Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "microbeam" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Thermoelastic problem of an axially moving microbeam subjected to an external transverse excitation
Autorzy:
Abouelregal, A. E.
Zenkour, A. M.
Tematy:
thermoelasticity
microbeam
sinusoidal pulse heating
axially moving
transverse excitation
Pokaż więcej
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Powiązania:
https://bibliotekanauki.pl/articles/279181.pdf  Link otwiera się w nowym oknie
Opis:
In this study, the problem of an axially moving microbeam subjected to sinusoidal pulse heating and an external transverse excitation is solved. The generalized thermoelasticity theory with one relaxation time is used to solve this problem. An analytical technique based on the Laplace transform is used to calculate the vibration of deflection and the temperature. The inverse of Laplace transforms are computed numerically using Fourier expansion techniques. The effects of the pulse-width of thermal vibration, moving speed and the transverse excitation are studied and discussed on the lateral vibration, temperature, displacement and bending moment of the beam.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System do pomiaru ugięcia belek krzemowych stosowanych w mikroczujnikach
System for the silicon beam deflection measurements in microsensor
Autorzy:
Gołębiowski, J.
Tematy:
mikro-belki krzemowe
przetworniki optoelektroniczne
silicon microbeam
optoelectronic transducers
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/151634.pdf  Link otwiera się w nowym oknie
Opis:
W pracy przedstawiono system do pomiaru ugięcia mikrobelki krzemowej. System składa się z części optycznej oraz sterownika i komputera. Omówiono zasadę działania systemu oraz przeanalizowano dobór parametrów układu do pomiaru niewielkich ugięć rzędu mikrometrów. Przedstawiono oprogramowanie pozwalające na wizualizację aktualnego położenia belki. Zamieszczono wyniki badań oraz określono przydatność systemu do pomiaru niewielkich ugięć.
The system for the measurement of silicon microbeam deflection is presented. It consists of an optical part, a controller and a computer. The principle of the system in operation and the parameter selection for the measurements of the small (micrometers) deflections are described and analysed. The program which allows visualizing the current beam location is also presented. The results show the system usefulness for the micrometer deflection measurements.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Forced vibrations of a thermoelastic double porous microbeam subjected to a moving load
Autorzy:
Kumar, Rajneesh
Vohra, Richa
Tematy:
double porosity
thermoelasticity
Lord-Shulman theory
microbeam
moving load
Pokaż więcej
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Powiązania:
https://bibliotekanauki.pl/articles/281208.pdf  Link otwiera się w nowym oknie
Opis:
The present paper deals with forced vibrations of a homogeneous, isotropic thermoelastic double porous microbeam subjected to moving load, in context of Lord-Shulman theory of thermoelasticity with one relaxation time. The Laplace transform has been applied to obtain expressions for the axial displacement, lateral deflection, volume fraction field and temperature distribution. A numerical inversion technique has been used to recover the resulting quantities in the physical domain. Effects of velocity and time parameters are shown graphically by plotting axial displacement, lateral deflection, volume fraction field and temperature distribution against distance. Some particular cases are also deduced.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Free vibration of a hyper-elastic microbeam using a new “augmented Biderman model”
Autorzy:
Karami Mohammadi, Ardeshir
Danaee Barforooshi, Saeed
Tematy:
nonlinear vibration
hyper-elastic microbeam
augmented Biderman model
modified couple stress theory
Pokaż więcej
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Powiązania:
https://bibliotekanauki.pl/articles/949138.pdf  Link otwiera się w nowym oknie
Opis:
A new augmented Biderman model inspired by the modified couple stress theory has been introduced to investigate the size effect in addition to nonlinear material effects. Then, this model is used to investigate free vibration of a hyper-elastic microbeam. Classical Biderman strain energy does not include the effect of small size in hyper-elastic materials. In order to consider the effect of small size, terms inspired by the modified couple stress theory are added to the classical Biderman strain energy function. In order to provide the possibility of calculating these terms, a relation between the material constants in the hyper-elastic Biderman model and the linear elastic constants is obtained. The equations of motion of the microbeam is obtained based on the extended Hamilton principle, and then is solved using Galerkin discretization and perturbation methods. The effect of thickness to length scale ratio on the normalized frequency is studied for different modes. It is shown that when thickness gets larger in comparison with the length scale parameter, the normalized frequency tends to classical Biderman results. The results obtained are validated by results of the Runge-Kutta numerical method and indicate an excellent agreement. Mode shapes of the microbeam based on the classical and the augmented models are depicted, where the augmented model anticipates stiffer behavior for hyperelastic microbeams.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie masy modelowych mikroukładów za pomocą biosensorów beleczkowych
Determination of the mass of model microchids using microbeam sensor
Autorzy:
Obrzud, Jowita
Opis:
Niniejsza praca przedstawia zastosowanie biosensorów mikrobeleczkowych w badaniach masy prostych mikroukładów o rozmiarach mikrometrowych na podstawie artykułów naukowych, zarówno badaczy polskich, jak i zagranicznych. Ponadto w pracy opisana jest przykładowa procedura wykonywania pomiarów za pomocą biosensora beleczkowego Cantisens firmy Concentris, z uwzględnieniem najważniejszych zasad i reguł, dzięki którym możliwe jest uzyskanie poprawnych wyników. W pracy opisałam procedurę pomiarową dostępnych badań oraz zebrałam dostępne opracowania naukowe, których w polskiej nauce wciąż jest niewiele.
This work describes the application of a microbeam sensor in studies of simple microsystems basing on the scientific articles of Polish and foreign researchers. Moreover, the paper describes the process of performing measurements using Cantisens microbeam sensor from Concentris biosensor, taking into account the most important principles and rules, thanks to which it is possible to obtain correct results. In this work, I described the proper experimental procedures and collected available scientific studies, which are still scarce in Polish science.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Inne
Tytuł:
Static, free and forced vibration analysis of a delaminated microbeam-based MEMS subjected to the electrostatic force
Autorzy:
Razeghi-Harikandeei, A.
Azizollah Ganji, B.
Jafari-Talookolaei, R.-A.
Abdipour, A.
Tematy:
microelectromechanical systems (MEMS)
delaminated microbeam
static deflection
pull-in voltage
non-linear electrostatic force
Pokaż więcej
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Powiązania:
https://bibliotekanauki.pl/articles/38444172.pdf  Link otwiera się w nowym oknie
Opis:
In this paper, the delamination effect on the static and natural frequency response of a microbeam subjected to the nonlinear electrostatic force is studied using a semi-analytical approach for the first time. The Euler–Bernoulli beam assumption along with the non-classical modified couple stress theory is used to obtain the governing differential equation of motion and then a reduced-order model based on Galerkin’s decomposition method is obtained. At first the microbeam with very small delamination like an intact microbeam is solved and then the solution is compared with those reported in the literature and the solution obtained using 3D-coupled electromechanical software. After validation, the effects of delamination length and its locations in thickness and length directions on the microbeam behavior are investigated in details. It is shown that the delamination has remarkable effects on the characteristics of the microbeam, especially near the pull-in voltage. Also, the delaminated microbeam with various thicknesses is studied using both the classical and the non-classical theories. It is found that the difference between the two models is significant for the thin microbeam with a thickness near of below than its material length scale parameter. This investigation is helpful for the nondestructive detection of the delamination in the beams.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic detection of unstained viable cells in phase-contrast microscope images
Automatyczna detekcja żywych komórek niebarwionych w obrazach wykonanych mikroskopem fazowo-kontrastowym
Autorzy:
Skoczylas, M.
Cherubini, R.
Gerardi, S.
Tematy:
rozpoznawanie komórek niebarwionych
mikrowiązka jonowa
analiza obrazu
unstained cell recognition
charged-particle microbeam
image analysis
Pokaż więcej
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Powiązania:
https://bibliotekanauki.pl/articles/341089.pdf  Link otwiera się w nowym oknie
Opis:
Irradiation of cultured mammalian cells one-by-one with a known number of ions, down to one-ion per single-cell, is a useful experimental approach to investigate the low-dose ionizing radiation exposure effects and to contribute to a more realistic human cancer risk assessment. Mammalian cells (specifically, Chinese hamster V79 cells) are seeded and grown as a monolayer on a mylar surface used as bottom of the special designed holder, having as cover an other mylar foil and allowing the cell culture to be in wet and sterile conditions. Manual recognition of unstained cells in bright-field is a time consuming procedure, therefore a parallel algorithm has been conceived and developed in order to speed-up this step of the irradiation protocol and increase the number of cells that can be irradiated during an accelerator run. Many technical problems have been faced to overcome the complexity of the images to be analyzed. The unstained cells have to be discriminated in an inhomogeneous background, among many disturbing bodies mainly due to the mylar surface roughness and culture medium. Additionally, cells can have various shapes depending on how they attach on the surface, which phase of the cell cycle they are in and on cell density, thus making the detection task more difficult.
Precyzyjne napromieniowywanie żywych komórek biologicznych z użyciem znanej liczby jonów (z dokładnością do pojedynczej cząstki) pozwala na badanie efektów niskiej dawki promieniowania oraz dostarcza unikalnych danych służących ocenie ryzyka wystąpienia choroby nowotworowej jako konsekwencji ekspozycji na niskie dawki promieniowania jonizującego. Komórki ssaka (dokładniej chomika chińskiego, komórki V79) są hodowane w jednej warstwie na powierzchni folii wykonanej z cienkiego mylaru, użytej jako dolna część specjalnie do tego celu zaprojektowanej szalki, posiadającej jako przykrycie kolejną, wierzchnią warstwę folii, umożliwiając komórkom przebywanie w sterylnym otoczeniu. Płytka z komórkami jest skanowana pod mikroskopem, komórki są identyfikowane przez operatora oraz zapisywane są ich współrzędne; po tej procedurze próbka jest przesuwana z mikroskopu pod wiązkę i komórki są automatycznie napromieniowywane. Ręczne rozpoznawanie komórek niebarwionych w obrazach uzyskanych mikroskopem fazowo-kontrastowym jest bardzo czasochłonną procedurą, dlatego został zaprojektowany oraz zaimplementowany równoległy algorytm, aby przyspieszyć ten krok protokołu radiacji oraz by zwiększyć ilość komórek które mogą zostać napromieniowane w pojedynczym eksperymencie, którego czas powinien być skrócony do minimum. Napotkano wiele problemów w przezwyciężeniu trudności analizy tego rodzaju obrazów. Komórki niebarwione muszą zostać rozróżnione na niejednorodnym tle, pośród wielu dodatkowych obiektów, pochodzących głównie ze struktury folii mylar oraz środowiska w którym żyją komórki. Dodatkowo, kształty komórek są bardzo zróżnicowane, w zależności od sposobu w jaki przyczepiają się do powierzchni, w jakim cyklu komórkowym aktualnie przebywają oraz ich gęstości, powodując, iż rozwiązanie problemu rozpoznawania ich jest trudnym zadaniem.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified Couple Stress Theory for Micro-Machined Beam Resonators with Linearly Varying Thickness and Various Boundary Conditions
Autorzy:
Zenkour, A. M.
Tematy:
microbeam
temperature dependent properties
modified couple stress analysis
linear varying thickness
mikrowiązka
właściwości zależne od temperatury
zmodyfikowana analiza naprężeń momentowych
liniowo zmienna grubość
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/139912.pdf  Link otwiera się w nowym oknie
Opis:
This article employs the classical Euler–Bernoulli beam theory in connection with Green–Naghdi’s generalized thermoelasticity theory without energy dissipation to investigate the vibrating microbeam. The microbeam is considered with linearly varying thickness and subjected to various boundary conditions. The heat and motion equations are obtained using the modified couple stress analysis in terms of deflection with only one material length-scale parameter to capture the size-dependent behavior. Various combinations of free, simply-supported, and clamped boundary conditions are presented. The effect of length-to-thickness ratio, as well as the influence of both couple stress parameter and thermoelastic coupling, are all discussed. Furthermore, the effect of reference temperature on the eigenfrequency is also investigated. The vibration frequencies indicate that the tapered microbeam modeled by modified couple stress analysis causes more responses than that modeled by classical continuum beam theory, even the thermoelastic coupled is taken into account.
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies