Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "currents" wg kryterium: Temat


Tytuł:
The role of stray currents in the evolution of damage in transport systems
Autorzy:
Kałkowska, E
Tematy:
stray currents
electric currents
catenary
circuit
corrosion
erosion
resistance
Pokaż więcej
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Powiązania:
https://bibliotekanauki.pl/articles/135114.pdf  Link otwiera się w nowym oknie
Opis:
The aim of the present work is the influence of stray currents on transport systems, especially rail and city systems. Therefore, a study was conducted that simulated flow of stray currents on elements of the transportation system. Steel DOMEX, which has enhanced resistance to corrosion, was used as research material. It is rarely understood that transport systems can have reciprocal negative effects on each other. For example, the urban and long-distance rail transport systems influence the transmission systems (gas pipelines, information systems). A side effect of the functioning of railways is the formation of stray currents, which cause electrochemical corrosion in all undergrounded metal components. It has been demonstrated that the impact of stray currents on the metal parts is of corrosive nature, and their effects can be presented graphically and numerically. It has also been proven that the anodic potential causes a greater loss than the cathodic potential. Furthermore, the exposure to the elements, both in the process of corrosion and erosion, accelerates the destruction of the material.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The comparison of effectiveness of ultrasounds and interferential currents in rehabilitation of patients with spondyloarthrosis
Porównanie skuteczności ultradźwięków i prądów interferencyjnych w usprawnianiu pacjentów z chorobą zwyrodnieniową dolnego odcinka kręgosłupa
Autorzy:
Jaworek, Jolanta
Domagała, Agata
Barłowska-Trybulec, Marta
Wydawca:
Wydawnictwo Uniwersytetu Jagiellońskiego
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Stanowisko do diagnostyki zabezpieczeń różnicowoprądowych
The laboratory stand for testing of residual current devices
Autorzy:
Czapp, S.
Świsulski, D.
Tematy:
prądy różnicowe
prądy upływowe
zabezpieczenia różnicowoprądowe
residual currents
leakage currents
residual current devices
Pokaż więcej
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Powiązania:
https://bibliotekanauki.pl/articles/267978.pdf  Link otwiera się w nowym oknie
Opis:
W obwodach z urządzeniami elektronicznymi, a w szczególności przekształtnikami, należy się liczyć z odkształconymi prądami ziemnozwarciowymi. Może też występować znaczny przejściowy i/lub ustalony prąd upływowy. Ma to istotne znaczenie dla skuteczności ochrony przeciwporażeniowej i niezawodności zasilania, jeżeli zastosowano zabezpieczenia różnicowoprądowe. W skrajnych przypadkach zabezpieczenia te mogą w ogóle nie reagować na silnie odkształcony prąd różnicowy, natomiast mogą zbędnie wyzwalać, przy braku zagrożenia porażeniowego, jeżeli załączeniu urządzenia towarzyszy znaczny przejściowy prąd upływowy. W pracy przedstawiono stanowisko laboratoryjne, które umożliwia badanie zabezpieczeń różnicowoprądowych przy wybranych prądach różnicowych przewidzianych przez normy przedmiotowe oraz dodatkowo przy różnych przebiegach prądów spotykanych w praktyce, a nie przewidzianych przez normy przedmiotowe. Stanowisko umożliwia generowanie ustalonych prądów różnicowych oraz różnego typu prądów przejściowych. Zasadniczym elementem stanowiska jest generator, którego programowanie wykonuje się za pomocą dedykowanych aplikacji, a także środowiska LabVIEW. W pracy zaprezentowano również wyniki przykładowych badań.
In circuits with electronic equipment, especially with frequency converters distorted eartb. fault current may occur. That circuits are also characterised by transient and/or steady state leakage currents. Harmonics in the earth fault current have negative effect on tripping of residual current devices. In some cases sensitivity of residual current devices rapidly decreases and protection against electric shock is not effective. Transient and steady state leakage current may cause residual current devices nuisance tripping. In the paper a laboratory stand for residual current devices testing is presented. This stand enables to generate distorted residual currents whose shape are not covered by international standards but may occur in practice. The main element of the stand is a programmed generator. For programming the generator dedicated software is used. Also special application in LabVIEW enviroment was carried out. In the paper the example results of the laboratory testing of residual current devices are described as well.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of random walk in two-dimensional lattice graphs to describe influence of wind and sea currents on oil slick movement
Autorzy:
Guze, S.
Mazurek, J.
Smolarek, L.
Tematy:
random walk
oil spill
currents
Pokaż więcej
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Powiązania:
https://bibliotekanauki.pl/articles/244325.pdf  Link otwiera się w nowym oknie
Opis:
The concept of oil slick movement being influenced by wind and sea currents is elementary for the decision model of the distribution of large oil spill emergency control means at sea. The analysis of water area conditions such as wind and sea currents is elementary for the concept of oil slick movement. The article presents the model of oil slick movement under the influence of wind and sea currents. In building the model, random walk in two-dimensional lattice graphs has been used. The movement of oil slick is analysed in two ways. In the paper, the movement of the oil slick is analysed in two ways without wind and focus on surface sea currents and with wind and currents. Case one assumes no wind and focuses on surface sea currents only using random walk in a two-dimensional square grid graph. Case two assumes that wind is in place, so oil slick is moving due to surface sea currents and wind currents. The description of movement in case two is based on a two-dimensional lattice graph, which is a combination of a triangular grid graph and a hexagonal grid graph. The article also describes the basic assumptions of oil slick model: the definition of water area, oil slick and algorithm for rescue action to contain the oil spill. Oil slick movement concept is elementary for the decision model of oil spill control at sea. The model allows estimating the distance of oil slick from coastal areas.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Currents physical components (CPC) in circuits with nonsinusoidal voltages and currents. Part 1, Single-phase linear circuits
Autorzy:
Czarnecki, L. S.
Tematy:
nonsinusoidal voltages and currents
harmonics
power definitions
power phenomena
apparent
reactive
scattered
unbalanced currents or powers
Pokaż więcej
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Powiązania:
https://bibliotekanauki.pl/articles/262747.pdf  Link otwiera się w nowym oknie
Opis:
The paper summarizes the present state of discussions on power phenomena, power definitions and compensation in single-phase linear circuits. The main concepts developed over several decades on how various non-active powers in circuits with nonsinusoidal voltages and currents should be defined and compensated are presented along with a detailed discussion of these concepts. The paper presents also the concept of the single-phase load current decomposition into Currents' Physical Components (CPC) and its application for power definitions and compensation in such circuits. The paper is not addressed to scientists and experts on powers, but rather to common electrical engineers that sometimes face power related problems in nonsinusoidal systems.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies