Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "biomechanical properties" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Biomechanical properties of the thin PVD coatings defined by red blood cells
Autorzy:
Bruckert, F.
Lackner, J.M.
Jasek-Gajda, Ewa
Major, B.
Major, R.
Trembecka-Wojciga, K.
Opis:
The measurement of the strength of bonds between biomaterials and cells is a major challenge in biotribology since it allows for the identification of different species in adhesion phenomena. Biomaterials, such as diamond-like carbon (DLC), titanium, and titanium nitride, seem to be good candidates for future blood-contact applications. These materials were deposited as thin films by the hybrid pulsed laser deposition (PLD) technique to examine the influence of such surfaces on cell behavior. The biomaterial examinations were performed in static conditions with red blood cells and then subjected to a dynamical test to observe the cell detachment kinetics. The tests revealed differences in behavior with respect to the applied coating material. The strongest cell-biomaterial interaction was observed for the carbonbased materials compared to the titanium and titanium nitride. Among many tests, a radial flow interaction analysis gives the opportunity to analyze cell adhesion to the applied material with the high accuracy. Analysis of concentrates helped to select materials for further dynamic tests on blood using an aortic flow simulator. In this case, the platelet adhesion to the surface and their degree of activation was analyzed. The quality of the selected coating was tested using a scratch test. The analyses of the microstructure were done using high resolution transmission electron microscopy. The phase composition and the residual stress were analyzed using X-ray diffraction methods.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Poziom rozwijanego statycznego momentu siły a wysokość skoku CMJ studentów AWF we Wrocławiu
The level of the static moment of force and cmj height of university school of physical education students
Autorzy:
Struzik, A.
Pietraszewski, B.
Tematy:
moment siły
staw kolanowy
własności biomechaniczne
moment of force
knee joint
biomechanical properties
Pokaż więcej
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Powiązania:
https://bibliotekanauki.pl/articles/99255.pdf  Link otwiera się w nowym oknie
Opis:
W pracy poszukiwano związku między statycznym momentem siły prostowników i zginaczy stawu kolanowego (sumy prostowników i sumy zginaczy) a wysokością skoku CMJ. Rejestracji sił reakcji podłoża dokonano używając platformy dynamometrycznej firmy Kistler i oprogramowania BioWare. Badania przeprowadzono na grupie 30 studentów IV roku AWF we Wrocławiu w Pracowni Analiz Biomechanicznych. Badanymi były osoby uprawiające sport wyczynowo od minimum 5 lat. Badania miały na celu ocenę własności biomechanicznych (mierzonych w działaniach statycznych i dynamicznych) kończyn dolnych człowieka.
The purpose of the research was to determine the relationship between the static moment of force of knee joint flexors and extensors (sum of flexors and sum of extensors) and the height of CMJ jump. Dynamometric Kistler plate and BioWare software were applied to record the ground reaction force. 30 University School of Physical Education students participated in the study. The research was conducted in the Laboratory of Biomechanical Analysis in Wroclaw. Subjects have been performing professional sport no less than 5 years. The purpose of the research was to assess the biomechanical properties of the lower limbs (measured during static and dynamic exercises).
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of strength properties of the temporomandibular joint disc
Autorzy:
Szust, Agnieszka
Wybraniec, Anna
Wielgus, Gabriela
Tematy:
temporomandibular joint disc
biomechanical properties
dimensionless energy dissipation factor
susceptibility
biomateriały
właściwości biomechaniczne
Pokaż więcej
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Powiązania:
https://bibliotekanauki.pl/articles/58809861.pdf  Link otwiera się w nowym oknie
Opis:
The purpose of this research was to determine selected biomechanical properties of the temporomandibular disc. After endurance tests and once the load-displacement characteristics were determined, the susceptibility and dimensionless energy dissipation coefficient were determined. The research was carried out on ten discs (six fresh and four frozen) taken from five young pigs. Endurance tests were conducted in the laboratory of Wrocław University of Science and Technology, using the INSTRON 5944 machine. All tested discs were kept in a NaCl solution heated to 37.5ºC during the experiment. A recurring difference of 1 mm in the height of the fresh and frozen discs was observed. In contrast, the strength of the discs was similar regardless of the method of storing the preparation. The material susceptibility values ranged from 0.4 to 1.4 millimetre per Newton, and the dimensionless energy dissipation factor oscillated between 0.27 and 0.87. The aim of these experimental investigations was to determine the compressive force at predefined strain levels and to elucidate the loading characteristics corresponding to displacement. Due to the observed variability in these characteristics across consecutive measurement cycles, the analysis in this paper is restricted to the results obtained from the first measurement series.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical properties of the thin PVD coatings defined by red blood cells
Autorzy:
Trembecka-Wojciga, K.
Major, R.
Lackner, J. M.
Bruckert, F.
Jasek, E.
Major, B.
Tematy:
biomechanical properties
thin PVD coatings
red blood cells
właściwości biomechaniczne
cienkie powłoki PVD
krwinki czerwone
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/201364.pdf  Link otwiera się w nowym oknie
Opis:
The measurement of the strength of bonds between biomaterials and cells is a major challenge in biotribology since it allows for the identification of different species in adhesion phenomena. Biomaterials, such as diamond-like carbon (DLC), titanium, and titanium nitride, seem to be good candidates for future blood-contact applications. These materials were deposited as thin films by the hybrid pulsed laser deposition (PLD) technique to examine the influence of such surfaces on cell behavior. The biomaterial examinations were performed in static conditions with red blood cells and then subjected to a dynamical test to observe the cell detachment kinetics. The tests revealed differences in behavior with respect to the applied coating material. The strongest cell-biomaterial interaction was observed for the carbon-based materials compared to the titanium and titanium nitride. Among many tests, a radial flow interaction analysis gives the opportunity to analyze cell adhesion to the applied material with the high accuracy. Analysis of concentrates helped to select materials for further dynamic tests on blood using an aortic flow simulator. In this case, the platelet adhesion to the surface and their degree of activation was analyzed. The quality of the selected coating was tested using a scratch test. The analyses of the microstructure were done using high resolution transmission electron microscopy. The phase composition and the residual stress were analyzed using X-ray diffraction methods.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of extracellular vesicles excreted by melanoma cells on biomechanical properties of cells that build up the blood vessel wall
Wpływ zewnątrzkomórkowych pęcherzyków wydzielanych przez komórki czerniaka na właściwości biomechaniczne komórek budujących ścianę naczynia krwionośnego
Autorzy:
Koszut, Aleksandra
Opis:
Growing number of studies indicates the importance of extracellular vesicles excreted by cells in different biological processes, including metastasis of cancer cells. In the present study, the impact of extracellular vesicles excreted by melanoma cells on the biomechanical properties of cells that build up the blood vessel wall was examined.The main research material of the study was extracellular vesicles obtained from culture media of melanoma cells and primary culture of αSMA-positive cells isolated from the chorioallantoic membrane of a chicken embryo. The size of the vesicles was measured using dynamic light scattering, whereas morphology was analyzed with atomic force microscopy. Next, both morphology and elasticity of αSMA-positive cells treated with the vesicles were examined using atomic force microscopy and spectroscopy techniques. Organization of cell cytoskeleton was assessed with scanning laser confocal microscope. Based on the obtained results, relationships between the values of the Young’s modulus and thickness of stress fibers of control cells and of cells treated with the vesicles were determined.This study indicates that extracellular vesicles excreted by melanoma cells can lead to modifications of the biomechanical properties of cells that build up the blood vessel wall, facilitating invasion of melanoma cells.
Coraz więcej prowadzonych badań wskazuje na istotne znaczenie pęcherzyków zewnątrzkomórkowych wydzielanych przez komórki w różnych procesach biologicznych w tym również w procesie przerzutowania komórek nowotworowych. W niniejszej pracy zbadano wpływ pęcherzyków zewnątrzkomórkowych wydzielanych przez komórki czerniaka na właściwości biomechaniczne komórek budujących ścianę naczynia krwionośnego. Głównym materiałem badawczym, wykorzystanym w pracy były pęcherzyki zewnątrzkomórkowe uzyskane z płynu hodowlanego komórek czerniaka oraz pierwotna hodowla komórek αSMA-pozytywnych wyizolowana z błony kosmówkowo-owodniowej zarodka kurzego. Wykonano analizę rozmiaru pęcherzyków, wykorzystując zjawisko dynamicznego rozpraszania światła oraz ich morfologii za pomocą mikroskopu sił atomowych. Następnie zbadano morfologię oraz sprężystość komórek αSMA-pozytywnych traktowanych pęcherzykami, przy użyciu mikroskopii spektroskopii sił atomowych. Zbadano również organizację cytoszkieletu komórek, wykorzystując skaningowy laserowy mikroskop konfokalny. Na podstawie otrzymanych wyników wyznaczono zależności pomiędzy wartościami modułów Younga a grubością włókien naprężeniowych komórek kontrolnych i traktowanych pęcherzykami. Wykazano, że pęcherzyki zewnątrzkomórkowe wydzielane przez komórki czerniaka mogą prowadzić do zmiany właściwości biomechanicznych komórek budujących ścianę naczynia krwionośnego, umożliwiając tym samym ułatwioną inwazję komórek czerniaka przez naczynia krwionośne.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Inne
Tytuł:
An analysis of the effect of impact loading on the destruction of vascular structures in the brain
Autorzy:
Ratajczyk, M.
Sąsiadek, M.
Będziński, R.
Tematy:
mózg
system naczyyniowo-mózgowy
właściwości mechaniczne
FEM
model dynamiczny
bridging vein rupture
subdural haematoma
biomechanical properties
cerebrovascular system
impact loading
dynamic model
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/307119.pdf  Link otwiera się w nowym oknie
Opis:
Subdural hematomas are one of the frequent complications of head injuries. Such hematomas result from exceeding the border strength values of bridging veins. Subdural haemorrhages are life-threatening and are a frequent cause of considerable pathologies. Traffic participants and also soldiers who participate in armed conflicts are the most vulnerable to head injuries. Although hematomas have been studied for many years the mechanism of hematoma formation has not been fully clarified as yet. In the paper, the effort of brain tissue structures due to the propagation of shock wave was analyzed. Particular attention was paid to the deformation ability and changes in the energy of bridging veins. This research was concerned with changes in mechanical properties of these veins in the frontal, parietal and occipital regions of the brain. For the present research the authors have constructed finite element models of brain tissue fragments and conducted numerical studies taking into account the boundary conditions arising from violent overloads that result from combat operations. As a result of the numerical analysis conducted, critical values of strain and stress have been obtained. The analysis showed high diversity in the properties of the different regions of the brain tissue. The studies carried out by the authors rendered it possible to assess the effort of the tissue structures of veins in connection with mechanical parameters, including geometrical parameters, in particular in relation to the likelihood of hematoma formation.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uwagi o wyznaczaniu danych somatycznych człowieka dla zadań symulacji dynamicznej
Remarks on assessment of human body properties for inverse dynamics simulation
Autorzy:
Mazur, Z.
Dziewiecki, K.
Blajer, W.
Tematy:
układ biomechaniczny
ruch człowieka
symulacja dynamiczna odwrotna
siły mięśniowe
dane somatyczne
biomechanical system
human motion
inverse dynamics simulation
muscular force
human body properties
Pokaż więcej
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Powiązania:
https://bibliotekanauki.pl/articles/99108.pdf  Link otwiera się w nowym oknie
Opis:
Jakość uzyskiwanych wyników symulacji dynamicznej odwrotnej układów biomechanicznych jest wypadkową wielu czynników: adekwatności modelu matematycznego, poprawności algorytmu obliczeniowego, techniki pozyskiwania danych kinematycznych oraz precyzyjnej identyfikacji parametrów masowo-geometrycznych modelu. Niniejsza praca dotyczy tego ostatniego czynnika. Pokazane są różnice przy wyznaczaniu danych somatycznych zależnie od zastosowanej metody oraz formułowane wnioski o charakterze praktycznym.
Quality of results from inverse dynamics simulation of biomechanical systems depends on many factors: adequacy of the mathematical model used, correctness of the computational schemes, precision of recorded kinematic data, and exactness of identified inertial and geometric parameters of the modeled body. The present paper is focused on the latter issue. Differences in the inertial and geometric parameters are shown when using various methods and sources from the literature, which vividly influence the (reported) results obtained from the inverse dynamics simulation.
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies