Tytuł:
Application of the micronucleus assay performed by different scorers in case of large-scale radiation accidents
Autorzy:
Rawojć, K.
Tarnawska, D. M.
Miszczyk, J. U.
Swakoń, J.
Stolarczyk, L.
Rydygier, M.
Tematy:
biological dosimetry
cytokinesis-blocked micronucleus assay
frequency of micronuclei
Pokaż więcej
Wydawca:
Instytut Chemii i Techniki Jądrowej
Powiązania:
https://bibliotekanauki.pl/articles/146534.pdf  Link otwiera się w nowym oknie
Opis:
Mass casualty scenarios of radiation exposure require high throughput biological dosimetry techniques for population triage, in order to rapidly identify individuals, who require clinical treatment. Accurate dose estimates can be made by biological dosimetry, to predict the acute radiation syndrome (ARS) within days after a radiation accident or a malicious act involving radiation. Timely information on dose is important for the medical management of acutely irradiated persons [1]. The aim of the study was to evaluate the usefulness of the micronuclei (MNi) scoring procedure in an experimental mode, where 500 binucleated cells were analyzed in different exposure dose ranges. Whole-body exposure was simulated in an in vitro experiment by irradiating whole blood collected from one healthy donor with 60 MeV protons and 250 keV X-rays, in the dose range of 0.3–4.0 Gy. For achieving meaningful results, sample scoring was performed by three independent persons, who followed guidelines described in detail by Fenech et al. [2, 3]. Compared results revealed no signifi cant differences between scorers, which has important meaning in reducing the analysis time. Moreover, presented data based on 500 cells distribution, show that there are significant differences between MNi yields after 1.0 Gy exposure of blood for both protons and X-rays, implicating this experimental mode as appropriate for the distinction between high and low dose-exposed individuals, which allows early classification of exposed victims into clinically relevant subgroups.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of cells response to different biomarkers in PCC and MN tests in response to X-rays (250 kVA) and 60 MeV proton beam
Porównanie odpowiedzi limfocytów dla różnych biomarkerów w testach PCC i MN w odpowiedzi na promieniowanie X (250 kV) i 60 MeV protony
Autorzy:
Możdżeń, Iwona
Opis:
The aim of this study was to compare the cells response to various biomarkers in a test of premature chromosome condensation and the micronucleus test in response to X-rays (250kVA) and proton beam (60 MeV).Biological material used for this purpose were obtained from peripheral blood donors. The biological dosimetry, there are tests that make use of biological material such peripheral whole blond, e.g. CA, FISH, but more often introduced into the test using isolated lymphocytes from whole peripheral blood, for example PCC version fusion CHO cells (Chinese Ovary Chamster).The first task adopted for carrying out the above objective was to check whether there is a difference in the response of cells isolated with respect to the cells of peripheral whole blood. The analysis was conducted using markers of (the number of redundant chromosomal elements, the frequency of micronuclei and an nuclear division index) and the different types of radiation. The next task was to check whether there are differences in analysis between two people.From the first donor material portion irradiated with X-rays, and the second - proton beam. Dosages were used in the range of 0.3 - 4.0 Gy. The remainder of the material is not irradiated, treating it as a control. Exposure of cells to X-ray used X-ray flash MCN 323 Philips, which is the equipment of the Department of Experimental Physics of Complex Systems IFJ. Irradiation cell proton beam was done using cyclotron Proteus C-235 company Ion Beam Applications.On the basis of the identified biomarkers curves of the dose-effect that they can be used not only to characterize the response of lymphocytes whole blood and isolated, but also to study patients in response to different types of radiation, development and optimization methods PCC (version using isolated lymphocytes and their fusion CHO cells), as well as for use at the proton radiotherapy and further development of methods of biological dosimetry.
Celem niniejszej pracy było porównanie odpowiedzi limfocytów dla różnych biomarkerów w teście przedwczesnej kondensacji chromosomów i teście mikrojądrowym w odpowiedzi na promieniowanie X (250kV) i protony (60 MeV). Materiałem biologicznym wykorzystywanym w tym celu była krew obwodowa pobrana od jednego dawcy. W dozymetrii biologicznej istnieją testy, które jako materiał biologiczny wykorzystują pełną krew obwodowa np. CA, FISH, ale coraz częściej wprowadza się testy z wykorzystaniem izolowanych limfocytów z pełnej krwi obwodowej, np. PCC wersja z fuzją komórek CHO (Chinese Chamster Ovary).Pierwszym zadaniem przyjętym dla zrealizowania powyższego celu było sprawdzenie, czy istnieje różnica w odpowiedzi komórek izolowanych w odniesieniu do komórek pełnej krwi obwodowej. Analizę te przeprowadzono z wykorzystaniem wybranych biomarkerów (liczba nadmiarowych elementów chromosomów, częstość występowania mikrojąder oraz indeks proliferacji komórkowej) i dla różnych typów promieniowania. Kolejnym zadaniem było sprawdzenie, czy istnieją różnice w analizie pomiędzy dwoma osobami. Od wybranego dawcy pierwszą część materiału naświetlono promieniowaniem rentgenowskim, a drugą – wiązką protonową. Zastosowano dawki w zakresie 0,3 – 4,0 Gy. Pozostałą część materiału nie naświetlano, traktując ją jako próbę kontrolną. Do naświetlenia komórek promieniowaniem X wykorzystano aparat rentgenowski z lampą MCN 323 firmy Philips, stanowiący wyposażenie Zakładu Fizyki Doświadczalnej Układów Złożonych IFJ PAN. Napromienianie komórek wiązką protonową odbywało się z wykorzystaniem cyklotronu Proteus C-235 firmy Ion Beam Applications. Na podstawie oznaczonych biomarkerów wyznaczono krzywe dawka-efekt, które będą mogły służyć nie tylko do charakteryzowania odpowiedzi limfocytów pełnej krwi i izolowanych, ale także do badania odpowiedzi pacjentów na różne typy promieniowania, opracowania i optymalizacji metody PCC (wersja z użyciem izolowanych limfocytów i ich fuzji z komórkami CHO), a także dla potrzeb stosowania na stanowisku radioterapii protonowej oraz dalszemu rozwojowi metod dozymetrii biologicznej.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Inne
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies