Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "lenses" wg kryterium: Temat


Tytuł:
Interaction of silicone hydrogel contact lenses with lipids – a chronological review
Autorzy:
Suliński, Tomasz
Pniewski, Jacek
Tematy:
contact lens deposits
contact lens discomfort
contact lenses
silicone hydrogel contact lenses
Pokaż więcej
Wydawca:
Medical Education
Powiązania:
https://bibliotekanauki.pl/articles/1928016.pdf  Link otwiera się w nowym oknie
Opis:
Silicone hydrogel (SiHy) contact lenses are a common form of correction of refractive errors prescribed by eye care professionals around the world. SiHy lenses perform in a complex environment, which is the surface of the eye and the tear film. Therefore, they are exposed to various factors, such as lipid deposits. The aims of this paper are to review available scientific reports on the study of SiHy lens interactions with lipids and search for further research objectives. A total of 57 publications were identified and reviewed, from 2003 to 2020. In general, SiHy lenses are more likely to accumulate lipid deposits than traditional hydrogel lenses, although there are significant differences between SiHy lens materials that may result from different methods used in the studies. The review includes studies on various aspects of interactions between lenses and lipids, such as those concerning the effectiveness of lipids removal from lenses by care solutions. The conclusion points out future research directions, such as measurements of lipid diffusion in SiHy lens' matrices.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Building a new software of electromagnetic lenses (CADTEL)
Autorzy:
Hasan, H.S.
Tematy:
Electron lenses
Objective and projector properties
Lenses aberrations
Electron optics
Charged particle optics
Software and simulation in electron lenses
Pokaż więcej
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Powiązania:
https://bibliotekanauki.pl/articles/411585.pdf  Link otwiera się w nowym oknie
Opis:
The Computer Aided designing Tools for Electromagnetic Lenses (CADTEL) is a new software as application package of programs concept to aid both users and professionals in symmetric and asymmetric electromagnetic lenses with single, double, and multipole piece in electron microscope of electron optics field. The CADTEL software has been designed to run on several computer platforms and includes two types of design procedure. The first one named, analysis procedure (which is based on trial and error) where consist of three sorts called; H1 programs for magnetic scalar potential by solving Laplace's equation [1, 2], H2 and H3 programs for magnetic vector potential by solving Poisson's equation [3, 4] in linear and non linear media respectively. While the second part, named H4 programs for the synthesis procedure (inverse design). The previous types differ by the obtaining the magnetic flux density, and poles shape, while it is analog by compute and plot the lens properties which are operating at zero, low, high, and infinite magnification conditions (operation modes). CADTEL software consist of computational and plot steps of magnetic field, equipotential surfaces, flux lines, objective and projector properties, and poles shape for proposed lens design which are appear in auto visual interfaces, that are coded in visual basic language [5].
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Patient with cataract - observations after 2 years of the pandemic and future prospects
Pacjent z zaćmą – obserwacje po 2 latach pandemii i perspektywy na przyszłość
Autorzy:
Misiuk-Hojło, Marta
Dołowiec-Kwapisz, Anna
Tematy:
cataract
pandemic
intraocular lenses
EDOF
multifocal lenses
zaćma
pandemia
soczewki wewnątrzgałkowe
soczewki wieloogniskowe
Pokaż więcej
Wydawca:
Medical Education
Powiązania:
https://bibliotekanauki.pl/articles/2159020.pdf  Link otwiera się w nowym oknie
Opis:
Cataract is a disease in which the natural lens becomes completely or partially cloudy. During the pandemic, there was a significant decrease in the number of cataract surgeries performed compared to previous years, due to fear of the disease and the safety of the procedures performed. Cataract surgery should be performed in patients whose visual acuity deterioration has an impact on the performance of life or work activities. Due to the pandemic, some patients report to a more advanced stage of cataract, which leads to a reduction in their quality of life. Such surgery can be associated with a higher risk of surgical complications and longer recovery time. The development of new intraocular lens technologies, increased life expectancy, as well as changing lifestyles and increased activity of the elderly contribute to the increasing choice of premium intraocular lenses by patients. These lenses enable patients to achieve satis-factory uncorrected visual acuity not only for distance, but also for near and intermediate distances.
Zaćma to choroba polegająca na całkowitym lub częściowym zmętnieniu naturalnej soczewki. W okresie pandemii obserwowano znaczny spadek liczby wykonywanych operacji usunięcia zaćmy w stosunku do lat wcześniejszych, wynikający z obawy przed zachorowaniem i o bezpieczeństwo wykonywanych zabiegów. Usunięcie zaćmy powinno być przeprowadzone u pacjentów, u których pogorszenie ostrości widzenia ma wpływ na wykonywanie czynności życiowych lub zawodowych. Okres pandemii spowodował, że część pacjentów zgłasza się w bardziej zaawansowanym stadium zaćmy, co prowadzi do obniżenia komfortu ich życia. Taki zabieg obarczony jest większym ryzykiem powikłań operacyjnych i dłuższą rekonwalescencją. Rozwój nowych technologii soczewek wewnątrzgałkowych, wydłużenie średniej długości życia, a także zmiana stylu życia oraz większa aktywność zawodowa osób w starszym wieku przyczyniają się do coraz częstszego wyboru przez pacjentów soczewek wewnątrzgałkowych z grupy premium. Soczewki te pozwalają osiągnąć satysfakcjonującą nieskorygowaną ostrość widzenia nie tylko do dali, ale także do bliży oraz odległości pośredniej.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of dehydration and water states in new and worn soft contact lens materials
Autorzy:
Krysztofiak, K.
Szyczewski, A.
Tematy:
contact lenses
dehydration
hydrogel
silicone hydrogel
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/173833.pdf  Link otwiera się w nowym oknie
Opis:
The purpose of this study was to examine the in vitro dehydration characteristics of new and worn conventional and silicone-hydrogel contact lenses. Four contact lens materials were investigated: three conventional hydrogels (etafilcon, nelfilcon, omafilcon) and one silicone-hydrogel (narafilcon). Gravimetric data were obtained with analytical balance with 1 min intervals. Quantitative parameters of water content and dehydration rate were calculated allowing quantitative description of dehydration process. Differential scanning calorimetry was used to monitor changes in water states in samples studied. As expected, dehydration behavior of each material is different in terms of mean dehydration rate values and phases of dehydration. Gravimetric data allowed us to distinguish three phases of dehydration. Interestingly, the effect of the osmolality of storing solutions on dehydration was found – lenses stored in hyperosmotic solutions needed more time to achieve equilibrium with the environment. Effect of wearing on dehydration patterns and water properties was confirmed. In worn samples, a decrease in water content was observed. Additionally, there was a change in water structure after 6 h of wearing in all lenses studied. This behavior may be ascribed to tear film components deposition and changes in surface wettability that appear during wearing.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ hialuronianu na dehydratację i strukturę wody w hydrożelowych soczewkach kontaktowych
Effect of hyaluronan on dehydration and water properties of contact lens hydrogels
Autorzy:
Krzysztofiak, K.
Rajchel, D.
Szyczewski, A.
Tematy:
soczewki kontaktowe
hydrożel
hialuronian
contact lenses
hydrogel
hyaluronan
Pokaż więcej
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Powiązania:
https://bibliotekanauki.pl/articles/285220.pdf  Link otwiera się w nowym oknie
Opis:
Jednym z potencjalnych sposobów ograniczenia niepożądanej z punktu widzenia pacjenta utraty wody z soczewek kontaktowych są krople nawilżające oparte na roztworach hialuronianu sodu (HA). DSC oraz grawimetria zostały wykorzystane w celu zbadania ich wpływu na strukturę wody i dehydratację hydrożelowych soczewek kontaktowych Acuvue Moist i Proclear 1-Day. Jak wskazują wyniki, materiały mogą różnie reagować na aplikację kropli nawilżających o różnych stężeniach HA poprzez zmianę rozkładu wody w polimerze. Podobnie dynamika dehydratacji ulega zmianom w zależności od badanego materiału. Nie ulega jednak wątpliwości, że stosowanie roztworów HA zwiększa uwodnienie obydwu badanych materiałów, co może korzystnie wpływać na zwilżalność ich powierzchni, redukując ewentualny dyskomfort związany z dehydratacją soczewki podczas noszenia.
One of the potential way of restricting dehydration that is undesirable from the patient point of view is to use hydrating eyedrops based on hyaluronan sodium (HA) solutions. DSC and gravimetry were used in order to investigate their influence on states of water and dehydration of hydrogel contact lenses Acuvue Moist and Proclear 1-Day. As our results indicate, both materials may respond differently to application of rewetting drops of different HA concentrations by change in water structure. Similarly, dynamics of dehydration is changing according to the material. Nevertheless, the use of HA solutions enhance water content of both materials studied, which may be beneficial for lens surface wettability, reducing possible discomfort during normal lens wear.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Contact lenses and dry eye syndrome: can they be reconciled?
Autorzy:
Waszczykowska, Arleta
Tematy:
dry eye disease
contact lenses
contact lens discomfort
Pokaż więcej
Wydawca:
Medical Education
Powiązania:
https://bibliotekanauki.pl/articles/51789558.pdf  Link otwiera się w nowym oknie
Opis:
The function of the tear film is to moisturize, lubricate, nourish, and protect the delicate surfaces of the cornea and conjunctival epithelium covering the eyeball and eyelids. A healthy tear film is crucial for shaping and maintaining a smooth refractive surface of the cornea, ensuring proper optical function of the eye by eliminating small irregularities in the epithelium. Contact lens wearers often experience various discomforts related to wearing lenses, known as contact lens discomfort (CLD), which can lead to discontinuation of lens wear. CLD is frequently associated with dry eye disease, caused by tear film disorders resulting from incorrect composition, reduced production, or excessive evaporation of tears from the ocular surface. Contact lens wear can diminish corneal sensitivity and lead to a reflex blockade of sensation, causing a deficiency in the aqueous layer of the tear film. Additionally, wearing contact lenses may increase tear evaporation due to reduced blinking frequency and incomplete eyelid closure during blinking. This paper discusses therapeutic approaches and modifications in lens fitting aimed at maintaining a healthy ocular surface and improving comfort for contact lens wearers.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Early Cosmetic Contact Lenses for Hollywood Film Actors
Autorzy:
Heitz, Robert F.
Wydawca:
Jean-Paul Wayenborgh, Asuncion, Paraguay
Opis:
The first use of contact lenses to alter the look of actors in Hollywood goes back to the year 1939. That year, the optometrist Reuben Greenspoon from Berverley Hills had presented a demonstration of ocular molding on the living eye for educational films. Later on he adapted colored contact lenses to the actor Henry Hull for the movie Miracles of Sales and also to the actor Walter Hampton for North West Mounted Police. The next year Greenspoon modified on that manner the aspect of the eyes of Orson Welles and of Joe Cotton for the famous film Citizen Kane. In 1945, Greenspoon modifies the eyes of actor Herbert Marshal into blind eyes in The Enchanted Cottage. Reuben Greenspoon became the expert and the reference for the adaptation of cosmetical contact lenses for the entertainment industry of Hollywood.
Andrzej Grzybowski
Dostawca treści:
Repozytorium Centrum Otwartej Nauki
Artykuł
Tytuł:
Evaluation of error in the performance of power corrected ophthalmic lenses
Autorzy:
Trujillo-Schiaffino, G
Salas-Peimbert, D P
Anguiano-Morales, M
Malacara-Doblado, D
Vega-Pineda, J
Tematy:
ophthalmic lenses
refractive correction error
Hartmann test
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/173334.pdf  Link otwiera się w nowym oknie
Opis:
In this work, we describe a new method for assessing the refractive correction error in power corrected ophthalmic lenses. The ideal power distribution map corresponding to the lens design to be measured is initially obtained. Then, using some known techniques, the real power distribution map of the lens under test is obtained. Finally, the difference between the two distributions is computed, obtaining a distribution map of the refractive correction error of the lens under analysis. In the paper, we describe the implementation of the proposed method using the Hartmann test to analyze a corrected power ophthalmic lens. The technique is analyzed, and its effects on measurement resolution discussed. This method can be useful to verify the designing errors in the lab or to verify manufacturing errors of ophthalmic lenses during mass production.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical Properties of Intraocular Implants Coated with Silver Nanoparticles
Autorzy:
Jeż, Kinga
Gacek, Marcin
Nabiałek, Marcin
Tóth, László
Pike-Biegunski, M.
Tematy:
UV-Vis spectroscopy
intraocular lenses
silver nanoparticles
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/2049713.pdf  Link otwiera się w nowym oknie
Opis:
Prolonged exposure to UV radiation, and ever-increasing life expectancy, mean that an increasing proportion of the population suffers from clouding of the intraocular lens. Nowadays, the performance of intraocular implantation procedures is commonplace. Unfortunately, with the increasing number of operations, the number of postoperative complications is also increasing. One way to avoid complications may be to use an intraocular implant that has been immersed in a solution containing silver nanoparticles. As part of the study, four selected intraocular implants – that are available on the ophthalmic market – were tested. In order to investigate the effect of silver particles on the optical properties of the implants, tests were carried out using a UV-VIS spectrophotometer. Two series of implants were tested: before and after immersion in a silver solution. The implants were immersed for a period of 7 days. It was found that the presence of silver particles does not have a negative impact on the translucency of the implants.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie jakości soczewek z powłokami antyrefleksyjnymi na podstawie odporności na ścieranie oraz transmisji światła w zakresie światła widzialnego
Comparison of the quality of lens with anti-reflex coating on based of abrasion resistance and light transmission in the visible
Autorzy:
Jeż, B.
Nabiałek, M.
Tematy:
soczewki
powłoki antyrefleksyjne
transmisja światła
odporność soczewek na ścieranie
lenses
anti-reflective coating
light transmission
resistance to abrasion lenses
Pokaż więcej
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Inżynierii Materiałów Polimerowych i Barwników
Powiązania:
https://bibliotekanauki.pl/articles/278370.pdf  Link otwiera się w nowym oknie
Opis:
W niniejszym opracowaniu przedstawiono wyniki badań dotyczących jakości organicznych soczewek okularowych z powłokami antyrefleksyjnymi dostępnych na rynku oftalmicznym. Za kryteria jakościowe uznano dwie bardzo istotne cechy soczewek: transmisję światła oraz odporność soczewek na ścieranie. Badania transmisji światła wykonano za pomocą spektrofotometru natomiast badania odporności na ścieranie przeprowadzono oscylacyjnym testerem ścieralności. Uzyskane wyniki transmisji światła odniesiono do nieuszlachetnionej soczewki natomiast wyniki pomiaru odporności na ścieranie odniesiono do soczewki mineralnej. Uzyskane rezultaty pokazują znaczną różnicę w poziomie jakości soczewek posiadających podobne powłoki, nie stwierdzono szczególnego wpływu powłok hydro i oleofobowych na odporność na ścieranie oraz transmisję światła.
This paper presents the results of research the quality of organic spectacle lenses with anti-reflex coatings available on ophthalmic commercially. For qualitative criteria were considered two very important characteristics of the lenses: light transmission and resistance to abrasion lenses. Research of light transmission was performed using a spectrophotometer while research of abrasion resistance was carried out oscillating abrasion tester. The results was related to the light transmission of the lens not ennobled and the results of measurement of abrasion resistance was related to lens mineral. The results show a significant difference in the level of quality lenses having similar coatings, there was no particular impact hydro and oleophobic coating for abrasion resistance and light transmission.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies