Fault-tolerant control for three-phase three-level T-type inverters with a redundant leg
Autorzy:
Chen, Danjiang
Zheng, Liyuan
Tematy:
fault diagnosis
fault-tolerant control
open-circuit fault
phase-leg fault
redundant leg
T-type inverter
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/2172799.pdf  Link otwiera się w nowym oknie
Opis:
Three-level T-type inverters have lower total harmonic distortion in output voltage, higher power density and lower voltage stress of power switches compared with conventional two-level inverters and have been widely used in applications with a wide-power range. Reliability improvement is particularly important for the T-type inverters because of the increased number of power switches and high system complexity. This paper proposes a fault-tolerant topology, which is constructed by adding a redundant leg including halfbridge switches and neutral-point switches connected between the DC bus capacitors and the DC-link midpoint of the conventional T-type inverter. In addition, an after-fault control strategy is proposed based on the results of a fault diagnosis method using bridge voltage. The fault-tolerant control of the open-circuit fault of the power switches and the phase-leg fault can both be achieved by the proposed method. Experimental results are given to verify that the proposed fault-tolerant three-level T-type inverter can output the full voltage level and power during the fault-tolerant operation based on the proposed control strategy.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Location of arc faults on power transmission lines
Autorzy:
Pustułka, M
Iżykowski, J
Łukowicz, M
Tematy:
arc fault
fault location
signal processing
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/410527.pdf  Link otwiera się w nowym oknie
Opis:
This paper presents a fault location algorithm, which allows to determine the distance to a fault and fault resistance, as a result of considering natural fault loops. It is assumed that three-phase voltages and currents from both ends of the line measured asynchronously are the input signals of the fault locator. In case of the availability of synchronized measurements the elements associated with the determination of the synchronization angle should be omitted. In addition to natural fault loop signals also use of symmetrical components (positive and negative or incremental positive sequence components) to fault location were considered as well.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study by modeling and simulation of open-switch fault diagnosis for five-level converters
Autorzy:
Becker, F.
Jamshidpour, E.
Poure, P.
Saadate, S.
Tematy:
open switch fault
fault diagnosis
fault detection
fault localization
Multilevel converter
neutral point
H-bridge
Pokaż więcej
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Powiązania:
https://bibliotekanauki.pl/articles/136241.pdf  Link otwiera się w nowym oknie
Opis:
In this paper, an open-switch fault diagnosis method for five-level H-Bridge Neutral Point Piloted (HB-NPP) or T-type converters is proposed. While fault tolerant operation is based on three steps (fault detection, fault localization and system reconfiguration), a fast fault diagnosis, including both fault detection and localization, is mandatory to make a suitable response to an open-circuit fault in one of the switches of the converter. Furthermore, fault diagnosis is necessary in embedded and safety critical applications, to prevent further damage and perform continuity of service. In this paper, we present an open-switch fault diagnosis method, based on the switches control orders and the observation of the converter output voltage level. In five-level converters such as HB-NPP and T-type topologies, some switches are mostly 'on' at the same time. Therefore, the fault localization is quite complicated. The fault diagnosis method we proposed is capable to detect and localize an open-switch fault in all cases. Computer simulations are carried out by using Matlab Simulink and SimPowerSystem toolbox to validate the proposed approach.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of a guaranteed minimum detectable sensor fault diagnosis scheme
Autorzy:
Witczak, Marcin
Pazera, Marcin
Majdzik, Paweł
Matysiak, Ryszard
Tematy:
minimum detectable fault
fault estimation
fault diagnosis
sensor fault
estymacja błędu
diagnostyka uszkodzeń
błąd czujnika
Pokaż więcej
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Powiązania:
https://bibliotekanauki.pl/articles/59123781.pdf  Link otwiera się w nowym oknie
Opis:
The paper deals with the estimation of sensor faults for dynamic systems as well as the assessment of the uncertainty of the resulting estimates. For that purpose, it is assumed that the external disturbances are bounded within an ellipsoidal domain. This allows considering both stochastic and deterministic process and measurement uncertainties. Under such an assumption, a fault diagnosis scheme is developed with a prescribed convergence rate and accuracy. To achieve fault estimation, a conversion into an equivalent descriptor system is utilized. The paper provides a full stability and convergence analysis of the estimator including observability analysis. As a result, a set of complementary fault uncertainty intervals is obtained, which are minimized in such a way as to obtain a minimum detectable sensor fault. The final part of the paper exhibits a numerical example concerning fault estimation of a multi-tank system. The obtained results clearly confirm the performance of the proposed estimator expressed in the minimum detectable fault intervals.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytm minimalizacji sygnatur uszkodzeń
The algorithm of fault signatures minimization
Autorzy:
Chalecki, D.
Tematy:
diagnostyka
uszkodzenie
lokalizacja uszkodzeń
sygnatura uszkodzenia
diagnostic testing
fault isolation
fault signature
fault
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Powiązania:
https://bibliotekanauki.pl/articles/327300.pdf  Link otwiera się w nowym oknie
Opis:
W pracy przedstawiono metodę minimalizacji sygnatur uszkodzeń jako jedno z rozwiązań problemów związanych z dużą liczbą sygnałów pomiarowych, wykorzystywanych testów i potencjalnych uszkodzeń w złożonych instalacjach technologicznych. Jego opracowanie ma na celu skrócenie czasu lokalizacji uszkodzeń w takich instalacjach. W referacie opisano różnicę pomiędzy pełnymi sygnaturami uszkodzeń a sygnaturami zredukowanymi oraz przedstawiono poszczególne kroki realizacji algorytmu, na podstawie którego można uzyskać sygnatury zredukowane.
The paper presents a method of minimization of fault signatures as a solution of a problem concerning large number of measuring signals and potential faults in compound technological systems. The aim of elaboration of the algorithm is to shorten the time of fault isolation in such systems. The paper describes the difference between full and reduced fault signatures as well as presents individual steps of realization of the algorithm enabling to obtain the reduced signatures.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Faulted feeder identification and location for a single line-to-ground fault in ungrounded distribution system based on principal frequency component
Autorzy:
Liu, Ling
Tematy:
fault identification
fault location
single line-to-ground fault
principal frequency component
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/141574.pdf  Link otwiera się w nowym oknie
Opis:
When a single line-to-ground fault occurs in the ungrounded distribution system, the steady-state fault current is relatively small for fault analysis and the transient fault current is observable, which can be used for faulted feeder identification and location. The principal frequency component retains most of the characteristics of the transient current. The principal frequency is related to the distance from the fault point to the substation and can be used for fault location. This paper analyzes the sequence network model of a single line-to-ground fault in the distribution network, and gives a method for principal frequency calculation. Depending on the characteristics of the maximum amplitude of the principal frequency component of the faulted feeder, the method of faulted feeder identification is given. Based on the complementary characteristics of the phase angle of the principal frequency component of the fault current and the phase angle at the substation bus, the faulted section location is carried out. MATLAB simulation is used to verify the effectiveness of the faulted feeder identification and location method.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling and fault-tolerant control of 5-phase induction machine
Autorzy:
Rolak, M.
Che, H. S.
Malinowski, M.
Tematy:
multiphase machine
fault tolerant
post-fault
fault detection
tolerancja błędu
detekcja błędu
maszyny wielofazowe
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/202453.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents modeling and analysis of a 5-phase induction machine connected to 2-level 5-leg converter in case of open-phase failure. A control of the machine is accomplished using the Field Oriented Control with hysteresis current controllers. Moreover, a fault-tolerant algorithm is addressed and simulated.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Key fault propagation path identification of CNC machine tools based on maximum occurrence probability
Autorzy:
Zhang, Yingzhi
Zhou, Yutong
Yang, Fang
Wang, Zhiqiong
Sun, Mo
Tematy:
fault propagation
CNC machine tools
key fault propagation path
improved Pagerank
fault propagation probability
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Powiązania:
https://bibliotekanauki.pl/articles/27312788.pdf  Link otwiera się w nowym oknie
Opis:
In order to revise the deviation caused by ignoring the dynamic character of fault propagation in traditional fault propagation path identification methods, a method based on the maximum occurrence probability is proposed to identify the key fault propagation path. Occurrence probability of fault propagation path is defined by dynamic importance, dynamic fault propagation probability and fault rate. Taking the fault information of CNC machine tools whichsubject to Weibull distribution as an example, this method has been proven to be reasonable through comparative analysis. Result shows that the key fault propagation path of CNC machine tools is not unique, but changes with time. Before 1000 hours, key fault propagation path is electrical component (E) to mechanical component (M); after 1000 hours, key fault propagation path is auxiliary component (A) to mechanical component (M). This change should be taken into account when developing maintenance strategies and conducting reliability analysis.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neural network filtration for arc faults location on power transmission lines
Autorzy:
Pustułka, M.
Iżykowski, J.
Łukowicz, M.
Tematy:
arc fault
fault location
signal processing
filtration
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/410589.pdf  Link otwiera się w nowym oknie
Opis:
This paper presents filtration using neural network for arc fault location, which allows to determine the distance to a fault, as a result of considering natural fault loops. It is assumed that three-phase voltages and currents from both ends of the line are the input signals of the fault locator and naturally of the neutral network applied for filtering the input signals. In addition to natural fault loop signals also use of symmetrical components (positive and negative or incremental positive sequence components) to fault location were considered as well. Results of evaluation study have been included, analyzed and discussed. Influence of filtration has been also considered.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Systematic fault tolerant control based on adaptive Thau observer estimation for quadrotor UAVs
Autorzy:
Cen, Z.
Noura, H.
Younes, Y. A.
Tematy:
systematic fault tolerant control
fault estimation
adaptive Thau observer
fault tolerant capacity boundaries
time varying fault
sterowanie tolerujące uszkodzenia
estymacja błędu
Pokaż więcej
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Powiązania:
https://bibliotekanauki.pl/articles/329914.pdf  Link otwiera się w nowym oknie
Opis:
A systematic fault tolerant control (FTC) scheme based on fault estimation for a quadrotor actuator, which integrates normal control, active and passive FTC and fault parking is proposed in this paper. Firstly, an adaptive Thau observer (ATO) is presented to estimate the quadrotor rotor fault magnitudes, and then faults with different magnitudes and time-varying natures are rated into corresponding fault severity levels based on the pre-defined fault-tolerant boundaries. Secondly, a systematic FTC strategy which can coordinate various FTC methods is designed to compensate for failures depending on the fault types and severity levels. Unlike former stand-alone passive FTC or active FTC, our proposed FTC scheme can compensate for faults in a way of condition-based maintenance (CBM), and especially consider the fatal failures that traditional FTC techniques cannot accommodate to avoid the crashing of UAVs. Finally, various simulations are carried out to show the performance and effectiveness of the proposed method.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies