Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "leachate" wg kryterium: Temat


Tytuł:
One step purification of impurities in the leachate of weathered crust elution-deposited rare earth ores
Autorzy:
Zhou, F.
Feng, J.
Wang, Z.
Xu, Y.
Zhang, Z.
Chi, R.
Tematy:
leachate
weathered crust
rare earth ore
leachate purification
precipitation
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/110333.pdf  Link otwiera się w nowym oknie
Opis:
It is necessary to control and reduce the high content of Al3+, Cu2+ and Pb2+ ions in the leachate of weathered crust elution-deposited rare earth ore to facilitate the rare earth recovery and the quality of rare earth products. Neither NH4HCO3 nor Na2S are suitable for removal of all impurity ions and meanwhile maintain high rare earth recovery. Conventionally, NH4HCO3 is firstly adopted to remove Al3+, and then Cu2+ and Pb2+ are removed by using Na2S. This two steps purification process is quite long and results in lots of complication in operation. In this paper, a one-step purification by using the compound of NH4HCO3 and Na2S was proposed to remove Al3+, Cu2+ and Pb2+. The results showed that after purification 89% Cu, 92% Pb and 74% Al were removed from the leachate solution by using 0.1 M compound of NH4HCO3/Na2S, while maintaining 89% rare earth. The optimal purification parameters were: volume ratio of NH4HCO3 to Na2S of 9:1, volume ratio of compound to leachate of 0.05:1, precipitation time of 30 min.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka składu oraz ilości odcieków ze składowisk odpadów komunalnych – praca przeglądowa
Characteristics of the composition and quantity of leachate from municipal landfills - a review
Autorzy:
Długosz, J.
Tematy:
leachate
leachate composition
water balance
odcieki
skład odcieków
bilans wodny
Pokaż więcej
Wydawca:
Politechnika Śląska
Powiązania:
https://bibliotekanauki.pl/articles/357591.pdf  Link otwiera się w nowym oknie
Opis:
Paper is a review of the literature concerning the characteristics of the composition and quantity of leachate generated in the operation of the municipal waste landfill. In article characterizes factors influencing the composition of the leachate. This paper also presents an overview of the formation of leachate, and water balance diagram of the landfill.
Praca jest przeglądem literatury na temat charakterystyki składu oraz ilości wytwarzanych odcieków w trakcie eksploatacji składowiska odpadów komunalnych. W artykule scharakteryzowano czynniki wpływające na skład odcieków. Przedstawiono również ogólny zarys tworzenia się odcieków i schemat bilansu wodnego składowiska.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Leachates Recirculation Impact on the Stabilization of the Solid Wastes – A Review
Autorzy:
Hussein, Omar Amer
Ibrahim, Jathwa Abd-Alkareem
Tematy:
solid waste management
leachate recirculation
landfill leachate
solid waste stabilisation
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/24201719.pdf  Link otwiera się w nowym oknie
Opis:
In most countries, controlled landfills are currently the most common disposal method for municipal solid wastes (MSWs). Despite many benefits, the generation of heavily contaminated leachate with substantial differences in both chemical composition and flow rate represents a major drawback. The realization of this has compelled authorities to adopt ever more stringent establishment of pollution control requirements. Landfill leachate is a serious problem in the treatments of municipal solid wastes using landfills methods. This leachate is usually heavily contaminated, but little attention is paid to its treatment. Optimal treatment of leachates to completely decrease the harmful environmental impacts is today’s challenge. However, the complex composition of leachates makes it challenging to formulate general recommendations. Leachate variability, particularly over time and within sites, suggests that the most appropriate treatments are adaptable, universal, and simple. Landfill leachate is characterized by high biological and chemical oxygen demand and is usually composed of undesirable ingredients such as inorganic and organic pollutants. Landfill leachate varies with landfill age and content, decomposition methods, hydrological and climate conditions. Recirculation of leachate does not affect alterations in the degree of bio-degradability of the waste. During landfill operations, recirculation of leachate is often applied to help stabilize landfill degradation. Leachate recirculation is widely used in practical engineering, and recirculation using vertical wells is one of the more effective methods.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie odwróconej osmozy w procesie oczyszczania odcieków
Treatment of landfill leachate with reverse osmosis
Autorzy:
Tałałaj, I.
Tematy:
jakość odcieków
odwrócona osmoza
oczyszczanie odcieków
leachate quality
reverse osmosis
leachate treatment
Pokaż więcej
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Powiązania:
https://bibliotekanauki.pl/articles/908533.pdf  Link otwiera się w nowym oknie
Opis:
Składowanie odpadów jest wciąż najbardziej powszechną metodą ich unieszkodliwiania. Szacuje się, że na świecie postępuje się tak z 95% wytworzonych odpadów. Podczas składowania w bryle odpadów zachodzi szereg procesów fizyczno- chemicznych oraz biologicznych. Rozkład materii organicznej w połączeniu z infiltracją wód opadowych prowadzi do wymywania z niej silnie zanieczyszczonych wód, zwanych odciekami.2 Skład odcieków i stężenie w nich zanieczyszczeń zależy głównie od rodzaju składowanych odpadów, sposobu eksploatacji składowiska oraz czasu składowania.
One of landfill’s product is leachate, which is highly and complexly polluted wastewater. Landfill leachate, especially old one is very difficult to treat using conventional biological processes. One of the methods to be used in the treatment of such leachate is reverse osmosis. This paper compares the effectiveness of reverse osmosis in removing BOD5, COD, NH3-N and selected heavy metals. Efficiency of leachate treatment by one-and two-stage reverse osmosis system was characterized. The effects of the membrane type on the purification are also described. The influence of the waste quality on leachate treatment efficiency and the risks associated with the use of reverse osmosis in the leachate treatment were also described.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of Leachate Quality at a Selected Municipal Landfill Site in Podlasie, Poland
Autorzy:
Tałałaj, I. A.
Biedka, P.
Walery, M. J.
Leszczyński, J.
Tematy:
leachate
landfill
monitoring
pollution
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/125226.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents an evaluation of leachate monitoring data as well as investigation of temporal and seasonal variability of leachate quality. The analysis includes 27 sampling carried out at selected municipal landfill during 7-year observation period. In leachate samples, concentration of Pb, Cu, Zn, Cr, Hg, Cd, Total Organic Carbon (TOC), Polycyclic Aromatic Hydrocarbons (PAH) and value of pH and electro-conductivity (EC) were determined. Estimation of landfill leachate demonstrated a declining trend in EC, TOC and Zn concentration with time. Concentration of Pb, Hg, Cr, Cd and PAH remained relatively constant with respect to the sampling time, however, the value of pH showed a growing trend due to the decrease of the concentration of the partially ionized free volatile fatty acids. Average concentration of heavy metals in leachate were observed in trace quantities (<1.0 mg·dm-3). There were no statistically significant seasonal variations in concentration of the analyzed parameters, however, the highest concentration of EC, TOC and PAH were observed in summer. The negative correlation of pH with Pb, Cu, Zn, Cr, Hg, Cd indicated a strong connection of leachate’s pH with heavy metals concentration. A cluster analysis allowed to specify two groups of variables: cluster I with TOC as an indicator of organic pollution in leachate and claster II with the rest of parameters. Further systematic monitoring is necessary, but its scope, according to the author, should be redefined.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Landfill Leachate on Groundwater Quality – A Comparison Between Three Different Landfills in Morocco
Autorzy:
Benaddi, Rabia
Ferkan, Yousra
Bouriqi, Abdelillah
Ouazzani, Naaila
Tematy:
landfill
leachate
pollution
groundwater
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/2202212.pdf  Link otwiera się w nowym oknie
Opis:
In this work, physicochemical and bacteriological analyses of leachate collected from three different landfills in the Marrakech region in Morocco were carried out. The results showed that the leachate is highly loaded with organic matter, chemical and bacteriological elements and some heavy metals, this load depends of the nature of landfill (rural or urban) and also of its age (young or old), the values of the parameters exceed the limit values for discharge into the natural medium. Physicochemical and bacteriological analyses of groundwater from wells downstream of these landfills were also carried out; The results showed that they had medium to poor quality according to the type of landfill. This is due to the presence of organic matter, total coliforms, total phosphorus and total nitrogen in many studied wells.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of removal of heavy metals from municipal landfill leachate
Efektywnosc usuwania metali ciezkich z odciekow ze skladowisk odpadow komunalnych
Autorzy:
Koc-Jurczyk, J
Jurczyk, L.
Tematy:
heavy metal
removal efficiency
municipal landfill
leachate
landfill leachate
Fenton's reaction
activated sludge
Pokaż więcej
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie / Polskie Towarzystwo Magnezologiczne im. Prof. Juliana Aleksandrowicza
Powiązania:
https://bibliotekanauki.pl/articles/14425.pdf  Link otwiera się w nowym oknie
Opis:
The aim of this study was to determine the rate of removal of heavy metals depending on a treatment method applied to leachate from a municipal waste landfill. After the biological treatment, concentrations of Cu, Zn and Ni were observed to have increased. Application of the reagent Fenton caused further growth in Cu, Zn, and also Pb concentrations. The highest concentrations of Cu, Zn and Ni were observed when the Fe2+: H2O2 ratio in Fenton was 1:3. The lowest concentrations of these heavy metals were observed at a 1:5 ratio of Fe2+ : H2O2. The concentration lead, for example, was over 30-fold higher than in raw leachate. There was not correlation between the COD values in raw leachate or in biologically or chemically processed leachate and the concentrations of the analysed metals.
W pracy badano wpływ oczyszczania odcieków ze składowisk odpadów komunalnych na stężenie występujących w nich metali ciężkich. Oczyszczanie biologiczne spowodowało wzrost stężenia Cu, Zn i Ni. Po zastosowaniu odczynnika Fentona stwierdzono dalszy wzrost stężenia Cu, Zn, a także Pb. Proporcja Fe2+: H2O2 wynosząca 1:3 okazała się niekorzystna w przypadku Cu, Zn i Ni, ponieważ ich stężenie było w tych warunkach najwyższe. W przypadku proporcji Fe2+: H2O2 wynoszącej 1:5 zaobserwowano najniższe stężenia Cu, Zn i Ni, podczas gdy stężenie Pb było ponad 30-to krotnie wyższe niż w odciekach surowych. Nie stwierdzono korelacji między wartością ChZT w odciekach surowych oraz oczyszczonych biologicznie i chemicznie a stężeniem analizowanych metali ciężkich.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational problems of constructed wetland for landfill leachate treatment: case study
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Tematy:
treatment wetland
landfill leachate
clogging
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/125011.pdf  Link otwiera się w nowym oknie
Opis:
The present paper discusses the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and the evaluation of a wetland system designed for treatment of the leachate. The research has been conducted during a 5-year period. The constructed wetland for leachate treatment was built in 2001; it consists of 2 horizontal subsurface flow reed beds, working in parallel. In the period 2005–2006 it underwent modernization due to unsatisfactory treatment results caused by bed clogging. After the modernization the treatment effectiveness is satisfactory. The effluent from bed I met Polish outflow standards, while in the effluent from bed II COD, total N and TSS exceeded the required concentrations. In spite of this, pretreatment of leachate (iron removal) should be quickly introduced to protect the system against the reoccurrence of clogging problems.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ relacji Fe:H2O2 na skład odcieków składowiskowych po oczyszczaniu metodą Fentona
The impact of relation Fe:H2O2 on the composition of leachate after treatment Fenton’s method
Autorzy:
Muszyńska, J.
Gawdzik, J.
Sikorski, M.
Tematy:
odcieki składowiskowe
AOP
proces Fentona
remediacja odcieków
landfill leachate
Fenton process
remediation of leachate
Pokaż więcej
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/126886.pdf  Link otwiera się w nowym oknie
Opis:
W wyniku funkcjonowania składowisk odpadów powstają odcieki, które są odzwierciedleniem zmian zachodzących w czaszy składowiska. Na początku funkcjonowania składowiska powstają odcieki zawierające głównie produkty podatne na biodegradację, wraz z upływem czasu rośnie ilość związków trudno biodegradowalnych. Ze względu na zmienność składu i ilości powstających odcieków ich oczyszczanie jest trudnym zadaniem technologicznym i wymaga szeregu badań. Do oczyszczania odcieków stosowane są zarówno metody biologiczne, fizyczno-chemiczne, jak i metody pogłębionego utleniania, np. metoda Fentona. W artykule przedstawiono problematykę dotyczącą wpływu relacji Fe:H2O2 w procesie Fentona na skład oczyszczonych odcieków i redukcję wybranych zanieczyszczeń. Omówiono parametry fizyczno-chemiczne odcieków surowych oraz po procesie oczyszczania metodą Fentona. Celem badań, oprócz wykonania analiz chemicznych, było również określenie zależności pomiędzy stosunkiem Fe:H2O2 a efektem obniżenia wartości wybranych wskaźników zanieczyszczeń. Wyniki analiz odniesiono do dopuszczalnych zakresów stężeń wybranych substancji zamieszczonych w rozporządzeniach krajowych. Proces Fentona prowadzono przy stosunku wagowym Fe:H2O2 jak 1:3, 1:5, 1:7, 1:10 przy dawce Fe co 50 g/m3 w zakresie od 50-400 g/m3. W odciekach surowych i oczyszczonych analizowano zawartość takich parametrów, jak ChZT, OWO, UV254, barwa. Na podstawie wyników badań wybrano optymalną relację Fe:H2O2. Wyjaśniono możliwe przyczyny niskiej skuteczności wysokich dawek Fe przy relacji Fe/H2O2 1:10.
As a result of the storage of waste, generation of leachate reflect changes in the canopy landfill. At the beginning of landfill operation, the landfill leachate arise mainly products biodegradable, over time, increasing the number of non-biodegradable compounds. Due to the variability of the composition and quantity of leachate generated their cleaning is difficult and requires a number of technological research. For leachate treatment they are used both methods of biological and physico-chemical methods such as advanced oxidation e.g. Fenton’s method. The article presents the problem of the impact of the relationship between Fe/H2O2 ratio of process Fenton on the composition of treated effluent and a reduction of selected pollutants. The physico-chemical parameters of raw leachate and after the process of purification by Fenton have been discussed. The aim of the research, in addition to performing chemical analyses, was also to determine the relationship between the ratio Fe:H2O2 and the reduction of selected pollutants. The results of analyses related to the limit values given in national regulations. Fenton process was carried out at a weight of Fe: H2O2 ratio: 1: 3, 1: 5, 1: 7, 1:10 Fe at a dose of 50 g/m3 in the range of 50-400 g/m3. The leachate raw and analysed the contents of parameters such as COD, TOC, UV254, colour. Based on the results of research we selected the optimal ratio of Fe:H2O2. The possible causes of low effectiveness of high doses of Fe for the ratio Fe:H2O2 1:10 was explained.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies