Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "asynchronous machine" wg kryterium: Temat


Tytuł:
Detection of faults in the asynchronous machine by the use of smartmaterials
Autorzy:
Regaz, A.
Zegnini, B.
Mahi, D.
Boukezzi, L.
Tematy:
piezoelectric
magnetostrictive
diagnosis
asynchronous machine
piezoelektryk
maszyna asynchroniczna
magnetostrykcja
diagnostyka
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Powiązania:
https://bibliotekanauki.pl/articles/329694.pdf  Link otwiera się w nowym oknie
Opis:
This paper aimed with diagnosis of defects in asynchronous machine. The used method is based on the exploitation of the behavioural laws of magnetostrictive and piezoelectric materials, under harmonic regime, used in the construction of the asynchronous machine. Piezoelectric sensors are used both in the stator and in the rotor. The used one in the stator serves to detect the rupture at the stator windings and the one used in the rotor helps us to detect the rupture of the rotor bars. The produced electric potential in the terminals of piezoelectric sensor is due to the deformation generated by magnetic induction under the effect of magnetostriction. A finite element method (FEM) is selected to be the resolution numerical method. This method is used for modelling the asynchronous machine under anomaly conditions and non-load.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of numerically determined noise of a 290 kW induction motor using FEM and measured acoustic radiation
Autorzy:
Nahlaoui, M. Al
Steins, H.
Kulig, S.
Exnowski, S.
Tematy:
inverter-fed
induction motor
asynchronous machine
acoustic radiation
modal analysis
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/140646.pdf  Link otwiera się w nowym oknie
Opis:
In this paper a comparison of numerically determined and measured electromagnetically exited noise of an induction motor is presented. The calculations are accomplished using FEM for an example motor, which is a 290 kW inverter-fed asynchronous machine. The approach starts with the electromagnetic and mechanical consideration. The focus is set on acoustic considerations, which contain the 3D-FE-model and measurement setup in the sound chamber.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural Model of the Electric Drive with Double-Fed Asynchronous Machine and Direct Torque Control
Autorzy:
German-Galking, S.
Kozak, M.
Tematy:
control flux and torque
double-fed asynchronous machine
package Matlab–Simulink
Pokaż więcej
Wydawca:
STE GROUP
Powiązania:
https://bibliotekanauki.pl/articles/2064935.pdf  Link otwiera się w nowym oknie
Opis:
At present, the development of modern complex objects management systems, including electric motors, must include the step of modelling studies, which allows you to obtain basic characteristics, slightly different from the real characteristics of the object. The development of an adequate model, which can simulate the system under investigation, eliminates the stage of conceptual design and significantly reduce the engineering design stage, and therefore saves time and money.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency improvement due to direct torque and flux three levels three areas control method applied to small hydroelectric power plant
Autorzy:
Kulikowski, K.
Sikorski, A.
Tematy:
asynchronous machine
AC/DC/AC converter
DC/AC converter
DTC
flux control
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/200033.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents a description of a new DTFC3L3A (direct torque and flux control three levels three areas) control method of induction machine as well as its comparison with the DTC method. The basis for the comparison is the switching frequency of described methods. The proposed method is optimized to reduce number of switchings (which is proportional to switching power losses) in static state, as well as it takes into account the angle which makes it possible to obtain a sinusoidal shape of flux within range of low angular frequencies of an asynchronous machine. The paper includes the results of experiments performed on a three level DC/AC inverter for both control methods.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault diagnosis of induction motors rotor using current signature with different signal processing techniques
Autorzy:
Guezam, Abdelhak
Bessedik, Sid Ahmed
Djekidel, Rabah
Tematy:
asynchronous machine
rotor defect
diagnostic
signal processing
FFT
HT
WT
maszyna asynchroniczna
diagnostyka
przetwarzanie sygnałów
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Powiązania:
https://bibliotekanauki.pl/articles/2096189.pdf  Link otwiera się w nowym oknie
Opis:
The popularity of asynchronous machines, particularly squirrel cage machines, stems from their inexpensive production costs, resilience, and low maintenance requirements. Unfortunately, potential flaws in these devices might have a negative impact on the facility's profitability and service quality. As a result, diagnostic tools for detecting flaws in these types of devices must be developed. Asynchronous machine problems can be diagnosed using a variety of methods. Signal processing techniques based on extracting information from characteristic quantities of electrical machine operation can provide highly useful information about flaws. The purpose of this research is to develop efficient algorithms based on numerous signal processing approaches for correctly detecting asynchronous cage machine rotor defects (rotor bar ruptures).
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of numerically determined noise of a 290 kW induction motor using fem and measured acoustic radiation
Autorzy:
Al Nahlaoui, M.
Steins, H.
Kulig, S.
Exnowski, S.
Tematy:
inverter-fed
induction motor
asynchronous machine
acoustic radiation
FEM
noise
surface vibration
modal analysis
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/1813585.pdf  Link otwiera się w nowym oknie
Opis:
Abstract - In this paper a comparison of numerically determined and measured electromagnetically exited noise of an induction motor is presented. The calculations are accomplished using FEM for an example motor, which is a 290 kW inverter-fed asynchronous machine. The approach starts with the electromagnetic and mechanical consideration. The focus is set on acoustic considerations, which contain the 3D-FE-model and measurement setup in the sound chamber. The determination of the induction and force waves is presented using parts of the results. In the case of the mechanical modeling the three dimensional FE-model is shown.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern Direct Torque and Flux Control methods of an induction machine supplied by three-level inverter
Autorzy:
Sikorski, A.
Kulikowski, K.
Korzeniewski, M.
Tematy:
asynchronous machine
DC/AC inverter
DTC
flux and torque control
3-level DC/AC inverter
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/201199.pdf  Link otwiera się w nowym oknie
Opis:
This paper describes two modern direct torque and flux control methods of an induction machine supplied by a three-level inverter. Additionally, it presents a comparison of the methods both in static and dynamic states. The methods, in a specific way, make use of an increased number of active vectors of the three-level inverter in order to improve control quality and reduce switching frequency. The two methods modify the DTC method by using its advantages and eliminating, at the same time its drawbacks. In static states the comparison was based on the results of investigations performed for two different load values and three set values of angular speed, whereas in dynamic states the comparison was focused on the behavior of the machine at startup. The results of the investigations have shown that both methods give very good performance. They are characterized by both sinusoidal shape of flux and low current deformations even at low angular speeds i.e. less than 10% of the nominal value. The presented methods also allow to generate nominal flux for set zero angular speed in order to achieve excitation of the induction machine. The switching frequencies for both methods are very similar in almost the whole range of control but the methods have shown some differences in control quality, particularly for higher torque values.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania mocy w modelu elektrowni wiatrowej z generatorem asynchronicznym dwustronnie zasilanym
Investigations of power in a wind plant model with double fed asynchronous generator
Autorzy:
Łapiński, P.
Kuźma, A.
Tematy:
maszyna asynchroniczna dwustronnie zasilana
elektrownia wiatrowa
odnawialne źródła energii
double fed asynchronous machine
wind power plant
energy sources
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Powiązania:
https://bibliotekanauki.pl/articles/1196929.pdf  Link otwiera się w nowym oknie
Opis:
The work presents a laboratory stand designed to study the wind farm model with a double fed asynchronous generator located in the Electrical Department of the Bialystok University of Technology. Properly connected station modules give the user the possibility to perform tests in various configurations and cases that may occur during the normal use of a real wind farm and in emergency conditions of the power supply network. The article presents the results of research showing the power generator asynchronous double fed during normal operation and during the occurrence of voltage dips in the power grid.
W pracy zaprezentowane zostało stanowisko laboratoryjne, znajdujące się w Wydziale Elektrycznym Politechniki Białostockiej, przeznaczone do badania modelu elektrowni wiatrowej z maszyną indukcyjną dwustronnie zasilaną. Odpowiednio połączone moduły stanowiska dają użytkownikowi możliwość wykonywania badań w różnych konfiguracjach i przypadkach mogących wystąpić podczas normalnego użytkowania rzeczywistej elektrowni wiatrowej oraz w stanach awaryjnych sieci zasilającej. W artykule przedstawione zostaną wyniki badań ukazujące moc generatora asynchronicznego dwustronnie zasilanego w stanach normalnej pracy oraz podczas występowania zapadów napięcia w sieci zasilającej.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania elektrowni wiatrowej z silnikiem asynchronicznym dwustronnie zasilanym w stanach awaryjnych
Investigations of wind plant with double fed asynchronous generator
Autorzy:
Łapiński, P.
Kuźma, A.
Tematy:
maszyna asynchroniczna dwustronnie zasilana
elektrownia wiatrowa
odnawialne źródła energii
double fed asynchronous machine
wind power plant
renewable energy sources
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Powiązania:
https://bibliotekanauki.pl/articles/1199659.pdf  Link otwiera się w nowym oknie
Opis:
A laboratory model introduced for the wind plant with double fed asynchronous generator investigations is proposed in article. An user thanks to adequate modules connections may investigate different systems configurations and operation modes which can happened in practice. Operation principle of double fed asynchronous generator driven by wind, its synchronization with grid, energy flows to the grid will be presented in short. The investigations results showing: influence of the rotor parameters on the stator, the power control above and below the synchronous velocity, operations during a gust of wind will be presented.
W pracy zaprezentowane zostanie stanowisko laboratoryjne przeznaczone do badania elektrowni wiatrowej z maszyną indukcyjną dwustronnie zasilaną w stanach awaryjnych sieci zasilającej. Odpowiednio połączone moduły stanowiska dają użytkownikowi możliwość wykonywania badań symulujących zachowania rzeczywistej elektrowni wiatrowej podczas zakłóceń w sieci zasilającej. W skrócie opisany zostanie moduł symulujący zapady napięcia i zwarcia w sieci zasilającej. Przedstawione zostaną wyniki badań ukazujące reakcję części mechanicznej turbiny wiatrowej przy 100% zapadach napięcia oraz utrzymanie pracy turbiny przy różnych rodzajach zwarć.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ sterowania i monitorowania pracy przekształtnikowego napędu maszyny wyciągowej z silnikiem asynchronicznym
Control and monitoring system of the operation of converter drive of winding machine with asynchronous motor
Autorzy:
Kozłowski, A.
Gąsior, T.
Zdrzałek, J.
Tematy:
maszyna wyciągowa
napęd maszyn wyciągowych
silnik asynchroniczny
sterowanie
monitorowanie
winding machine
drive of winding machine
asynchronous motor
control
monitoring
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Powiązania:
https://bibliotekanauki.pl/articles/187575.pdf  Link otwiera się w nowym oknie
Opis:
W artykule przedstawiono przekształtnikowe układy sterowania napędów, opracowane w Instytucie EMAG, ich podstawowe parametry oraz możliwości zastosowań w instalacjach przemysłowych. Zaprezentowano zalety, a także możliwości sterowania mikroprocesorowego tych napędów w zastosowaniu do maszyn wyciągowych i przepływowych. Omówiono sposób rozwiązania problemów związanych z koniecznością precyzyjnej regulacji momentu przy bardzo małych prędkościach obrotowych przez zastosowanie regulatora adaptacyjnego oraz problemy hamowania dynamicznego przy prędkościach maksymalnych. W krótkim podsumowaniu przedstawiono zalety zastosowania napędu przekształtnikowego zarówno w aspekcie oszczędności energii, jak i uzyskiwanych parametrów pracy maszyny czy zmniejszenia oddziaływania na sieć zasilającą.
In this article converter control systems of drives are presented, developed in the EMAG Institute, as well as their basic technical specifications and applicability in industrial installations. The control system of the converter drive has been described and the advantages and possibilities of these drives being microprocessor controlled have been presented, when applied to winding machines, as well as to fluid-flow machine drives. The solution for the issue of constructing the system and specific aspects of its application to control the driving system of winding machine have been described. The way of solving problems regarding the necessity of regulating the moment with precision when the rotational speed is very low, using the adaptive control, has been discussed, as well as issue of dynamic braking with maximum speeds. In a brief summary the advantages of the application of converter drive have been presented, regarding both energy saving and obtained parameters of machine operation or reducing the effect on power supply network.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies