technical solutions. Relative energy resolution was measured using modules with three different types of photomultipliers. Two types of developed front-end electronics as well as energy leakage between neighbouring modules under parallel and declined gamma beams were studied in detail.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Inne
Tytuł:
Electromagnetic calorimeter for HADES experiment
Autorzy:
Reshetin, A.
Golubeva, M.
Sobolev, Y. G.
Traxler, M.
Guber, F.
Kajetanowicz, Marcin
Linev, S.
Neiser, A.
Kardan, B.
Koenig, W.
Ott, O.
Salabura, Piotr
Fabbietti, L.
Tlusty, P.
Rodríguez-Ramos, P.
Lisowski, E.
Pietraszko, J.
Svoboda, O.
Hlaváč, S.
Pethukov, O.
Korcyl, Grzegorz
Lapidus, K.
Chlad, L.
Galatyuk, T.
Kugler, A.
Rost, A.
Thomas, A.
Otte, O.
Ivashkin, A.
Epple, E.
Opis:
Electromagnetic calorimeter (ECAL) is being developed to complement dilepton spectrometer HADES. ECAL will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 AGeV on the beam of future accelerator SIS100@FAIR. We will report results of the last beam test with quasi-monoenergetic photons carried out in MAMI facility at Johannes Gutenberg Universität Mainz.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Inne
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies