Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "image compression" wg kryterium: Temat


Tytuł:
Compression of image sequences in interactive medical teleconsultations
Autorzy:
Malawski, F.
Czekierda, Ł.
Tematy:
image compression
medical teleconsultations
telemedicine
Pokaż więcej
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Powiązania:
https://bibliotekanauki.pl/articles/305585.pdf  Link otwiera się w nowym oknie
Opis:
Interactive medical teleconsultations are an important tool in modern medical practice. Their applications include remote diagnostics, conferences, work- shops, and classes for students. In many cases, standard medium or low-end machines are employed, and the teleconsultation systems must be able to provide a high quality of user experience with very limited resources. Particularly problematic are large datasets consisting of image sequences that need to be accessed fluently. The main issue is insufficient internal memory; therefore, proper compression methods are crucial. However, a scenario where image sequences are kept in a compressed format in the internal memory and decompressed on- the-fly when displayed is difficult to implement due to performance issues. In this paper, we present methods for both lossy and lossless compression of medical image sequences that only require compatibility with the Pixel Shader 2.0 standard, which is present even on relatively old, low-end devices. Based on the evaluation of quality, size reduction, and performance, these methods have been proven to be suitable and beneficial for medical teleconsultation applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Irreversible medical image compression: conditions of acceptability
Autorzy:
Przelaskowski, A.
Tematy:
irreversible compression
medical image compression
diagnostic accuracy
diagnostic image quality
Pokaż więcej
Wydawca:
Politechnika Gdańska
Powiązania:
https://bibliotekanauki.pl/articles/1965779.pdf  Link otwiera się w nowym oknie
Opis:
Acceptance of irreversible image compression applicable to medical imagery is controversial in the medical community. The influence of this irreversible process on degradation of diagnostic image features is considered and how to preserve diagnostic accuracy. Fears, doubts, the disadvantages of the data distortion process and the advantages of safe and efficient irreversible compression for image information storage and interchange are discussed. The effects of compression on various image exams are analysed. The conclusion is that irreversible compression is not to be afraid of, but its characteristics should be well understood before implementing it in current practice.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Image compression-encryption algorithm combining compressive sensing with log operation
Autorzy:
Chen, R.-L.
Zhou, Y.
Luo, M.
Zhang, A.-D.
Gong, L.-H.
Tematy:
image encryption
image compression
compressive sensing
log operation
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/174009.pdf  Link otwiera się w nowym oknie
Opis:
Based on compressive sensing and log operation, a new image compression-encryption algorithm is proposed, which accomplishes encryption and compression simultaneously. The proposed image compression-encryption algorithm takes advantage of not only the physical realizability of partial Hadamard matrix, but also the resistance of the chosen-plaintext attack since all the elements in the partial Hadamard matrix are 1, –1 or log 1 = 0. The proposed algorithm is sensitive to the key and it can resist various common attacks. The simulation results verify the validity and reliability of the proposed image compression-encryption algorithm.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shape Independent Coding Using NURBS and Bézier Approximation and Interpolation Curves
Autorzy:
Ondrušová, S.
Polec, J.
Tematy:
NURBS
Bezier
image compression
segmentation
shape independent transform
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/227081.pdf  Link otwiera się w nowym oknie
Opis:
In this paper a scheme of utilizing shape independent basis functions for the hierarchical multiresolution image compression is shown. For a given image texture region segmentation method is used. Following polygonal approximation of created segments causes a degradation of their boundaries. Using NURBS and Bezier interpolation and approximation segments' boundaries are created, thus achieving an image mask. As an input of the three-level hierarchical encoder this image mask and image are used. The image mask and image are subsampled by a factor of 2 on each level. The hierarchical encoder encodes them shape independently. Especially for a very low bit rate image coding gives better results for objective criteria (PSNR). For segment approximation the 2D shape independent orthogonal transform (DCT II) is used. Splines encoding and decoding is very efficient, because only their control points need to be stored. The segment is coded with a modified code similar to the JPEG code.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Image compression and encryption algorithm with wavelet-transform-based 2D compressive sensing
Autorzy:
Fan, Jing-Hui
Liu, Xian-Bao
Chen, Yan-Bin
Tematy:
wavelet transform
compressive sensing
chaos scrambling
image encryption
image compression
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/175122.pdf  Link otwiera się w nowym oknie
Opis:
By combining a wavelet transform with chaos scrambling, an image compression and encryption algorithm based on 2D compressive sensing is designed. The wavelet transform is employed to obtain the sparse representation of a plaintext image. The sparse image is measured in two orthogonal directions by compressive sensing. Then, the result of 2D compressive sensing is confused by the Arnold transform and the random pixel scrambling. The combination of four-dimensional chaos and logistic map is exploited to generate the first row of the key-controlled circulant matrix. The proposed algorithm not only carries out image compression and encryption simultaneously, but also reduces the consumption of the key by controlling the generation of measurement matrix. Experimental results reveal that the proposed image compression and encryption algorithm is resistant to noise attacks with good compression performance and high key sensitivity.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kapsułka endoskopowa nowej generacji
New generation capsular endoscopy
Autorzy:
Turcza, P.
Duplaga, M.
Tematy:
endoskopia kapsułkowa
kompresja
transmisja
capsular endoscopy
image compression
transmission
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/154903.pdf  Link otwiera się w nowym oknie
Opis:
W artykule przedstawiono wyniki prac realizowanych w ramach projektu VECTOR finansowanego w ramach 6 Programu Ramowego Unii Europejskiej w zakresie systemów kompresji i bezprzewodowej transmisji danych i obrazu dedykowanych dla endoskopii kapsułkowej nowej generacji. Opracowany system umożliwia transmisję 24 obrazów na sekundę o rozdzielczości 320x240 przez łącze radiowe o przepustowości 2 Mbit/s. Możliwość długotrwałej pracy kapsułki ma zapewnić układ zasilania bezprzewodowego zdolny dostarczyć do 300 mW mocy.
The paper discusses the outcomes of the European Project VECTOR FP6 concerning image compression and wireless data transmission systems dedicated to a new generation of capsule endoscopy. The overview of the developed system is given in Section 2. The image compressor algorithm, developed within the project, is presented briefly in the first part of Section 3. Next, a new adaptive entropy encoder proposed for it is discussed in detail. The new encoder, in comparison to the previous one, has much lower memory footprint, as it does not use Huffman tables. Simulation results given in Tab. 1 clearly demonstrate that the new encoder, despite its low implementation complexity, outperform the old one. The developed image compressor algorithm was implemented in a single, 65 nm ultra low-power FPGA. It operates with 24 MHz clock and it is able to process a single image frame in 8.2 ms. Its energy consumption amounts to 0.4 mJ per single compressed frame. In Section 4 a wireless transmission system for wireless capsular endoscopy is presented. In this section an improved demodulator for a wireless receiver is also proposed. Section 5 contains the conclusions.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Ingenious Application-Specific Quality Assessment Methods for Compressed Wireless Capsule Endoscopy Images
Autorzy:
Fante, Kinde Anlay
Abdurahman, Fetulhak
Gemeda, Mulugeta Tegegn
Tematy:
image quality assessment
wireless capsule endoscopy
compressed images
image compression
Pokaż więcej
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Powiązania:
https://bibliotekanauki.pl/articles/136180.pdf  Link otwiera się w nowym oknie
Opis:
Image quality assessment methods are used in different image processing applications. Among them, image compression and image super-resolution can be mentioned in wireless capsule endoscopy (WCE) applications. The existing image compression algorithms for WCE employ the generalpurpose image quality assessment (IQA) methods to evaluate the quality of the compressed image. Due to the specific nature of the images captured by WCE, the general-purpose IQA methods are not optimal and give less correlated results to that of subjective IQA (visual perception). This paper presents improved image quality assessment techniques for wireless capsule endoscopy applications. The proposed objective IQA methods are obtained by modifying the existing full-reference image quality assessment techniques. The modification is done by excluding the noninformative regions, in endoscopic images, in the computation of IQA metrics. The experimental results demonstrate that the proposed IQA method gives an improved peak signal-tonoise ratio (PSNR) and structural similarity index (SSIM). The proposed image quality assessment methods are more reliable for compressed endoscopic capsule images.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kompresja obrazów z wykorzystaniem kompresji fraktalnej i systemu funkcji iterowanych
Autorzy:
Stasiełowicz, M.
Tematy:
kompresja fraktalna
kompresja obrazów
kompresja stratna
fraktal
fractal compression
image compression
lossy compression
fractal
Pokaż więcej
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Powiązania:
https://bibliotekanauki.pl/articles/118331.pdf  Link otwiera się w nowym oknie
Opis:
Pod pojęciem kompresji obrazów kryją się najróżniejsze algorytmy kompresji danych. Najczęściej są to algorytmy kompresji stratnej, które charakteryzują się znacznym stopniem kompresji, lecz ich wadą jest utrata informacji podczas procesu kompresji. W niniejszym artykule zostanie opisany algorytm kompresji fraktalnej, który zalicza się do algorytmów kompresji stratnej i najczęściej wykorzystywany jest przy kompresji obrazów. Zostanie również przedstawiony opisu działania algorytmu z wykorzystaniem systemu funkcji iterowanych oraz jego wady i zalety. Celem artykułu jest porównanie możliwości kompresji metodą fraktalną z najpopularniejszą obecnie metodą kompresji stratnej obrazów JPEG. Uzyskane dane posłużą do dalszej analizy możliwości algorytmu kompresji fraktalnej oraz metod jego optymalizacji.
The term image compression hides various data compression algorithms. Usually these are lossy compression algorithms, which characterize high degree of compression, but their disadvantage is the loss of information during compression process. The article describes fractal compression algorithm, which is one of the lossy compression algorithms and is used mostly in image compression. It will be also described algorithm details using iterated function system and its advantages and disadvantages. The aim of the article is to compare the capabilities of fractal compression method with JPEG which is currently the most popular method of lossy image compression. The obtained data will be used to further analyze possibilities of fractal compression and methods of its optimalization.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytm kompresji obrazów dla bezprzewodowej kapsuły endoskopowej
Image compression algorithm for wireless endoscopy capsule
Autorzy:
Turcza, P.
Duplaga, M.
Tematy:
kompresja obrazów
kapsuła endoskopowa
image compression
video endoscopy capsule
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/155607.pdf  Link otwiera się w nowym oknie
Opis:
Artykuł prezentuje algorytm kompresji obrazów planowany do zastosowania w bezprzewodowej kapsule ednoskopewj. Algorytm przeznaczony do tego typu zastosowań oprócz możliwie wysokiego stopnia kompresji musi cechować się bardzo niskim poborem mocy. To wymaganie wyklucza użycie standardowych metod. Proponowany algorytm oparty jest o całkowitoliczbowe wersje transformacji DCT i transformacji falkowej oraz koder Huffmana. W porównaniu do algorytmów konkurencyjnych proponowany algorytm oferuje znacznie większy stopień kompresji przy nieco większej (głównie pamięciowej) złożoności.
The paper describes image compression algorithm suitable for wireless capsule endoscopy. Due to power limitation and small size conditions traditional image compression techniques are not appropriate and dedicated ones are neccessary. The proposed algorithm is based on integer version of discrete cosine transform (DCT) and wavelet transform (DWT) with Huffman entropy coder. Thanks to integer DCT/wavelet application it has low complexity and power consumption. Additionally, the algorithm can provide lossless compression as well as high-quality lossy compression.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of mammogram compression efficiency
Ocena efektywności kompresji mammogramów
Autorzy:
Kukuła, Anna
Surowski, Paweł
Przelaskowski, Artur
Opis:
Background: Lossy image coding significantly improves performance over lossless methods, but a reliable control of diagnostic accuracy regarding compressed images is necessary. The acceptable range of compression ratios must be safe with respect to as many objective criteria as possible. This study evaluates the compression efficiency of digital mammograms in both numerically lossless (reversible) and lossy (irreversible) manner. Effective compression methods and concepts were examined to increase archiving and telediagnosis performance. Materials/Methods Lossless compression as a primary applicable tool for medical applications was verified on a set 131 mammograms. Moreover, nine radiologists participated in the evaluation of lossy compression of mammograms. Subjective rating of diagnostically important features brought a set of mean rates given for each test image. The lesion detection test resulted in binary decision data analyzed statistically. The radiologists rated and interpreted malignant and benign lesions, representative pathology symptoms, and other structures susceptible to compression distortions contained in 22 original and 62 reconstructed mammograms. Test mammograms were collected in two radiology centers for three years and then selected according to diagnostic content suitable for an evaluation of compression effects. Results: Lossless compression efficiency of the tested coders varied, but CALIC, JPEG-LS, and SPIHT performed the best. The evaluation of lossy compression effects affecting detection ability was based on ROC-like analysis. Assuming a two-sided significance level of p=0.05, the null hypothesis that lower bit rate reconstructions are as useful for diagnosis as the originals was false in sensitivity tests with 0.04 bpp mammograms. However, verification of the same hypothesis with 0.1 bpp reconstructions suggested their acceptance. Moreover, the 1 bpp reconstructions were rated very similarly to the original mammograms in the diagnostic quality evaluation test, but the quality of 0.6 bpp and 0.1 bpp reconstructions was decreased. Conclusions: The compression performance of the most effective reversible coders is rather unsatisfactory. The subjective rating with the diagnostic criteria of image quality was more sensitive to distortions caused by lossy compression compared with the pathology detection test. The observers constituted 14:1 as the accepted ratio of lossy wavelet compression for test mammograms. This is significantly higher than the mean ratio of 2:1 achieved with lossless methods.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Image compression and encryption algorithm based on advanced encryption standard and hyper-chaotic system
Autorzy:
Nie, Zhe
Liu, Zheng-Xin
He, Xiang-Tao
Gong, Li-Hua
Tematy:
hyper-chaotic system
advanced encryption standard
discrete cosine transform
image encryption
image compression
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/174108.pdf  Link otwiera się w nowym oknie
Opis:
An image compression and encryption algorithm by combining the advanced encryption standard (AES) with the hyper-chaotic system is designed, in which Arnold map is employed to eliminate part of the block effect in the image compression process. The original image is compressed with the assistance of a discrete cosine transform and then its transform coefficients are encrypted with the AES algorithm. Besides, the hyper-chaotic system is adopted to introduce the nonlinear processfor image encryption. Numerical simulations and theoretical analyses demonstrate that the proposed image compression and encryption algorithm is of high security and good compression performance.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gaze-J2K: gaze-influenced image coding using eye trackers and JPEG 2000
Autorzy:
Nguyen, A.
Chandran, V.
Sridharan, S.
Tematy:
eye tracking
image compression
importance map
JPEG 2000
region of interest
Pokaż więcej
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Powiązania:
https://bibliotekanauki.pl/articles/309070.pdf  Link otwiera się w nowym oknie
Opis:
The use of visual content in applications of the digital computer has increased dramatically with the advent of the Internet and world wide web. Image coding standards such as JPEG 2000 have been developed to provide scalable and progressive compression of imagery. Advances in image and video analysis are also making human-computer interaction multi-modal rather than through the use of a keyboard or mouse. An eye tracker is an example input device that can be used by an application that displays visual content to adapt to the viewer. Many features are required of the format to facilitate this adaptation, and some are already part of image coding standards such as JPEG 2000. This paper presents a system incorporating the use of eye tracking and JPEG 2000, called Gaze-J2K, to allow a customised encoding of an image by using a user's gaze pattern. The gaze pattern is used to automatically determine and assign importance to fixated regions in an image, and subsequently constrain the encoding of the image to these regions.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The JPEG2000 standard for medical image applications
Autorzy:
Przelaskowski, A.
Tematy:
image compression
JPEG 2000
medical images
wavelet coding
medical information systems
Pokaż więcej
Wydawca:
Politechnika Gdańska
Powiązania:
https://bibliotekanauki.pl/articles/1965817.pdf  Link otwiera się w nowym oknie
Opis:
A new standard of still image compression is characterised in the context of medical applications. Wide spectrum of JPEG2000 features is analysed with respect to its application potential to improve the performance of modern medical services (i.e. telemedicine, PACS, radiology information systems, wireless personal/home health care systems). Image data security techniques, error resilience technologies, client-side interactive Region of Interest (ROI) transmission and decoding (e.g. for teleconsultation with very large radiography exams), and storage of multiple image data sets are considered in detail. Selected tests of coders realized according to parts I and II of JPEG2000 for different modality test images are presented to evaluate the compression efficacy of this standard. Exemplary results of encoding process optimisation by wavelet transform and subband decomposition selection and screen-shots of software interfaces designed for these tests are also presented.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza metod kompresji obrazów cyfrowych
Comparative analysis of methods of compression of digital images
Autorzy:
Moskalczuk, P.
Jóźwiak, P.
Kwiatkowski, Ł.
Tematy:
obraz cyfrowy
kompresja obrazu
WebM
MPEG-1
plik wideo
digital image
image compression
video file
Pokaż więcej
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Powiązania:
https://bibliotekanauki.pl/articles/324188.pdf  Link otwiera się w nowym oknie
Opis:
W artykule przedstawiono metody kompresji obrazów cyfrowych, wykazując różnice technologiczne w różnych formatach. Wykonano analizę kompresji pliku wideo do różnych formatów wskazując zalety najnowszych technologii w porównaniu ze starszymi rozwiązaniami.
In the paper a compression method of digital images showing the technology gap in different formats has been presented. An analysis of compressed video to various formats showing the adventages of the latest technologies in comparison with the older technologies has been presented, too.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The half-byte descriptor for image data units
Autorzy:
Czapla, Z.
Tematy:
półbajtowy format obrazu
obraz medyczny
kompresja obrazu
half-byte image format
medical images
image compression
Pokaż więcej
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Powiązania:
https://bibliotekanauki.pl/articles/333850.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents proposal for image data unit description using a half-byte format. It was implemented for medical images description. The introduced definitions express pixel values using differences between pixels and the introduced base value. This way the image recorded at half-byte format can be simply compressed by an appropriate compression, methods more effectively. The half-byte format is suitable for so called "natural" images with textures that are usually compressed with not satisfying results. For the given method illustration some example results were introduced.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An adaptive wavelet image compression system with TOPQS measure
Adaptacyjny system falkowej kompresji obrazów z miarą TOPQS
Autorzy:
Skublewska-Paszkowska, M.
Smołka, J.
Tematy:
falkowa kompresja obrazów
percepcyjna miara jakości
PQS
TOPQS
wavelet image compression
perceptual quality measure
Pokaż więcej
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Powiązania:
https://bibliotekanauki.pl/articles/408768.pdf  Link otwiera się w nowym oknie
Opis:
Image compression is present in many aspects of everyday life. Compression rate and quality improvement are the two most prominent directions of ongoing research. The adaptive system presented in this paper is able to compress input images using various wavelets. It controls consecutive compression stages in a way that allows one to obtain the final image with the least visual deformities. The system's functionality is based on the perceptual measure, TOPQS (Tuned by Observers Picture Quality Scale).
Zagadnienie kompresji obrazów jest obecne w wielu aspektach codziennego życia. Współczynnik kompresji i poprawa jakości są dwoma najbardziej znaczącymi kierunkami prowadzonych badań. Adaptacyjny system przedstawiony w artykule umożliwia kompresję obrazów z zastosowaniem rozmaitych transformat falkowych. Steruje kolejnymi etapami kompresji tak, aby uzyskać jak najmniej zniekształcony obraz wyjściowy. Funkcje systemu zostały oparte na percepcyjnej mierze TOPQS.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zone Selection in Image Compression Using Piecewise-Linear Transforms
Dobór strefy w kompresji obrazów z zastosowaniem transformat odcinkowo-liniowych
Autorzy:
Wiraszka, D.
Tematy:
kompresja obrazów
metody kompresji stratnej
kompresja strefowa
transformaty odcinkowo-liniowe
kompresja transformacyjna
image compression
lossy compression methods
zonal compression
piecewise linear transforms
transform compression
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/156485.pdf  Link otwiera się w nowym oknie
Opis:
Experimental results of retained zone shape selection in zonal transform compression of greyscale images with the use of piecewise-linear transforms have been presented in the paper. The Walsh and PWL transforms used in the initial stage of the compression algorithm have been described. The zonal compression method, based on retaining of the spectral coefficients belonging to the specified zone, has been presented. Besides the commonly used square zone, various shapes of the retained spectral zone have been considered. Computational results have been compared in terms of the Mean-Square Error (MSE) and the Peak Signal-to-Noise Ratio (PSNR) versus the Compression Ratio (CR). Visual inspection of the reconstructed images has been performed. Results of experiments with the use of the described method have been enclosed in the form of plots and images.
W artykule przedstawiono rezultaty badań nad wyborem kształtu zachowanej strefy w transformacyjnej kompresji strefowej obrazów ze skalą szarości z zastosowaniem transformat odcinkowo-liniowych. Opisano transformaty Walsha i PWL używane w początkowym stadium algorytmu kompresji. Przestawiono metodę kompresji strefowej, opartą o zachowywanie współczynników widmowych leżących wewnątrz wyspecyfikowanej strefy (rys. 2). Obok powszechnie stosowanej strefy kwadratowej rozważono różne kształty zachowanej strefy widmowej (rys. 3). Kształty stref dobrano na podstawie analizy obrazów widma współczynników stosowanych transformat (rys. 1). Przeanalizowano wpływ rozmiaru każdej z badanych stref na efektywność kompresji. W celu uniezależnienia analizy od parametrów wewnętrznych poszczególnych stref, określających bezpośrednio ich wymiary, wprowadzono obiektywny parametr, nazwany współczynnikiem kompresji (ang. Compression Ratio, CR), zależny wprost od liczby zer występujących w widmie zdegradowanym. Efektywność kompresji porównano w sensie błędu średniokwadratowego (ang. Mean-Square Error, MSE) oraz maksymalnego współczynnika sygnał-szum (ang. Peak Signal-to-Noise Ratio, PSNR) w funkcji współczynnika kompresji. Dokonano także wizualnej oceny jakości rekonstruowanych obrazów. Rezultaty badań z użyciem opisanej metody zamieszczono w postaci wykresów (rys. 4 - 7) i obrazów (rys. 8). Na podstawie przeprowadzonych badań wybrano strefy o najlepszym kształcie dla każdej z analizowanych transformat.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-color-image compression-encryption scheme in the quaternion discrete Fresnel domain
Autorzy:
Hu, Ze-Ting
Zeng, Ping-Ping
Ding, Hong-Xing
Gong, Li-Hua
Chen, Su-Hua
Tematy:
compressive sensing
quaternion discrete Fresnel transform
2D-LSCM chaotic system
image compression-encryption algorithm
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/58970442.pdf  Link otwiera się w nowym oknie
Opis:
A multiple color images compression-encryption scheme is designed with compressive sensing in the quaternion discrete Fresnel transform. To tackle multiple color images in a holistic manner, the discrete Fresnel transform is extended into the quaternion domain and the images are encrypted with the quaternion discrete Fresnel transform. In this scheme, the RGB color components of plaintext images are simultaneously compressed and encrypted in three mutually independent channels. Then the red, green and blue components are scrambled respectively by a chaos sequence generated by the 2D logistic-sine-coupling map. Each color component matrix is compressed with sparse representation and matrix measurement. Subsequently, the compressed matrices are integrated into the quaternion algebras and re-encrypted by the defined quaternion discrete Fresnel transform. The devised nonlinear cryptosystem originates from the asymmetric phase truncation operation. In decryption, the original color images are reconstructed by the gradient descent with a sparsification algorithm. The proposed multiple color images compression-encryption algorithm is feasible, effective, secure and robust.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A proposition of mobile fractal image decompression
Autorzy:
Nikiel, S.
Tematy:
fraktale
przetwarzanie obrazu
fraktalna kompresja obrazu
mobilne media
mapowanie tekstur
fractals
image processing
fractal image compression
mobile media
texture mapping
Pokaż więcej
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Powiązania:
https://bibliotekanauki.pl/articles/911258.pdf  Link otwiera się w nowym oknie
Opis:
Multimedia are becoming one of the most important elements of the user interface with regard to the acceptance of modern mobile devices. The multimodal content that is delivered and available for a wide range of mobile telephony terminals is indispensable to bind users to a system and its services. Currently available mobile devices are equipped with multimedia capabilities and decent processing power and storage area. The most crucial factors are then the bandwidth and costs of media transfer. This is particularly visible in mobile gaming, where textures represent the bulk of binary data to be acquired from the content provider. Image textures have traditionally added visual realism to computer graphics. The realism increases with the resolution of textures. This represents a challenge to the limited bandwidth of mobile-oriented systems. The challenge is even more obvious in mobile gaming, where single image depicts a collection of shots or animation cycles for sprites and a backdrop scenery. In order to increase the efficiency of image and image texture transfer, a fractal based compression scheme is proposed. The main idea is to use an asymmetric server-client architecture. The resource demanding compression process is performed on the server side while the client part decompresses highly packed image data. The method offers a very high compression ratio for pictures representing image textures for natural scenes. It aims to minimize the transmission bandwidth that should speed up the downloading process and minimize the cost and time of data transfer. The paper focuses on the implementation of fractal decompression schemes suitable for most mobile devices, and opens a discussion on fractal image models for limited resource applications.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low-power low-area near-lossless image compressor for wireless capsule endoscopy
Autorzy:
Turcza, Pawel
Duplaga, Mariusz
Opis:
The paper presents the concept of a low-power, low-area, near-lossless image compressor for resource-constrained devices such as wireless capsule endoscopy (WCE). The compressor directly processes the raw data from the Bayer Color Filter Array (CFA) imager to avoid the high cost of color interpolation. To improve the efficiency of the compressor in terms of energy consumption, silicon area and compression ratio, the main part of the compressor, i.e., the entropy encoder, uses the existing correlations between the color components of a captured CFA image. The proposed image compressor equires only 12.4% of the memory needed by other high-quality CFA compressors based on the JPEG-LS standard. Despite this significant reduction in memory size, the proposed image compressor outperforms other state-of-the-art coding schemes on capsule endoscopy images. At the same time, it offers only slightly lower performance on standard test images. The proposed image compressor has been implemented as an intellectual property (IP) core using two different low-cost CMOS processes. The design, implemented in UMC 180 nm CMOS process, requires a very low silicon area (534 × 426 μm2) and consumes very low energy (22μJ per a single 512 × 512 image frame). Even higher energy efficiency (12μJ per the same image frame) has the IP core implemented in the TSMC 130 nm CMOS process. Both of the selected technologies are low-cost and well-suited to implement a radio frequency transmitter and a low-power successive approximation register analog-to-digital converter in addition to the compressor to provide a cost-effective System on Chip for resource-constrained devices like WCE or wireless camera sensor network.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Strategies of covariance matrix calculation in the PCA method applied for three-dimensional data
Strategie tworzenia macierzy kowariancji w metodzie PCA dla danych trójwymiarowych
Autorzy:
Forczmański, P.
Tematy:
redukcja wymiarowości
analiza głównych składowych
macierz kowariancji
kompresja obrazu
dimensionality reduction
principal component analysis
covariance matrix
image compression
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/158248.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents a problem of reducing dimensionality of data structured in three-dimensional matrices, like true-color RGB digital images. In this paper we consider an application of Principal Component Analysis to one of the most typical image processing tasks, namely image compression. Unlike the cases reported in the literature [5,11,12] the compression being an application of three-dimensional PCA is performed on image blocks organized as three-dimensional structures (see Fig.1). In the first step, an image, which is stored as a three-dimensional matrix is decomposed into non-overlapping 3D blocks. Then each block is projected into lower-dimensional representation (1D or 2D) according to the chosen strategy: concatenation of rows, concatenation of columns, integration of rows, integration of columns [13] and concatenation of slices. Next, the blocks are centered (subtraction of mean value) and covariance matrices are being calculated. Finally, the eigenproblem is being solved on the covariance matrices giving a set of eigenvalues and eigenvectors, which are a base for creation of transformation matrices. Each block is then multiplied by respective transformation functions created from truncated eigenvectors matrices giving its reduced representation. The experimental part of the paper shows the comparison of strategies of calculating covariance matrices in the aspect of image reconstruction quality (evaluated by Peak Signal-to-Noise Ratio).
W niniejszym artykule przedstawiono problem redukcji wymiarowości danych zorganizowanych w trójwymiarowych macierzach za pomocą metody Analizy Głównych Składowych (PCA). W przeciwieństwie do znanych metod prezentowanych w literaturze [5,11,12] wybrane metody opisane w pracy zakładają wykonanie obliczeń dla danych zagregowanych, bez ich rozdzielania na kanały. W pierwszym kroku algorytmu obraz kolorowy (macierz trójwymiarowa) jest dekomponowany na niezależne sub-bloki (3D). Następnie każdy z bloków jest poddawany projekcji 1D lub 2D zgodnie z przyjętą strategią: poprzez konkatenację wierszy, konkatenację kolumn, integrację wierszy, integracje kolumn lub konkatenację warstw. W kolejnym kroku są one centrowane i obliczane są odpowiednie macierze kowariancji. Następnie obliczany jest ich rozkład, który służy do stworzenia macierzy transformacji 3D PCA. Za ich pomocą przeprowadzana jest redukcja wymiarowości danych obrazowych. W przypadku omawianym w niniejszej pracy kompresji poddany jest obraz RGB i oceniana jest jakość rekonstrukcji (PSNR) jako funkcja liczby pozostawionych współczynników przekształcenia.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of video detectors working with lossy compressed video streams
Autorzy:
Pamuła, W.
Tematy:
czujnik wideo
sekwencja obrazów
stratna kompresja obrazów
parametry ruchu drogowego
video detector
image sequence
lossy image compression
road traffic parameters
Pokaż więcej
Wydawca:
Polskie Stowarzyszenie Telematyki Transportu
Powiązania:
https://bibliotekanauki.pl/articles/393365.pdf  Link otwiera się w nowym oknie
Opis:
Complex traffic control systems are equipped with a range of cameras for traffic surveillance, road traffic measurements. On many sites the different cameras cover the same observation areas but provide different quality streams to the system, usually compressed for surveillance and raw for vehicle detection. Elimination of duplicate cameras especially high quality devices is desired for enhancing the performance of systems. Vehicle detectors based on image processing are sensitive to the quality of input video streams. The paper presents results from tests of using lossy data compression for delivering video streams to vehicle detectors for traffic control. The limit of data loss is determined for assuring correct vehicle detection. The recommendations can be used for optimising traffic vision systems.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of raster file optimisation on the performance of a map application
Autorzy:
Król, Karol
Zdonek, Dariusz
Tematy:
image compression
web services
geoinformatics
performance indicators
visual quality
kompresja obrazu
usługi internetowe
geoinformatyka
wskaźniki efektywności
jakość wizualna
Pokaż więcej
Wydawca:
Uniwersytet Rolniczy im. Hugona Kołłątaja w Krakowie
Powiązania:
https://bibliotekanauki.pl/articles/100378.pdf  Link otwiera się w nowym oknie
Opis:
Interactive data visualisations are popular and come in different forms, from static raster files to dynamic and complex proposals. The usability of the applications can be increased through the improvement of their technical attributes such as a reduced number of external components or image file compression. The objective of the paper is to analyse the correlation between raster compression and the performance of a map application. The research involved an application created specifically for this purpose. Raster compression and performance were measured using selected online tools. Raster compression has been demonstrated to enhance map application performance, although not all performance indicators improved.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies