Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Euler-Lagrange’a system" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Model matematyczny dwuprzewodowej linii zasilania z wykorzystaniem modyfikowanej zasady Hamiltona
Mathematical model of the double conductor power line using a modified Hamilton’s principle
Autorzy:
Czaban, A.
Lis, M.
Sosnowski, J.
Lewoniuk, W.
Tematy:
zasada Hamiltona-Ostrogradskiego
Euler-Lagrange’a system
zespół elektryczny
Hamilton-Ostrogradsky’s principle
Euler-Lagrange’s system
electrical set
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Powiązania:
https://bibliotekanauki.pl/articles/1200804.pdf  Link otwiera się w nowym oknie
Opis:
In the paper a mathematical model of an electric power system is presented. The system consists of double-circuit power line (Lecher’s line with distributed parameters) and active-inductive load circuit. The model was formulated on the basis of the generalized interdisciplinary method using the modified Hamilton’s principle with extended Lagrange’s function. Numerical calculations based on the formulated model have been made and results of computer simulations as graphs are presented in the paper.
W pracy, na podstawie uogólnionej interdyscyplinarnej metody wykorzystującej modyfikację zasady Hamiltona z uwzględnieniem rozszerzenia funkcji Lagrange’a sformułowano model matematyczny układu elektroenergetycznego, który składa się z dwuprzewodowej linii zasilania (linia Lechera o parametrach rozłożonych) i obciążenia o charakterze czynno-indukcyjnym. Na podstawie sformułowanego modelu przeprowadzono obliczenia numeryczne. Wyniki symulacji komputerowych przedstawiono w postaci graficznej.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model matematyczny generatora wiatrowego z wariatorem przy asymetrycznym obciążeniu R-L
Mathematical model of electric power generator with variator driven by wind turbine and loaded by unbalanced three-phase circuit RL
Autorzy:
Czaban, A.
Lis, M.
Klatow, K.
Sosnowski, J.
Gastołek, A.
Tematy:
zasada Hamiltona
Euler-Lagrange’a system
zespół elektryczny
system nieholonomiczny
Hamilton’s principle
Euler-Lagrange’s system
electrical set
nonholonomic systems
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Powiązania:
https://bibliotekanauki.pl/articles/1367333.pdf  Link otwiera się w nowym oknie
Opis:
In the paper a general mathematical model of an electric power system is formulated. The system consists of asynchronous generator, variator an unbalanced three-phase resistive-inductive load circuit. State equations in Cauchy’s standard form are given. A numerical analysis of transient processes, occurring in the investigated object, was carried out. The flexibility of motion transmission in electromechanical system is taken into account. The energy approaches for were used in order to formulate the differential equations.
W pracy, sformułowano ogólny model matematyczny zespołu elektroenergetycznego składającego się z generatora asynchronicznego, wariatora oraz asymetrycznego obciążenia RL. Równania stanu zapisano w postaci normalnej Caushego. Przeprowadzono analizę numeryczną procesów nieustalonych zachodzących w badanym obiekcie. Układ elektromechaniczny uwzględnia podatność transmisji ruchu. Do sformowania różniczkowych równań stanu wykorzystano podejścia energetyczne dla układów nieholonomicznych.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification and modelling of blood flow processes in section of large blood vessel using hybrid Euler-Lagrange multiphase approach
Identyfikacja oraz modelowanie procesu przepływu krwi w części dużego naczynia krwionośnego z wykorzystaniem wielofazowego modelu hybrydowego Euler-Lagrange
Autorzy:
Knopek, Artur
Tematy:
aorta
CFD
blood flow
Ansys Fluent
multiphase
DPM
przepływ krwi
ANSYS Fluent
Euler-Lagrange’a system
Euler-Euler
Wielofazowy Model Eulera
Pokaż więcej
Wydawca:
Politechnika Śląska. Wydział Inżynierii Środowiska i Energetyki. Instytut Techniki Cieplnej
Powiązania:
https://bibliotekanauki.pl/articles/101676.pdf  Link otwiera się w nowym oknie
Opis:
Computational fluid dynamics (CFD) in past known only in highly specialized technical engineering branch is nowadays one of main engineering tool in solving numerous complex problems in order to get crucial information and extend general knowledge in many fields. CFD allows to create new, more advanced systems and also optimize already created to enhance efficiency and/or reduce costs of production and operating. Actual situation demands from engineers to face difficult competition - fighting for minor fractions of efficiency due to construction and materials limitations. That operations do not concentrate only on that obvious disciplines like heat transfer, fluid dynamics or power-generation, but also new uncharted areas like automotive, chemical, aerospace, environmental engineering etc. One of that innovative field of CFD application is bio-engineering. In medicine, computer simulations can provide necessary, life-saving information with no interfere in patient body (in vivo), that allows to avoid later complications, application collisions and dangerous unpredictable after-effects. What more in several cases, in vitro analyses cannot be used through to life threats of treatment. The main objective of current project is to develop and test novel approach of accurate modelling of human blood flow in arteries. Currently available research reports do not cover the spatial interaction of individual blood phases and walls of blood vessels. Such approach could significantly reduce accuracy of such models. Proper simulations enriches general knowledge with specific details which could be crucial in early diagnosis of potential cardiac problems showing vulnerable zones (e.g. narrowed blood vessels). Such precise information are extremely difficult to obtain experimentally. Apart from multiphase concept of the project (that is considering every component of blood as separate phase assigning exceptional properties to each of them and determines relations between them) special attention was paid to the realism of geometry - considering the real system of the aortic segment (part of ascending aorta, aortic arch and part of thoracic aorta) including bifurcations. In addition a pulsating blood flow is being considered and implemented using built in UDF (User Defined Function) functionality of CFD code.
Obliczeniowa mechanika płynów (ang. CFD – Computational Fluid Dynamics) znana niegdyś tylko w wysoce wyspecjalizowanej technicznie branży jest jednym z podstawowych narzędzi inżynieryjnych w rozwiązywaniu wielu złożonych problemów, celem zdobycia kluczowych informacji i poszerzenia wiedzy ogólnej w wielu dziedzinach. CFD pozwala na tworzenie nowych, bardziej zaawansowanych systemów oraz na udoskonalanie już istniejących – poprawiając ich wydajność i/lub obniżając koszty produkcji oraz eksploatacji. Aktualna sytuacja wymaga od inżynierów zmierzenia się w trudnej dyscyplinie – walce o ułamki wydajności z powodu ograniczeń materiałowych i konstrukcyjnych. Przedsięwzięcia te nie koncentrują się jedynie na oczywistych dyscyplinach, takich jak przepływ ciepła, mechanika płynów czy wytwarzanie energii, ale także na nowych, niezbadanych sferach jak inżynieria motoryzacyjna, chemiczna, kosmiczna czy środowiska itd. Jednym z innowacyjnych zastosowań CFD jest bio-inżynieria. W medycynie, symulacje komputerowe są w stanie dostarczyć niezbędnych, nierzadko ratujących życie informacji, bez ingerencji w ciało pacjenta (in vitro), co pozwala uniknąć późniejszych komplikacji, zagrożeń występujących w trakcie wprowadzania przyrządów w ciało pacjenta czy niebezpiecznych nieprzewidywalnych powikłań. Ponad to w wielu przypadkach metody in vivo są niemożliwe do zastosowania ze względu na zagrożenie życia pacjenta. Głównym celem powyższego projektu było stworzenie i testy innowacyjnego, dokładnego modelu przepływu krwi w ludzkiej aorcie. Aktualnie dostępne badania nie uwzględniają przestrzennych interakcji pomiędzy poszczególnymi fazami krwi i ścianami naczyń krwionośnych. Takie podejście zdecydowanie zmniejsza dokładność tego typu modeli. Odpowiednie badania wzbogacają wiedzę ogólną o dokładne informacje , które mogą okazać się kluczowe we wczesnym diagnozowaniu problemów układu sercowo-naczyniowego, wskazując na potencjalnie podatne obszary (np. kurczące się naczynia krwionośne). Tak dokładne informacje są trudno dostępne do uzyskania na drodze badań. Poza wielofazowa koncepcją projektu, który rozpatruje każdy komponent krwi jako oddzielną fazę, przyporządkowując poszczególne właściwości do każdej z nich i uwzględniając ich wzajemne relacje, szczególną uwagę zwrócono na realistykę geometrii – zakładając rzeczywisty układ aortalny (część aorty wstępującej, łuk aortalny i część aorty zstępującej) uwzględniający bifurkację. Ponadto wprowadzono do modelu przepływ pulsacyjny za pomocą wbudowanej wewnętrznej funkcji programu. (ang. UDF – User Defined Function).
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An efficient fault tolerant control scheme for Euler-Lagrange systems
Autorzy:
Leal-Leal, Ivon E.
Alcorta-Garcia, Efrain
Tematy:
cascade structure
Euler-Lagrange system
FTC scheme
GPI observer based controller
struktura kaskadowa
system Eulera-Lagrange'a
schemat FTC
obserwator GPI
Pokaż więcej
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Powiązania:
https://bibliotekanauki.pl/articles/11542698.pdf  Link otwiera się w nowym oknie
Opis:
Every closed-loop system holds a level of fault tolerance, which could be increased by using a fault tolerant control (FTC) scheme. In this paper, an efficient FTC scheme for a class of nonlinear systems (Euler-Lagrange ones) is proposed, which guarantees high performance and stability in a faulty system. This scheme was designed on the basis of a cascade control structure in which the inner loop is the closed-loop system and the external loop is the FTC, a generalized proportional integral (GPI) observer-based controller, which manages the fault tolerance level increment. An important issue of the proposed scheme is that the GPI observer-based controller jointly estimates disturbances and faults, providing information about the state of health of the system, and then compensates their effect. The scheme is efficient because only the inertia matrix is required for the controller design, it is able to preserve the nominal control law unchanged and can operate properly without explicit information about system faults (fault diagnostic module). Simulation results, on a pendulum model, show the effectiveness of the proposed scheme for tracking control.
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies