Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Capacitance" wg kryterium: Temat


Tytuł:
Investigation on silicon solar cell capacitance and its dependence on both temperature and incidence angle
Autorzy:
Sané, M
Barro, F I
Tematy:
vertical junction
capacitance
temperature
incidence angle
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/102664.pdf  Link otwiera się w nowym oknie
Opis:
The aim of this work is to investigate a theoretical study of a vertical junction silicon solar cell capacitance under monochromatic illumination. By solving the continuity equation and using a one dimensional model in frequency modulation, we derive the analytical expressions of both excess minority carrier density and photovoltage. Based on these expressions, the solar cell capacitance was calculated; we then exhibited the effects of both temperature and incidence angle on the solar cell capacitance.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of electrical capacitance tomograph design in the nuclear and medical electronics division
Rozwój konstrukcji elektrycznego tomografu pojemnościowego w zakładzie elektroniki jądrowej i medycznej
Autorzy:
Kryszyn, J.
Smolik, W.
Olszewski, T.
Szabatin, R.
Tematy:
electrical capacitance tomography
elektryczna tomografia pojemnościowa
Pokaż więcej
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Powiązania:
https://bibliotekanauki.pl/articles/408376.pdf  Link otwiera się w nowym oknie
Opis:
Electrical Capacitance Tomography is a technique which allows to visualize a spatial distribution of electric permittivity in an examined volume. ECT allows to achieve hundreds of frames per second which is suitable for the industrial application, e.g. monitoring of multiphase flows or material mixing. Construction of such ECT system which enables precise data acquisition with sufficient speed is a challenge. In the Division of Nuclear and Medical Electronics ECT systems which have found applications in many research facilities in Poland and all over the world have been constructed for over 15 years. In this article a multichannel ET3 tomograph and its successor,EVT4, are presented. EVT4 will allow to obtain more than 10 thousand frames per second. This will allow to make progress in studies of dynamic processes and 3D visualization.
Elektryczna tomografia pojemnościowa pozwala na obrazowanie przestrzennego rozkładu przenikalności elektrycznej w badanej objętości. Technika ta pozwala na uzyskanie setek obrazów na sekundę, dzięki czemu istnieje możliwość wykorzystania jej w przemyśle, na przykład do monitorowania procesów dynamicznych, takich jak przepływy wielofazowe lub mieszanie materiałów. Skonstruowanie systemu tomograficznego pozwalającego na bardzo szybką akwizycję obrazów o dobrej jakości jest jednak dużym wyzwaniem. W Zakładzie Elektroniki Jądrowej i Medycznej Politechniki Warszawskiej od lat powstają konstrukcje tomografów pojemnościowych, które znajdowały zastosowanie w placówkach naukowych w Polsce i na świecie. W tym artykule prezentowany jest wielokanałowy tomograf ET3 oraz jego następca, EVT4, który pozwoli na uzyskiwanie 10 tysięcy obrazów na sekundę. Pozwoli to na dokładniejsze badanie procesów dynamicznych oraz wizualizację trójwymiarową.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of TJ and ITO GaN VCSELs in terms of their frequency characteristics
Autorzy:
Śpiewak, Patrycja
Wasiak, Michał
Sarzała, Robert P.
Tematy:
VCSELs
nitride
capacitance phenomena
computer modelling
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Powiązania:
https://bibliotekanauki.pl/articles/59112929.pdf  Link otwiera się w nowym oknie
Opis:
The work focuses on vertical cavity surface emitting lasers (VCSELs) made of nitride materials that emit a wavelength of 445 nm. Two structures were examined: a laser with a tunnel junction and implantation (TJ VCSEL) and an ITO contact (ITO VCSEL). The analysis delves into capacitance phenomena influencing the modulation speed of these lasers. The results highlight differences in active currents between two structures, i.e., currents which contribute to the modulation of the laser emission. According to the authors’ simulations, the TJ VCSEL is more effective in modulating the number of carriers in the active region than the ITO VCSEL, assuming the same modulation amplitude of driving current.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekcja funkcji przetwarzania czujnika stosowanego w tomografii pojemnościowej
Systematic error correction in capacitance tomography
Autorzy:
Rząsa, R. M.
Tematy:
tomograf pojemnościowy
korekcja błędu
pomiar pojemności
pomiar przypływu
Capacitance tomograph
error correction
measurement of capacitance
measurement of flow
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/152781.pdf  Link otwiera się w nowym oknie
Opis:
Tomografia procesowa coraz częściej znajduje zastosowanie w badaniach eksperymentalnych różnych procesów przemysłowych. Jednym z rozwiązań jest tomograf pojemnościowy. Niejednokrotnie jest on wykorzystywany do badania przepływów dwufazowych. Początkowo tomografy były stosowane do wyznaczania obrazu struktury przepływu. Obecnie tomograf może być przyrządem pomiarowym który poza wyświetleniem obrazu struktury może wyznaczyć podstawowe parametry opisujące proces. Aby było możliwe dokonanie pomiarów konieczne jest odpowiednie wzorco-wanie urządzenia. Na wynik pomiaru ma wpływ szereg pojemności, pochodzących od elementów znajdujących się w bezpośrednim sąsiedztwie elektrod pomiarowych. Ze względu na budowę tomografu pewne błędy są nieuniknione. W celu zredukowania ich wpływu zaproponowano metodę korekcji funkcji przetwarzania dla typowego czujnika tomografu pojemnościowego. W pracy przedstawiono podstawy teoretyczne i wyniki badań eksperymentalnych. Niniejsze opracowanie może mieć również zastosowanie w innych urządzeniach pomiarowych, których zasada działania oparta jest na pomiarze małych zmian pojemności.
Processing tomography is more and more often applied to tests of various industrial processes. The capacitance tomograph is one of measuring systems often used for tests of two-phase flows. Tomographs were previously used for determination of the flow structure images. At present they can be measuring devices which not only express the structure image but can be used for calculations of the basic parameters describing the process. In order to take measurements, it is necessary to calibrate the tomograph. Capacitances of elements being close to the measurement electrodes influence the measurement results. Some errors cannot be avoided. Thus, the correction method was proposed for measurements with the capacitance tomograph. The paper presents the theoretical basis and the test results obtained with this method. This method can also be used in other measuring devices for measurements of small capacitance changes.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of capacitance of a cryogenic by-pass line for SIS100 particle accelerator at FAIR
Autorzy:
Tomków, Ł.
Trojanowski, S.
Ciszek, M.
Chorowski, M.
Tematy:
line capacitance
superconducting bus-bars
particle accelerators
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/140368.pdf  Link otwiera się w nowym oknie
Opis:
Safety and operation efficiency of the particle accelerators strongly depend on the quality of the supplied electric current and is affected by the electric properties of all elements of the circuit. In this paper the capacitance of the superconducting bus-bars applied in the cryogenic by-pass line for the SIS100 particle accelerator at FAIR is analysed. The unit capacitance of the bus-bars is calculated numerically and found experimentally. A 2D numerical model of a cross-section of the cable is applied. The capacitance is found with three methods. The stored energy, electric displacement field and charge gathered on the surfaces of the device are calculated and analysed. The obtained values are consistent. Experimental measurements are performed using the resonance method. The measuring system is undamped using a negative conductance converter. Small discrepancies are observed between numerical and experimental results. The obtained values are within the requirements of the accelerator design.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical model of capacitance-related phenomena in semiconductor lasers based on partial differential equations
Autorzy:
Wasiak, Michał
Sarzała, Robert P.
Tematy:
capacitance
finite element methods
semi-conductor lasers
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Powiązania:
https://bibliotekanauki.pl/articles/59112956.pdf  Link otwiera się w nowym oknie
Opis:
This paper presents a model of the capacitance and electrical properties of semiconductor lasers biased with modulated voltage. The model is based on the finite-element method (FEM), which is widely used in computer modelling and is a natural generalisation of a wellknown constant-voltage FEM electrical model. In principle, the model can be applied to any kind of device where inductance can be neglected. Here, it is applied to simulate the complex impedance and other high-frequency electrical properties of a vertical-cavity surface-emitting laser. These properties are very important for the application of such lasers in optical data transfer systems. The results show that both the diameter of the top mesa and the surface area of the top electrical contact have a strong impact on the performance of the laser. This impact is analysed as a function of the modulation frequency.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu filtru pojemnościowego na kształt napięcia w węźle zasilającym
Analysis of the influence of a capacitance filter on the voltage waveform distortion in a supply node
Autorzy:
Szymańska, A.
Tematy:
jakość energii
filtry pojemnościowe
power quality
capacitance filters
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/153345.pdf  Link otwiera się w nowym oknie
Opis:
W celu zmniejszenia tętnień napięcia wyprostowanego stosowane są filtry pojemnościowe. W artykule przedstawiono wyniki analizy napięcia w węźle, z którego są zasilane: odbiornik przez prostownik z filtrem pojemnościowym oraz inne odbiorniki zasilane napięciem przemiennym. Przy wykorzystaniu autorskiego programu wyznaczono przebieg napięcia oraz jego widmo amplitudowe dla przyjętych wartości współczynnika tętnień. Dla wybranego okresu w stanie ustalonym przedstawiono zależność amplitud wybranych harmonicznych od pojemności filtru, wyznaczonej przez wymaganą wartość współczynnika tętnień.
A pulsatory voltage is generated at the rectifier output. Capacitance filters are often used in order to lower the voltage pulsation. There was determined the voltage amplitude change in time in the node from which a load is supplied through a rectifier with the capacitance filter (Fig. 1) [2]. The program written in the Matlab environment was used for it. For the selected voltage period in the steady state, there was determined the voltage amplitude spectrum for different values of the voltage pulsation factor at the rectifier output (Figs. 2 and 3). The developed program also allows calculating the timing of changes in the rectifier operating status. The analysed period of voltage changes in time was divided into subperiods corresponding to the consecutive cycles of charging and discharging the filter capacitor, during which the voltage in the supply node could be described by the equation (2) or (3). Using the equations (6) and (7), the amplitudes of each harmonic for the given circuit parameters were calculated and their dependence on the voltage pulsation factor at the rectifier output was determined (Figs. 5, 6, 7, 8). The presented equations and analysis results enable selecting the appropriate parameter values already at the stage of circuit design, so that the proper voltage quality is provided.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podniesiona cosinusoida jako rozkład gęstości prawdopodobieństwa - właściwości i przykłady zastosowań
Shifted up cosine as probability density function - properties and application examples
Autorzy:
Korczyński, M. J.
Warsza, Z. L.
Tematy:
wzorcowanie
indukcyjność
pojemność
calibration
inductance
capacitance
RLC comparator
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/157802.pdf  Link otwiera się w nowym oknie
Opis:
Omówiono niekonwencjonalny rozkład gęstości prawdopodobieństwa (PDF) w postaci jednego okresu cosinusoidy przesuniętej w górę i o polu równym 1 jako alternatywę rozkładu Normalnego (funkcji Gaussa). Wykazano, że w przedziale š2,5 odchylenia standardowego cosinusoida przesunięta o jej amplitudę A - funkcja 2Acos2(•), nie odbiega od rozkładu Normalnego więcej niż o š2,1%. Dla rzeczywistych wyników pomiarów o ograniczonym zakresie rozrzutu uzyskuje się mniejszą niepewność typu A niż według międzynarodowego Przewodnika GUM. Rozważania teoretyczne i symulacje poparto przykładem z praktyki metrologicznej. Rozkład COS2 można z powodzeniem stosować do szybkiego szacowania niepewności pomiarów, w tym do automatyzacji tych obliczeń oraz w statystyce.
Unconventional probability density distribution function (PDF) of the form of the one period of cosine function shifted up and of its area under curve equal of 1 is proposed as an alternative to Normal distribution, i.e. Gauss function. It is presented that if a cosine function is shifted up by its amplitude A, such function (2Acos2(•)), can be applied as approximation of the central part of Normal PDF (š2,5 of its standard deviation) with the accuracy not lower then 2,1%. In reality the distribution of measurements is always of limited range and uncertainty type A obtained by COS2 PDF is smaller than recommended by international Guide GUM [1]. Analysed data from experiment and simulated data confirmed that new proposed unconventional distribution has an advantage of a lowering uncertainty interval by comparison to Gaussian distribution at the same level of confidence, and calculations are simpler and faster. COS2 distribution can be successfully applied for the fast uncertainty evaluation of measurements, for its automation and in statistics.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement system for determination of supercapacitor equivalent parameters
Autorzy:
Kopka, R.
Tarczyński, W.
Tematy:
supercapacitor
measurement system
equivalent series resistance
equivalent capacitance
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/221574.pdf  Link otwiera się w nowym oknie
Opis:
In this paper a measurement system for determination of supercapacitor equivalent parameters is proposed. Specific properties of materials used for supercapacitor construction require some advanced tools and measurement procedures to be applied during tests. The measurement system allows to measure values of equivalent parameters by both the DC and AC method whilst keeping appropriate time criteria required by this type of devices. Furthermore, in this paper the most relevant properties and measurement capabilities of the proposed system are described as well as some exemplary values of the supercapacitor equivalent parameters measured experimentally are presented.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Self and mutual capacitance of conductors in air and lossy earth with application to electrified railways
Autorzy:
Mariscotti, Andrea
Tematy:
capacitance
electromagnetic coupling
electrified rail systems
electromagnetic modeling
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/141754.pdf  Link otwiera się w nowym oknie
Opis:
The problem of a closed-form accurate determination of self and mutual capacitance of conductors in air and earth is considered: the application is the complete modeling of a railway line including buried conductors. The Generalized Potential Method (GPM) is presented and analyzed with regard to conditions of validity and solution methods. The accuracy of the GPM is evaluated solving some reference cases using the Complex Image Method and a commercial Finite Element Method simulator, comparing the model results with experimental data, and including the sensitivity on soil conductivity and permittivity, distance of conductors from the air–earth interface and frequency.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies