Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "central heating" wg kryterium: Temat


Tytuł:
The architecture for testing central heating control algorithms with feedback from wireless temperature sensors
Autorzy:
Markiewicz, Michał
Skała, Aleksander
Grela, Jakub
Janusz, Szymon
Stasiak, Tadeusz
Bańczyk, Katarzyna
Bielecki, Andrzej
Latoń, Dominik
Opis:
The energy consumption of buildings is a significant contributor to overall energy con- sumption in developed countries. Therefore, there is great demand for intelligent buildings in which energy consumption is optimized. Online control is a crucial aspect of such optimization. The imple- mentation of modern algorithms that take advantage of developments in information technology, artificial intelligence, machine learning, sensors, and the Internet of Things (IoT) is used in this context. In this paper, an architecture for testing central heating control algorithms as well as the control algorithms of the heating system of the building is presented. In particular, evaluation metrics, the method for seamless integration, and the mechanism for real-time performance monitoring and control are put forward. The proposed tools have been successfully tested in a residential building, and the conducted tests confirmed the efficiency of the proposed solution.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
System centralnego ogrzewania i jego wpływ na zużycie ciepła do ogrzewania budynków
Central heating system and his influence on heat consumption for heating
Autorzy:
Lis, P.
Lis, A.
Tematy:
system centralnego ogrzewania
budynki edukacyjne
central heating systems
educational buildings
Pokaż więcej
Wydawca:
Politechnika Częstochowska
Powiązania:
https://bibliotekanauki.pl/articles/2065073.pdf  Link otwiera się w nowym oknie
Opis:
W artykule wykorzystano wyniki badań własnych prowadzonych w budynkach edukacyjnych. Dla scharakteryzowania systemów centralnego ogrzewania w badanych budynkach poddano analizie kilka cech zasadniczych dla systemu ogrzewania. Zaliczono do nich: rodzaj źródła zasilania w ciepło instalacji centralnego ogrzewania, eksploatację instalacji, wyposażenie systemu centralnego ogrzewania w urządzenia i automatykę regulacyjną, charakterystykę źródła ciepła w kotłowniach własnych oraz eksploatację indywidualnego źródła ciepła.
This paper describes central heating systems in the studied educational buildings. The analysis considers a few basic features of a heating system. They include: the type of power source, exploitation and equipment of central heating system and characteristics of the heat source.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experiences from operation of different expansion devices for application in domestic micro CHP
Autorzy:
Mikielewicz, D.
Mikielewicz, J.
Wajs, J.
Tematy:
micro CHP
ogrzewanie centralne
rozbudowa urządzeń
central heating
expansion devices
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/240544.pdf  Link otwiera się w nowym oknie
Opis:
In the paper presented are experiences from operation of three different expansion devices for possible implementation in the domestic micro CHP. These were the modified scroll expander and two designs based on the variable working chamber volume pneumatic devices. Experiments showed the superiority of both "pneumatic devices" over the scroll expander, indicating the possible internal efficiencies in the range of 61 82Such efficiencies are very attractive, especially at the higher end of that range. The volume of these devices is much smaller than the scroll expander which makes it again more suitable for a domestic micro CHP. Small rotational velocities enable to conclude that connection to electricity grid will also be simpler in the case of "pneumatic devices". The "pneumatic devices" under scrutiny here could be an alternative to the typical vapour turbine in the ORC cycle, which is in the process of development at the IFFM.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementation of building a thermal model to improve energy efficiency of the central heating system - a case study
Autorzy:
Grela, Jakub
Markiewicz, Michał
Skała, Aleksander
Latoń, Dominik
Ożadowicz, Andrzej
Bańczyk, Katarzyna
Opis:
This paper presents the concept of an innovative control of a central heating system in a multifamily building based on the original thermodynamic model, the resulting architecture of the control system, and the originally designed and manufactured wireless temperature sensors for thermal zones. The novelty of this solution is the developed layers of the control system: distributed measurement and correction analysis, which is based on the existing infrastructure and the local HVAC controller. This approach allows for the effective use of the measured temperature data from thermal zones and finally sending the value of the calculated correction of settings to the controller. Moreover, in the analytical layer, a model was also implemented that calculates the necessary amount of energy based on data from the subsystem of temperature sensors located in the thermal zones of the building. The use of the algorithmic strategy presented in this paper extends the functionality and significantly improves the energy efficiency of the existing, classic, reference heating control algorithm by implementing additional control loops. Additionally, it enables integration with demand-side response systems. The presented concept was successfully tested, achieving real energy savings for heating by 12%. These results are described in a case-study format. The authors believe that this concept can be used in other buildings and thus will have a positive impact on the energy savings used to maintain thermal comfort in buildings and significantly reduce CO2 emissions.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Ocena prawidłowości rozliczania kosztów ogrzewania w budynkach wielorodzinnych na podstawie wskazań podzielników ciepła
Evaluation of the correctness of heating costs in multi-family buildings based on heat cost allocators
Autorzy:
Kysiak, A.
Ujma, A.
Tematy:
podzielniki kosztów ogrzewania
koszt ogrzewania
ogrzewanie
heat cost allocators
heating costs
heating of buildings
central heating
Pokaż więcej
Wydawca:
Politechnika Częstochowska
Powiązania:
https://bibliotekanauki.pl/articles/2065519.pdf  Link otwiera się w nowym oknie
Opis:
Artykuł omawia problem niedostosowania metody rozliczania kosztów ogrzewania lokali w budynkach wielorodzinnych z zastosowaniem indywidualnych podzielników ciepła do faktycznych warunków eksploatacji mieszkań. Autorzy przedstawili w nim własne ustalenia wynikające z analizy danych dotyczących zużycia ciepła i kosztów c.o. w budynkach wielorodzinnych osiedla mieszkaniowego oraz przeprowadzonych oględzin lokali mieszkalnych. Na tej podstawie sformułowano wnioski dotyczące przyczyn zawyżania kosztów ogrzewania lokali mieszkalnych ustalanych na podstawie odczytów wskazań podzielników ciepła.
The article discusses the problem of non-adjustment of the method of settling the costs of heating premises in multi-family buildings with the use of individual heat cost allocators to the actual conditions of housing operation. The authors presented their own findings resulting from the analysis of data on heat consumption and c.o. in multi-family buildings of a housing estate and completed inspections of residential premises. On this basis, conclusions were formulated regarding the reasons for overheating of residential premises determined based on the readings of heat cost allocators.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Paliwa opałowe przyszłości – badania kotła centralnego ogrzewania zasilanego alkoholem etylowym
Heating fuels of the future - tests of a central heating boiler fed by ethyl alcohol
Autorzy:
Basiura, Maciej
Rataj, Mateusz
Tematy:
paliwa opałowe
alkohol etylowy
kocioł centralnego ogrzewania
heating fuel
ethyl alcohol
central heating boiler
Pokaż więcej
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Powiązania:
https://bibliotekanauki.pl/articles/31344058.pdf  Link otwiera się w nowym oknie
Opis:
W pierwszej części opisano prace badawcze podejmowane w Instytucie Nafty i Gazu – Państwowym Instytucie Badawczym w związku ze stopniowym odchodzeniem rozwiniętych gospodarek światowych od paliw kopalnych. Przedstawiono prace dotyczące zagospodarowania biogazu rolniczego oraz jego mieszanek z wysokometanowym gazem ziemnym i LPG na potrzeby zasilania urządzeń gazowych do użytku domowego oraz przemysłowych urządzeń gazowych. Opisano również trwające badania nad wykorzystaniem wodoru jako medium umożliwiającego zagospodarowanie i magazynowanie nadwyżek energii elektrycznej z odnawialnych źródeł energii (ang. power to gas, P2G). Prace te skupiają się na bezpieczeństwie użytkowania mieszanin wodoru z wysokometanowym gazem ziemnym, a także na wpływie domieszek wodoru na wszystkie elementy systemu przesyłowego. Przedstawiono także prace dla sektora transportu opisujące wykorzystanie bioetanolu jako dodatku do benzyn lub oleju napędowego. Pozwala to na zmniejszenie zużycia stosowanych paliw konwencjonalnych również w transporcie. Zaprezentowano też analizy, na podstawie których stwierdzono możliwość wykorzystania alkoholu etylowego jako paliwa opałowego do urządzeń grzewczych. W celu potwierdzenia wyników tych analiz przeprowadzono badania kotła centralnego ogrzewania wyposażonego w olejowy palnik nadmuchowy. Kocioł c.o. przebadano w cyklu badawczym, podczas którego temperatura wody zasilającej instalację c.o. wynosi 80°C, a temperatura wody wracającej do kotła – 60°C. W takich warunkach pracy urządzenia zmierzono parametry energetyczne kotła, tj. sprawność i obciążenie cieplne, oraz zmierzono ilość produkowanego kondensatu. Badania przeprowadzono, używając do zasilania kotła lekkiego oleju opałowego oraz alkoholu etylowego technicznego 96-procentowego. Na tej podstawie wyciągnięto następujące wnioski: obciążenie cieplne osiągane przez układ grzewczy uległo zmniejszeniu pomimo regulacji dostępnych parametrów urządzenia (ciśnienie na palniku oraz ilość powietrza do spalania); sprawność urządzenia nie uległa pogorszeniu; zawartość substancji niepożądanych w spalinach uległa obniżeniu; ilość produkowanego kondensatu w palniku zasilanym alkoholem etylowym uległa zwiększeniu względem tego samego palnika pracującego na oleju opałowym. W końcowej części usystematyzowano i przedstawiono wnioski z przeprowadzonych badań.
The first part describes the research work undertaken at the Oil and Gas Institute – National Research Institute in connection with the gradual transition of the developed world economies away from fossil fuels. Works on the management of agricultural biogas and its mixtures with high-methane natural gas and LPG for the purposes of supplying domestic and industrial gas appliances were presented. Works on the use of hydrogen as a medium enabling the management and storage of electricity surplus from renewable energy sources (P2G – Power to Gas) were also presented. These works focus on the safe use of mixtures of hydrogen with high-methane natural gas, as well as the influence of hydrogen admixtures on all elements of the transmission system. Another works presented are those related to the transport sector, describing the use of bioethanol as an additive to petrol or diesel. This allows to reduce the consumption of conventional fuels used also in transport. Analyses based on which the feasibility of using ethanol as heating fuel for heating appliances were also presented. In order to confirm the results of these analyses, tests were carried out on a central heating boiler equipped with an oil-fired burner. Central heating boiler was tested in the test cycle during which the temperature of water supplying the central heating installation was 80°C and the temperature of water returning to the boiler – 60°C. Under such operating conditions, the boiler's energy parameters, i.e. efficiency and thermal load, as well as the amount of produced condensate were measured. The tests were carried out using light fuel oil and 96% technical ethyl alcohol to power the boiler. Based on this, the following conclusions were drawn: the thermal load achieved by the heating system has decreased, despite the adjustment of the available parameters of the device (pressure on the burner and the amount of air for combustion); the efficiency of the device does not deteriorate; the content of undesirable substances in the exhaust gas has decreased; the amount of produced condensate in the ethanol-fired burner increases compared to the same burner running on oil. In the final part, the conclusions of the research were systematized and presented.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Węgiel w energetyce zawodowej i ciepłownictwie – stan obecny i perspektywy
Coal in energy generation and direct heating – current status and prospects
Autorzy:
Kielerz, Anna
Porzerzyńska-Antonik, Monika
Tematy:
węgiel
energetyka zawodowa
ciepłownictwo
miks energetyczny
coal
electricity generation
central heating
energy mix
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Powiązania:
https://bibliotekanauki.pl/articles/394816.pdf  Link otwiera się w nowym oknie
Opis:
Postępujące procesy globalizacyjne, zmiany w strukturze gospodarki światowej, europejskiej i lokalnej wymagają zintegrowanych działań służących rozwiązywaniu problemów związanych z rozwojem państw, regionów i miast – a dotyczących m.in.: środowiska, źródeł energii, klimatu, transformacji technologicznej. Każdy kraj Unii Europejskiej ma prawo tworzenia własnego miksu energetycznego. Polska posiada zasoby węgla kamiennego, które mogą zapewnić bezpieczeństwo energetyczne kraju na kilka dziesięcioleci. Można z całą odpowiedzialnością stwierdzić, że mimo wzrastającego udziału ropy naftowej i gazu w zużyciu paliw, węgiel (kamienny i brunatny) zostanie również w przyszłości stabilizatorem bezpieczeństwa energetycznego kraju i będzie pełnił ważną rolę w polskim miksie energetycznym w kolejnych latach. Stosowanie tego surowca wymaga inwestycji w nowe technologie niskoemisyjne, które w przypadku jednostek wytwórczych centralnie dysponowanych będą również wysokosprawne oraz inwestycje w wysokosprawną kogenerację. Należy podkreślić zasadność pełnego wykorzystania potencjału kogeneracji. W tym sektorze pracują co prawda jednostki kosztowniejsze w eksploatacji od elektrowni, ale pozwalające efektywniej i oszczędniej wykorzystywać paliwa oraz zmniejszać emisję dwutlenku węgla. Zgodnie z założeniami polityki energetycznej państwa należy wspierać i rozwijać gospodarkę niskoemisyjną w formie odnawialnych źródeł energii i energetyki jądrowej. Równocześnie nie należy zapominać o wspieraniu odtwarzania wycofywanych mocy w dużych elektrowniach systemowych pod warunkiem, że będą one wysokosprawne i niskoemisyjne.
The progressive processes of globalization and changes in the global, European and local economy require integrated efforts aimed at solving problems related to development at the national regional and the local level involving the environment, energy sources, climate and technological transformation issues. European Union Member States are given right to create an individual Energy mix. Coal will continue to play a major role in Poland’s energy mix during the next decades. Polish coal reserves can provide energy security for decades. Despite crude oil and natural gas growth in fuel consumption, coal will continue to be the stabilizer of energy security for the country and play an important role in Poland’s energy mix in the years to come. However, further coal consumption requires investments in low carbon technologies which are of high efficiency and in high-efficiency cogeneration. The validity of the full utilization of cogeneration potential should be highlighted. Operating cogeneration plants are more expensive than power plants but they are more efficient and generate less carbon emissions. In accordance with the assumptions of the Energy policy of Poland, a low-carbon economy with renewable Energy sources and nuclear Energy should be supported and developed, however the obsolete coal generators should be replaced with low-carbon high-efficient ones.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmienności temperatur w obiekcie doświadczalnym eksploatowanym z osłabieniem nocnym
Analysis of temperature variation in experimental building operating with night setback
Autorzy:
Basińska, M.
Koczyk, H.
Tematy:
fizyka budowli
regulacja pogodowa
regulacja jakościowa instalacji centralnego ogrzewania
building physics
central heating
Pokaż więcej
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Powiązania:
https://bibliotekanauki.pl/articles/362428.pdf  Link otwiera się w nowym oknie
Opis:
W artykule przedstawiono analizę zmienności temperatur wewnętrznych w pomieszczeniach budynku do- świadczalnego. Badano wpływ parametrów regulacji pogodowej na wybrane temperatury wewnętrzne. W czasie 3-tygodniowego okresu pomiarowego przeanalizowano 4-warianty nastawy regulatora. Analizy prowadziły do oceny jakości regulacji i utrzymania komfortu cieplnego.
Analysis of the variation of indoor and wall temperatures in the experimental building was presented. The effect of four different settings on weather-controlled control unit was monitored. Results obtained during three week research were used to assess regulation and thermal comfort quality.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania poboru energii cieplnej w obiektach szpitalnych
Analysis of heat energy consumption in the premises of a hospital
Autorzy:
Bujak, J.
Tematy:
szpital
pobór ciepła
centralne ogrzewanie
ciepła woda
para technologiczna
hospital
central heating
heat energy demand
Pokaż więcej
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Powiązania:
https://bibliotekanauki.pl/articles/236640.pdf  Link otwiera się w nowym oknie
Opis:
W pracy omówiono wyniki badań poboru ciepła w obiektach liczącego 650 łóżek Szpitala Wojewódzkiego we Włocławku, przeprowadzonych w latach 2003-2006. Oddzielnie określono pobór ciepła na potrzeby centralnego ogrzewania, instalacji ciepłej wody użytkowej i pary technologicznej. Na podstawie przeprowadzonych pomiarów wyznaczono średnioroczny pobór ciepła na potrzeby centralnego ogrzewania, ciepłej wody użytkowej oraz pary technologicznej w funkcji liczby łóżek szpitalnych. Wyznaczony na podstawie badań pobór cieplnej energii użytecznej przypadający na jedno łóżko szpitalne może być wykorzystany do projektowania nowych szpitali (o wielkości 600÷700 łóżek) oraz modernizacji obiektów istniejących - przede wszystkim do prognozowania zapotrzebowania na ciepło do różnych celów, określenia mocy cieplnej źródła ciepła, poszczególnych węzłów cieplnych, wielkości przyłączy itp. Przydatne mogą być też informacje dotyczące tzw. stałych i nisko-temperaturowych odbiorów ciepła w skali roku w postaci ciepłej wody użytkowej. Mogą one zostać wykorzystane do różnych analiz w nowo budowanych i istniejących dużych szpitalach poszukujących rozwiązań w zakresie optymalizacji zużycia energii cieplnej.
The object under study is the Provincial Hospital in Wloclawek, with 650 beds, which was analyzed for heat energy consumption in the time span of 2003 to 2006. Heat energy consumption for the systems of central heating, domestic hot water preparation and technological steam production was measured separately to calculate the mean yearly heat energy consumption for each of them as a function of the number of hospital beds. The heat consumption values per bed obtained via the above route may be of significant help in designing new hospitals (with a bed number ranging between 600 and 700) and modernizing the existing objects. Another major area where these values are applicable includes, inter alia, forecasting the heat demand for a variety of purposes, assessing the thermal power of the heat source, determining individual heat distribution centres, or establishing the capacity of the connection lines. The findings of the study about the so-called constant and low-temperature annual consumption of domestic hot water are expected to be particularly useful for the optimization of heat energy demand in large hospitals - those under construction and the existing ones.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of water-water type heat pump operation in a building object
Analiza pracy pompy ciepła typu woda-woda w obiekcie budowlanym
Autorzy:
Knaga, J.
Szul, T.
Tematy:
heating system
heat pump
central heating
hot domestic water
scroll type compressor
heat transfer coefficient
building
statistical analysis
Pokaż więcej
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Powiązania:
https://bibliotekanauki.pl/articles/793704.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents operation examination results of a heating system equipped with a heat pump, manufactured by the Sekut company, equipped with a scroll type compressor. The performed statistical analysis has shown a significant influence of external temperature and heat transfer coefficient to the COP value. Within the analysed period, the COP maintained a level of 2.6 at an average monthly temperature of -6°C, with a transfer coefficient of 15%.
W opracowaniu przedstawiono wyniki badań eksploatacyjnych systemy grzewczego wyposażonego w pompę ciepła wyprodukowaną przez firmę Sekut ze sprężarką typu scrol. Przeprowadzona analiza statystyczna wykazała istotny wpływ temperatury zewnętrznej, oraz wskaźnika przekazania ciepła na wartość COP. W analizowanym okresie COP kształtowało się na poziomie 2.6 przy średniej miesięcznej temperaturze –6OC i wskaźniku przekazania 15%.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies