Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "digital imaging" wg kryterium: Temat


Tytuł:
Analysis of voice quality parameters in patients with vestibular voice
Autorzy:
Kosztyła-Hojna, Bożena
Łobaczuk-Sitnik, Anna
Zdrojkowski, Maciej
Duchnowska, Emilia
Moskal-Jasińska, Diana
Kraszewska, Anna
Twarowska, Anna
Biszewska, Jolanta
Tematy:
vestibular voice
videolaryngostroboscopy
High Speed Digital Imaging
acoustic analysis
Pokaż więcej
Wydawca:
Index Copernicus International
Powiązania:
https://bibliotekanauki.pl/articles/1397791.pdf  Link otwiera się w nowym oknie
Opis:
Abstract Vestibular voice includes participation of larynx structures which are absent in physiological process. Vestibular phonation may be desired when vocal folds are damaged as in paralytic dysphonia, or undesired in marginal hyperfunction. Vestibular voice may result from psychogenic dysphonia – phononeurosis. The aim of the study is perceptive evaluation of vestibular voice, objective larynx visualization, acoustic and aerodynamic examination. The study included 40 patients: 20 with vestibular voice, 20 with euphonic voice. Voice quality has been evaluated using perceptual GRBAS scale. Endoscopic and stroboscopic larynx examination used Endo-STROB-EL-Xion GmbH with visual tract. High-Speed Digital Imaging (HSDI) and High Speed (HS) camera registered true vocal folds vibrations. Acoustic evaluation of voice with DiagnoScope Specjalista, DiagNova Technologies included analysis of F0, Jitter, Shimmer, NHR, nonharmonic components. MPT has been analyzed. In examined group, hoarseness (95%), roughness (75%) and voice strain (55%) have been recorded. Endoscopy revealed edema of vestibular folds with dilation of vessels covering glottis. Stroboscopy and HSDI confirmed coexistence of hyperfunctional (95%) or paralytic (5%) dysphonia. Acoustic assessment revealed increase in Jitter, Shimmer, NHR and decrease in F0 and MPT. The vestibular voice is observed most frequently in women with hyperfunctional dysphonia (phononeuroses) or in paralytic dysphonia. Visualization techniques confirm the coexistence of vestibular folds hypertrophy and edema with vibration disorders. In the perceptual assessment, vestibular voice was hoarse, rough and strained. Acoustic examination showed increase of Jitter, Shimmer, NHR, presence of nonharmonic components and decrease of F0 and MPT.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gentamicin determination using silver nanoparticles and smartphone-based detection
Autorzy:
Kubacki, Karol
Paluch, Justyna
Kozak, Joanna
Opis:
The paper describes developing a gentamicin determination method using silver nanoparticles (AgNPs) and smartphone-based detection. The study included selecting conditions for AgNPs’ synthesis using gallic acid as a natural stabilising and reducing agent, selecting conditions for AgNPs aggregation induced by gentamicin, such as aggregation time and AgNPs concentration, choosing the measuring channel for smartphone-based detection, and testing the possibility of using different smartphones. Spectrophotometry was used as a reference method. Analytical parameters for spectrophotometric and smartphone-based detection methods, like the linear range: 30.00–90.00 µg $dm^{−3}$, the limit of quantification: 30.00 µg $dm^{−3}$, the same for both methods, and precision (CV, n = 6) 6.5 and 2.6%, respectively, were determined. The selectivity of AgNPs under selected conditions against other antibiotics was also examined. The developed method was successfully applied to determine gentamicin in eye drop samples. Thanks to compact and accessible equipment and good analytical characteristics, it can become an alternative to other methods reported in the literature.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Phonatory compensation in patients with larynx cancer after CO2 laser cordectomy
Autorzy:
Kosztyła-Hojna, Bożena
Łuczaj, Jarosław
Berger, Greta
Duchnowska, Emilia
Zdrojkowski, Maciej
Łobaczuk-Sitnik, Anna
Biszewska, Jolanta
Tematy:
cordectomy
glottis cancer
high speed digital imaging
laryngeal compensation
Pokaż więcej
Wydawca:
Index Copernicus International
Powiązania:
https://bibliotekanauki.pl/articles/1397494.pdf  Link otwiera się w nowym oknie
Opis:
Introduction: CO2 laser endoscopic cordectomy is the method of laryngeal cancer treatment. The type of cordectomy (I–VI) depends on the extent of the tumor. Endoscopic laser surgery provides more satisfactory phonation conditions in comparison to open surgical procedures. The aim: The aim of the study was to classify phonatory compensation mechanisms after CO2 laser cordectomy using the HSDI. M aterial and methods: The study included 30 men treated and diagnosed at the Department of Otolaryngology and Department of Clinical Phonoaudiology and Logopedics, Medical University of Bialystok. The control included 30 men with no pathological changes in the larynx. Type III, IV and Va CO2 laser cordectomy have been for glottis cancer treatment. Postoperative evaluation has been conducted 6 months after the surgery. HSDI has been used in larynx visualization. R esults: Type I compensation occurs most frequently in patients after type III cordectomy. Advanced glottis cancer, as an indication for type IV and V cordectomy, leads to epiglottic hyperfunction and phonation involving vestibular folds – type II and III compensation. Type IV compensation is most frequent in type IV cordectomy. C onclusions: The type compensation is connected with the extent of glottis resection. In cordectomy including anterior commissure and the part of opposite fold (type Va), supraglottic hyperfunction with the participation of vestibular folds (type II and III compensation) has been recorded. Transmuscular cordectomy (type III) most often resulted in type I compensation. Type III-Va cordectomy caused reduction or absence of MW, decrease in amplitude and aperiodicity of vibrations in HSDI.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nad możliwością zastosowania systemu cyfrowego obrazowania w analizie środowiskowej
Research on the possibility of using a digital imaging system in environmental analysis
Autorzy:
Wnęk, Paulina
Opis:
Przedstawiona praca dotyczy opracowania metody umożliwiającej jednoczesne oznaczanie cynku i miedzi w próbkach środowiskowych z wykorzystaniem systemu cyfrowego obrazowania. W części literaturowej opisano cynk oraz miedź wraz z ich wzajemnymi oddziaływaniami. Został również scharakteryzowany sposób działania systemu cyfrowego obrazowania bazującego na użyciu aplikacji PhotoMetrix PRO wraz z metodami opisanymi w literaturze do oznaczania Zn i Cu oraz wykorzystanie systemów cyfrowego obrazowania do oznaczenia różnego rodzaju analitów w próbkach środowiskowych. W części doświadczalnej opisano przebieg badań, które objęły sprawdzenie możliwości oznaczania cynku i miedzi z 1-(2-pirydylazo)-2-naftolem (PANem) z wykorzystaniem systemu cyfrowego obrazowania wraz z wyznaczeniem parametrów walidacyjnych oraz sprawdzenie możliwości jednoczesnego oznaczania tych analitów poprzez zastosowanie procedury rozdzielania analitów lub z wykorzystaniem odpowiedniej metody kalibracyjnej. Przeprowadzone badanie pozwoliły na opracowanie metody jednoczesnego oznaczania Zn i Cu z wykorzystaniem kalibracji dwuskładnikowej bazującej na wykorzystaniu planu czynnikowego 2^2. Zaproponowaną metodę zweryfikowano na podstawie jednoczesnego oznaczania cynku i miedzi w próbkach syntetycznych oraz w certyfikowanym materiale odniesienia.
The presented work concerns the development of a method enabling the simultaneous determination of zinc and copper in environmental samples with the use of a digital imaging system. In the literature section, zinc and copper are discussed, including their mutual interactions. The application of the digital imaging system with the use of the PhotoMetrix PRO app, is also characterised, along with methods described in literature for the quantification of Zn and Cu, and the use of digital imaging systems for the determination of various analytes in environmental samples.The experimental part describes how the research was conducted, including the possible determination of zinc and copper concentration with 1-(2-pyridylazo)-2-naphthol (PAN), coupled with a digital imaging system detection, as well as the determination of validation parameters. It also discussed the possibility of simultaneous quantification of these analytes by applying a separation method or using an appropriate calibration method. The conducted study allowed for the development of a method for the simultaneous determination of Zn and Cu with the use of a two-factorial calibration based on the utilisation of the 2^2 factorial plan. The proposed method was verified by the simultaneous determination of zinc and copper in synthetic samples and in a certified reference material.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Inne
Tytuł:
Usefulness of high-speed digital imaging (HSDI) in the diagnosis of oedematous – hypertrophic changes of the larynx in people using voice occupationally
Autorzy:
Kosztyła-Hojna, Bożena
Moskal, Diana
Kuryliszyn-Moskal, Anna
Andrzejewska, Anna
Łobaczuk-Sitnik, Anna
Kraszewska, Anna
Skorupa, Małgorzata
Tematy:
High-Speed Digital Imaging
oedematous-hypertrophic changes
vocal fold mucosa
larynx
Pokaż więcej
Wydawca:
Index Copernicus International
Powiązania:
https://bibliotekanauki.pl/articles/1398519.pdf  Link otwiera się w nowym oknie
Opis:
Introduction. The aim of the study is the evaluation of the usefulness of High-Speed Digital Imaging (HSDI) in the diagnosis of organic dysphonia in a form of oedematous-hypertrophic changes of vocal fold mucosa, morphologically confirmed by Transmission Electron Microscopy (TEM) method in patients working with voice occupationally. Material and methods. The group consisted of 30 patients working with voice occupationally with oedematous-hypertrophic changes of vocal fold mucosa. Parameters of vocal folds vibrations were evaluated using HSDI technique with a digital HS camera, HRES Endocam Richard Wolf GmbH. The image of vocal folds was recorded with a rate of 4000 frames per second. Postoperative material of the larynx was prepared in a routine way and observed in transmission electron microscope OPTON 900–PC. Results. HSDI technique allows to assess the real vibrations of vocal folds and determine many parameters. The results of TEM in the postoperative material showed destruction of epithelial cells with severe vacuolar degeneration, the enlargement of intercellular spaces and a large number of blood vessels in the stroma, which indicates the presence of oedematous-hypertrophic changes of the larynx. Discussion. The ultrastructural assessment confirm the particular usefulness of HSDI method in the diagnosis of organic dysphonia in a form of oedematous-hypertrophic changes. Key words: High-Speed Digital Imaging, oedematous-hypertrophic changes, vocal fold mucosa, larynx
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical diagnostics in a spark ignition engine for two-wheel vehicles
Autorzy:
Merola, S. S.
Sementa, P.
Tornatore, C.
Tematy:
spark ignition engine
gasoline
2-wheel vehicle
optical diagnostics
digital imaging
spectroscopy
Pokaż więcej
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Powiązania:
https://bibliotekanauki.pl/articles/247811.pdf  Link otwiera się w nowym oknie
Opis:
Different optical techniques were applied to describe the thermal and chemical processes that occur in a SI small engine from the ported fuel injection and in-cylinder mixture formation to the combustion process and the exhaust emission. In PFI SI engines, the atomized fuel is sprayed towards the intake valves, where it may evaporate, puddle or rebound. Furthermore, a portion of the fuel may flow directly into the cylinder or impinge upon the port walls. These phenomena occur in varying degrees and depend upon the engine design, injector location and engine operation. Potentially the fuel can enter the cylinder in a poorly atomized state, leading to an increased unburned hydrocarbon emissions. This is particularly true during cold operation, when evaporation is low. In the small-motorcycle and scooter engines the fuel injection occurs in smaller intake manifold than light-duty vehicle engines, increasing the criticism of the fuel-wall interaction. The experimental investigations were performed in a single cylinder engine constituted by an elongated optically accessible piston and equipped with the head and injection system of a reference 4-stroke engine for small vehicles. High spatial resolution imaging was used to characterize the fuel injection phase. The cycle resolved visualization was performed to follow the flame propagation from the intake spark ignition to the exhaust phase. Natural emission spectroscopy measurements were applied in the ultraviolet-visible wavelength range to identify the chemical species that are markers of the combustion process and to follow the formation of pollutants.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testy systemu do obrazowania cyfrowego umożliwiającego pracę z promieniowaniem X o dużym natężeniu i selekcję energetyczną fotonów
Tests of system for digital imaging with the X-ray of high intensity and selection of photon energy
Autorzy:
Gryboś, P.
Maj, P.
Szczygieł, R.
Świentek, K.
Ramello, L.
Rodriguez, A.
Tematy:
układy ASIC
detektory krzemowe
techniki obrazowania cyfrowego
ASIC
silicon strip detectors
digital imaging
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/153098.pdf  Link otwiera się w nowym oknie
Opis:
W pracy przedstawiono budowę i wyniki testów zintegrowanego modułu do obrazowania cyfrowego umożliwiającego pracę z promieniowaniem X o dużym natężeniu i selekcje fotonów w zależności od ich energii. Elementem detekcyjnym modułu jest paskowy detektor krzemowy, z którego informacja jest odbierana i przetwarzana przez wielokanałowe specjalizowane układy scalone o architekturze binarnej. Uzyskane wyniki pomiarów 128 kanałowego modułu potwierdzają bardzo dobrą jednorodność poszczególnych kanałów, niski poziom szumów elektroniki odczytu oraz jej poprawną pracę również w przypadku bardzo dużej częstości impulsów wejściowych.
The paper presents construction and tests of integrated module for digital X-ray imaging. This module could work with high X-ray intensity and selects photons according their energy. The module consists of silicon strip detector and ASICs of binary architecture. The measurement results of 128-channel module show its good noise parameters, uniformity of analogue parameters of multichannel ASIC and its possibility to work with high rate of input pulses.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wybranych systemów obrazowania cyfrowego w mammografii
Comparison of chosen digital imaging systems in mammography
Autorzy:
Jakubowska, T.
Tematy:
mammografia cyfrowa
obrazowanie cyfrowe
DR
CR
digital mammography
digital imaging
dynamic replacement (DR)
computed radiography (CR)
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Powiązania:
https://bibliotekanauki.pl/articles/262184.pdf  Link otwiera się w nowym oknie
Opis:
Mammografia jest najbardziej czułym i specyficznym badaniem w diagnozowaniu raka sutka. Zastosowanie techniki cyfrowej CR (Computed Radiography) i DR (Digital Radiography) ma na celu poprawę jakości obrazów, a co za tym idzie poprawę wykrywalności zmian przy jednoczesnym skróceniu czasu badania i obniżeniu dawki promieniowania. Niniejsza praca przedstawia porównanie stosowanych obecnie w mammografii wybranych systemów cyfrowych pod względem jakości obrazowania, jak również stosowanych dawek.
Mammography is a most sensitive and specific examination used in the breast cancer diagnosis. Digital radiographic systems CR (Computed Radiography) and DR (Digital Radiography) offer the high quality imaging with shorter exposure times, thus lowering the radiation dose. In this paper, the comparison of frequently used mammographic digital systems in terms of the imaging quality and doses applied, is presented.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nad opracowaniem zintegrowanego systemu detekcyjnego do oznaczania litu
Research on the development of an integrated detection system for the determination of lithium
Autorzy:
Serwin, Anna
Opis:
W pracy został przedstawiony przebieg badań nad opracowaniem zintegrowanego systemu detekcyjnego z wykorzystaniem smartfona do oznaczania litu. Wstęp teoretyczny pracy zawiera opisy przykładów zastosowania zintegrowanych systemów detekcyjnych w analizie chemicznej. Podstawą prowadzonych pomiarów była reakcja litu z chinizaryną, w wyniku której powstawał barwny kompleks. W badaniu porównano wyniki otrzymane dla ośmiu kanałów w aplikacji PhotoMetrix PRO, które odpowiadają składowym koloru w różnych przestrzeniach barw. Wyznaczone zostały zakresy liniowości metody, wartości granicy wykrywalności i oznaczalności oraz dokładność (określona przez wartość błędu względnego) i precyzja (określona przez wartość względnego odchylenia standardowego) dla wszystkich kanałów. Na podstawie uzyskanych wyników wybrano kanał H, który określa odcień barwy, jako najbardziej optymalny do prowadzenia oznaczania litu zaproponowaną metodą pod kątem analizy próbek surowicy.
In this paper, the development of an integrated detection system using a smartphone for the determination of lithium is presented. The theoretical introduction of the work includes descriptions of examples of the application of integrated detection systems in chemical analysis. The basis of the conducted measurements co was the reaction of lithium with quinizarin, resulting in the formation of a coloured complex. The study compared the results obtained for eight channels in the PhotoMetrix PRO application, which correspond to color components in different color spaces. The ranges of linearity of the method, the values of the limit of detection and determination, as well as the accuracy (defined by the value of relative error) and precision (defined by the value of relative standard deviation) for all channels were determined. Based on the obtained results, the H channel, which defines the color shade, was selected as the most optimal channel for conducting lithium determination by the proposed method in terms of analysing serum samples.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Inne

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies