Tytuł:
Hydrogel coatings for artificial heart implants
Autorzy:
Trzaskowski, M.
Butruk, B.
Ciach, T.
Tematy:
polyurethane
polyvinylpyrrolidone
hydrogel coatings
artificial heart
Pokaż więcej
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Powiązania:
https://bibliotekanauki.pl/articles/115623.pdf  Link otwiera się w nowym oknie
Opis:
Polyurethanes (PU) are nowadays one of the most widely used types of polymers for biomedical applications. The segmented nature of these materials enables to obtain both flexibility and mechanical strength within the same material. However, there is a need to modify a surface of PU in order to produce highly hemocompatible materials that can be used in fabrication of permanent blood-contacting devices such as vascular implants, valves or hearts. Among many types of modifications, hydrogel coating appears to be very promising. Such modification increases the hydrophilicity of PU which in turn causes an increase in the bio- and hemocompatibility of the material. The aim of presented study was to create a polyvinylpyrrolidone (PVP) hydrogel coating onto a surface of polyurethane. A possibility of using a free radical polymerization reaction was investigated. The obtained materials were analyzed in terms of durability, swelling ratio and contact angle. The FTIR-ATR analysis confirmed that polyurethane surfaces have been successfully coated with PVP.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cell outer membrane mimetic surface as a material with improved hemocompatibility
Autorzy:
Trzaskowski, M.
Butruk, B.
Ciach, T.
Tematy:
phosphatidylcholine
polyurethane
cell outer membrane mimetic surface
artificial heart
Pokaż więcej
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Powiązania:
https://bibliotekanauki.pl/articles/115627.pdf  Link otwiera się w nowym oknie
Opis:
The phenomenon of blood coagulation on the surfaces of implantable devices such as artifi cial blood vessels, valves or hearts is the major problem that has to be taken into consideration during the construction of such devices. Since the main factor that has an infl uence on clotting of blood is the surface of the material the device is made of, numerous attempts has already been undertaken to modify surfaces of existing materials in order to provide necessary protection against clot formation, very often by coating the materials with bio-active substances. The aim of presented study was to create a coating of phosphatidylcholine that would mimic natural cell outer membrane on the surface of polyurethane — a material already in use in construction of cardiovascular implants. The obtained coated materials have been evaluated with the use of FT-IR/ATR spectroscopy. The change in contact angle of modifi ed material was also investigated. Finally in vitro cytotoxicity tests were performed in order to examine biocompatibility of obtained material.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remote monitoring sytem for artificial heart
Autorzy:
Fajdek, B.
Stachura, M.
Syfert, M.
Wnuk, P.
Bartys, M.
Tematy:
remote monitoring system
telemetry
artificial heart
remote devices maintenance
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Powiązania:
https://bibliotekanauki.pl/articles/384347.pdf  Link otwiera się w nowym oknie
Opis:
This paper presents a general description of the platform for remote monitoring and supervision of heart assist devices (POLPDU). To facilitate a more in-depth understanding of this system and its development, firstly, a brief discussion on severe heart failure problem are given. Then, the short description of the core modules of the system is included. The main emphasis is placed on the communication between the heart assist devices and the central platform server. Finally, the directions of development of the system are discussed.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytm sterowania napędu mikropompy pulsacyjnej
The algorithm of the pulsatile micropump drive control system
Autorzy:
Bartel, S.
Tematy:
system sterowania
napęd elektromagnetyczny
mikropompa
sztuczne serce
control system
electromagnetic drive
micropump
artificial heart
Pokaż więcej
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Powiązania:
https://bibliotekanauki.pl/articles/408507.pdf  Link otwiera się w nowym oknie
Opis:
W niniejszym artykule przedstawiono projekt mikropompy pulsacyjnej napędzanej elektromagnetycznie będącej urządzeniem sztucznego serca typu TAH. Zaproponowano algorytm sterowania który umożliwia uzyskanie dowolnego kształtu ciśnień wylotowych i w tym charakterystyki ciśnień zbliżonych do naturalnego cyklu hemodynamicznego.
In this article is shown the construction and the algorithm of control system of the electromagnetically driven blood micropump. The discussed micropump is a device of an TAH device type. The blood flow pressure characteristic of the micropump drive can be modeled by using the proposed control algorithm, and the humans natural hemodynamic cycle can be generated.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kształtowanie sztucznej komory oraz napędu mikropompy pulsacyjnej do przetaczania krwi
Modeling of the artificial blood chamber and the micropumps pulsatile drive for blood transfusion
Autorzy:
Bartel, S.
Tematy:
sztuczna komora krwi
napęd elektromagnetyczny
mikropompa
sztuczne serce
artificial blood chamber
electromagnetic drive
micropump
artificial heart
Pokaż więcej
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Powiązania:
https://bibliotekanauki.pl/articles/408349.pdf  Link otwiera się w nowym oknie
Opis:
W niniejszym artykule zaprezentowano przykłady laminarnie przepływowych oraz pulsacyjnych urządzeń wspomagających pracę ludzkiego serca oraz całkowicie sztucznych serc. Przykłady tych urządzeń rozpatrywane były pod kątem modelowania kształtu sztucznych komór krwi oraz napędu elektromagnetycznego tych urządzeń. Opisano ogólną zasadę działania oraz wady i zalety wynikające z budowy danej konstrukcji.
This article presents examples of laminar blood flow and pulsatile blood flow devices for human heart assist and the total artificial hearts. The presented examples of these heart assist devices were considered for modeling the shape of the artificial blood chamber, and the electromagnetic drive of these devices. This article describes the general principle of artificial heart devices and his advantages and disadvantages resulting from the construction.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Drive optimisation of a pulsatile Total Artificial Heart
Autorzy:
Pohlmann, A.
Lessmann, M.
Finocchiaro, T.
Fritschi, A.
Steinseifer, U.
Schmitz-Rode, T.
Hameyer, K.
Tematy:
sztuczne serce
napęd liniowy
optymalizacja
straty
total artificial heart
TAH
linear drive
optimisation
losses
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/140887.pdf  Link otwiera się w nowym oknie
Opis:
Total Artificial Hearts (TAHs) are required for the therapy of terminal heart diseases as heart transplants are only a limited option due to the available number of donor hearts. For implantation TAHs have to meet constraints regarding its dimensions, weight, perfusions and electrical losses. An innovative linear driven TAH is presented, which meets all constraints except weight. Therefore the geometry of the linear drive is optimised to reduce its weights while simultaneously limiting the electrical losses as much as possible. In order to calculate the losses, this paper introduced a combined calculation chain consisting of FEM simulations and analytical equations. Based on this chain the linear drive is optmised by the method of parameter variations. The results yield a hierachic order of parameters which are most suitable for the weight reduction of the drive for low losses. By this the weight of the linear drive is reduced by 25%. As the allowable loss limit is not exceeded yet, room for further weight reduction achieved by an optimisation of the axial geomtry parameters is given.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nad degradacją chemiczną i mechaniczną kompozytu PEEK/włókno węglowe
Chemical and mechanical study of PEEK/carbon fibres composite
Autorzy:
Dworak, M.
Bloch, M.
Błażewicz, S.
Tematy:
kompozyty polimerowe
PEEK
właściwości mechaniczne
sztuczna zastawka serca
polymer composites
mechanical properties
artificial heart valve
Pokaż więcej
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Powiązania:
https://bibliotekanauki.pl/articles/285657.pdf  Link otwiera się w nowym oknie
Opis:
Praca przedstawia wstępne wyniki badań nad otrzymywaniem i określaniem właściwości mechanicznych nowego kompozytu typu PEEK/tkanina węglowa w warunkach statycznych i dynamicznych, w środowisku płynu Ringera. Materiał taki przewidywany jest do opracowania płatka sztucznej zastawki serca. Do otrzymywania kompozytu zastosowano tkaninę węglową 2-D jako wzmocnienie oraz polieteroteroketon (PEEK) jako osnowę. Otrzymany kompozyt poddano ocenie właściwości mechanicznych w warunkach statycznych przy pomocy maszyny wytrzymałościowej Zwick-1435 oraz badaniom zmęczeniowym na prototypowym urządzeniu laboratoryjnym do badania sztucznych zastawek serca w warunkach dynamicznego transportu płynu fizjologicznego.
The presented work demonstrates preliminary results of manufacture and mechanical properties assessment of the new composite PEEK/carbon fabrics, in static and dynamic conditions, as potential candidate for cardio surgery application. 2-D carbon fabrics as reinforcement constituent and semi-crystalline polymer-polyetheretherketone (PEEK) as a matrix were applied for the preparation of the composite. The obtained composite was investigated using Zwick machine - model 1435 and new laboratory device for artificial valve investigation in dynamic fluid transport conditions.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The notion of health in the opinion of the patients after implantation of artificial heart valves who are treated with the vitamin K antagonists (VKA)
Pojęcie zdrowia w opinii pacjentów po wszczepieniu sztucznych zastawek serca leczonych antagonistami witaminy K (VKA)
Autorzy:
Dzikowska, Mirosława
Pfitzner, Roman
Merklinger-Soma, Maria
Opis:
It is required for the patients who are after implantation of artificial heart valves to undertake different types of activities and their aim is to improve and maintain patients' health. The main aim is to define the term of health in the opinion of the patients after implanting artificial heart valves who are treated with VKA. The data from 155 patients after implanting artificial heart valves who are treated with VKA was scrutinised. The List of Health Criteria (LKZ) written by Juczyński was used. The patients highly prized the statement „it is the most important not to feel any physical ailments” and this statement referred to the criterion of health understood as the attribute.Ill people highly valued the criterion of health defined as the attribute which refers to the physical dimension of health and it may point out that the approach to this issue is instrumental.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Measurements of blood saturation inside a ventricular assist device
Autorzy:
Mocha, J.
Czerw, M.
Sobotnicki, A.
Tematy:
sztuczne serce
urządzenia wspomagające pracę komór
oksymetr tętna
artificial heart
ventricular assist device (VAD)
pulse oximeter
Pokaż więcej
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Powiązania:
https://bibliotekanauki.pl/articles/333266.pdf  Link otwiera się w nowym oknie
Opis:
Information about the level how well arterial blood is saturated with oxygen, i.e. the overall patient saturation, in particular a patient with a ventricular assist device (VAD) inoculated, is very important for efficient and dependable course of blood circulation support. The paper presents the method for measurement of blood saturation with oxygen that is carried out with use of a commercially available pulse oximetric sensor upon necessary modifications and installed directly on a outflow connector of the VAD. Operability of the presented solution has been verified by experiments on a flow control test bench with use of animal blood. The final validation of the measuring circuit was carried out during experiments with an animal. The completed experiments demonstrated that both the blood saturation with oxygen as well as artificial pulse rate can be measured with accuracy. Unfortunately, similar measurements for venous blood proved infeasible.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tomasz Cieszyński (1920-2010) – chirurg i wynalazca
Tomasz Cieszyński (1920-2010) – Surgeon and Inventor
Autorzy:
Mazurak, Magdalena
Tematy:
Tomasz Cieszyński, historia echokardiografii, echokardiografia
wewnątrzsercowa, sztuczne serce
Tomasz Cieszyński, history of echocardiography, intracardiac
echocardiography, artificial heart
Pokaż więcej
Wydawca:
Polskie Towarzystwo Historii Filozofii i Medycyny
Powiązania:
https://bibliotekanauki.pl/articles/2085442.pdf  Link otwiera się w nowym oknie
Opis:
W roku 2020 minęła setna rocznica urodzin profesora Tomasza Cieszyńskiego. W 1956 r. Tomasz Cieszyński (syn światowej sławy stomatologa Antoniego Cieszyńskiego) opatentował echosondę do badania struktur serca (echokardiografia wewnątrzsercowa). W pracy przedstawiono losy profesora Tomasza Cieszyńskiego oraz jego dokonania w medycynie, ze szczególnym uwzględnieniem kardiologii.
The year 2020 marked the 100th anniversary of the birth of Tomasz Cieszyński. In 1956, Tomasz Cieszyński (the son of a world renowned dentist, Professor Antoni Cieszyński) patented an original idea of using a device allowing for an assessment of heart structures, i.e. an echosounder placed inside the heart (intracardiac echocardiography). The paper presents the history of life of Professor Tomasz Cieszyński as well as his achievements in the fields of medicine, especially in cardiology.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies