Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "photon detector" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Reduction of silicon photomultipliers thermal generation in self-coincidence system applied in low level light measurements
Autorzy:
Baszczyk, M.
Dorosz, P.
Głąb, S.
Kucewicz, W.
Mik, Ł.
Tematy:
Silicon Photomultiplier
SiPM
thermal generation
photon detector
cosmic rays
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/201762.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents method for thermal generation reduction in low level light applications, especially where measured phenomena have random character. The algorithm was developed basing on cosmic ray measurements. The main parts of the system are: Silicon Photomultipliers (SiPM), front-end ASIC for amplifying and shaping signals. SiPM is a very sensitive device which can detect single photons. Comparing to a standard photomultiplier SiPM has a compact size, low operating voltage and it is immune to an electromagnetic field. Thermally generated signals are disadvantage of SiPM. This paper presents the measurement method to reduce influence of thermal generation.
Dostawca treści:
Biblioteka Nauki
Artykuł
Autorzy:
Tokgoz, Nazime
Algin, Oktay
Cademartiri, Filippo
Opis:
Photon-counting detector computed tomography (PCD-CT) devices have recently been introduced into practice, despite photon-counting detector technology having been studied for many years. PCD-CT devices are expected to provide advantages in dose reduction, tissue specificity, artifact-free imaging, and multi-contrast demonstration capacity. Noise reduction and increased spatial resolution are expected using PCD-CT, even under challenging scanning conditions. Some experimental or preliminary studies support this hypothesis. This pictorial review illustrates the features of PCD-CT systems, particularly in the interventional field. PCD-CT offers superior image quality and better lesion discrimination than conventional CT techniques for various conditions. PCD-CT shows significant improvements in many aspects of vascular imaging. It is still in its early stages, and several challenges have been identified. Also, PCD-CT devices have some important caveats. The average cost of these devices is 3 to 4 times higher than conventional CT units. This additional cost must be justified by improved clinical benefits or reduced clinical harms. Further investigations will be needed to resolve these issues.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Simulation study on improving the spatial resolution of photon-counting hybrid pixel X-ray detectors
Autorzy:
Krzyżanowska, Aleksandra
Szczygieł, Robert
Tematy:
charge sharing
subpixel resolution
pixel detector
hit allocation
single photon counting
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Powiązania:
https://bibliotekanauki.pl/articles/2063889.pdf  Link otwiera się w nowym oknie
Opis:
Hybrid pixel radiation detectors with a direct photon-to-charge conversion working in a single photon counting mode have gained increasing attention due to their high dynamic range and noiseless imaging. Since sensors of different materials can be attached to readout electronics, they enable work with a wide range of photon energies. The charge-sharing effect observed in segmented devices, such as hybrid pixel detectors, is a phenomenon that deteriorates both spatial resolution and detection efficiency. Algorithms that allow the detection of a photon irrespective of the charge-sharing effect are proposed to overcome these limitations. However, the spatial resolution of the detector can be further improved beyond the resolution determined by the pixel size if information about the chargé proportions collected by neighbouring pixels is used to approximate the interaction position. In the article, an approach to achieve a subpixel resolution in a hybrid pixel detector working in the single photon counting mode is described. Requirements and limitations of digital inter-pixel algorithms which can be implemented on-chip are studied. In the simulations, the factors influencing the detector resolution are evaluated, including size of a charge cloud, number of virtual pixel subdivisions, and detector parameters.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niechłodzone detektory fotonowe z (Hg,Cd)Te promieniowania 10,6 μm
Noncooled (Hg,Cd)Te IR photo detectors in range of 10.6 μm wavelength
Autorzy:
Niedziela, T.
Tematy:
detektor fotonów
detektor magnetoekskluzyjny
detektory podczerwieni w wysokiej temperaturze
photon detectors
high-temperature infrared detectors
magnetoexclusion detector
Pokaż więcej
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Powiązania:
https://bibliotekanauki.pl/articles/312369.pdf  Link otwiera się w nowym oknie
Opis:
W artykule dokonano analizy niechłodzonych (T=300K) fotodiod (PC) i detektorów magnetoekskluzyjnch (EMCD) promieniowania 10,6 μm. Obliczenia wykazały, że optymalne parametry fotodiod takie jak grubość czy domieszkowanie dla struktury na podłożu z poszerzoną przerwą energetyczną są inne niż dla konstrukcji z kontaktami omowymi na obu jej końcach. Ustalono optymalne parametry detekcyjne elementów dla fotodiod i detektorów magnetoekskluzyjnych z (Hg,Cd)Te pracujących w temperaturze pokojowej.
In range of 10.6 μm IR radiation an analysis of noncooled (T = 300 K) (PC) photodiodes and (EMCD) magnetoexlusion detectors with (Hg,Cd)Te was made. The basic detection parameters of these devices are limited by the noise resulting from statistical processes of thermal generation and carrier recombination. The parameter evaluation of related photodiodes demonstrates that the optimal parameters such as: thickness or structure doping on the substrate with a widened energy gap differs each other for structures with ohmic contacts at both ends. In the paper, for photodiodes and magnetoexclusion detectors with (Hg,Cd)Te the research results : optimal photosensitive detection parameters are presented for the room temperature (T=300 K) and acceptable large as well as small (5 and 0.5 W / mm2) densities of the dissipated power.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
SIDDHARTA-2 apparatus for kaonic atoms research on the DAΦNE collider
Autorzy:
Khreptak, Aleksander
Sirghi, F.
Niedźwiecki, Szymon
Guaraldo, C.
Sgaramella, F.
Friščić, I.
Silarski, Michał
Clozza, A.
Skurzok, Magdalena
Carminati, M.
Principato, F.
Sirghi, D.
Piscicchia, K.
Deda, G.
Bragadireanu, M.
De Paolis, L.
Marton, J.
Zmeskal, J.
Buttacavoli, A.
Fabbietti, L.
Scordo, A.
Vazquez Doce, O.
Iliescu, M.
Borghi, G.
Tüchler, M.
Curceanu, C.
Cargnelli, M.
Iwasaki, M.
Bazzi, M.
Napolitano, F.
Spallone, A.
Ohnishi, H.
Dulski, K.
Bosnar, D.
Abbene, L.
Manti, S.
Moskal, Paweł
Toscano, L.
Amsler, C.
Toho, K.
Del Grande, R.
Fiorini, C.
Opis:
SIDDHARTA-2 is a state-of-the-art experiment designed to perform measurements of kaonic atoms, which are exotic atoms composed of a negatively charged kaon orbiting nucleus. These atoms constitute an exceptional probe for investigating the strong interaction in the non-perturbative regime involving strangeness. The experiment is installed at the DAΦNE electron-positron collider of the INFN National Laboratory of Frascati (INFN-LNF) in Italy, aiming to perform the first-ever measurement of the 2p → 1s X-ray transitions in kaonic Deuterium, a crucial step towards determining the isospin-dependent antikaon-nucleon scattering lengths. Based on the experience gained with the previous SIDDHARTA experiment, which performed the most precise measurement of the kaonic Hydrogen 2p → 1s X-ray transitions, the present apparatus has been upgraded with innovative X-Ray Silicon Drift Detectors (SDDs), distributed around a cryogenic gaseous target placed in a vacuum chamber at a short distance above the interaction region of the collider, two new veto systems and a charged kaon detector. The current work presents a comprehensive description of the SIDDHARTA-2 setup, including the optimization of its various components during the commissioning phase of the collider.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Progress in digital industrial radiology. Pt. 1, Radiographic techniques – film replacement and backscatter imaging
Postępy w cyfrowej radiologii przemysłowej. Cz. 1, Techniki radiograficzne - sukcesor błony i obrazowanie rozproszone wstecznie
Autorzy:
Ewert, U.
Tematy:
digital radiography
computed tomography
laminography
imaging plates
digital detector arrays
photon counting detectors
back scatter
numeric modelling
CFRP
welding
corrosion
radiografia cyfrowa
tomografia komputerowa
laminografia
płyty obrazowe
cyfrowe detektory radiograficzne
detektory zliczające fotony
rozpraszanie wsteczne
modelowanie numeryczne
spawanie
korozja
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/107864.pdf  Link otwiera się w nowym oknie
Opis:
Similar to the success story of digital photography a major upheaval has been observed in digital industrial radiology. This paper is split into 3 parts: Part 1: Film Replacement and Backscatter Imaging: Computed radiography with phosphor imaging plates substitutes film applications. Digital Detector Arrays enable an extraordinary increase of contrast sensitivity in comparison to film radiography. The increased sensitivity of digital detectors enables the efficient usage for dimensional measurements and functionality tests substituting manual maintenance. The digital measurement of wall thickness and corrosion status is state of the art in petrochemical industry. Photon counting and energy discriminating detectors are applied up to 300 kV and provide increased thickness dynamic and material discrimination by synchronously acquisition of images of the high and low energy part of the spectrum. X-ray back scatter techniques have been applied in safety and security relevant applications with single sided access of source and detector. First inspections of CFRP in aerospace industry were successfully conducted with newly designed back scatter cameras. Numeric modeling is used to design X-Ray optics and inspection scenarios as well as conducting RT training. Part 2: Computed tomography (CT) Part 3: Micro Radiography and Micro CT.
Podobnie jak w przypadku fotografii cyfrowej tak i w cyfrowej radiografii przemysłowej nastąpiły poważne zmiany. Publikacja składa się z 3 części. Część 1.: Zastąpienie techniki analogowej i obrazowanie metodą rozproszenia wstecznego. Radiografia komputerowa z zastosowaniem ekranów luminoforowych (płyt obrazowych) zastępuje błony. Cyfrowe detektory radiograficzne DDA umożliwiają uzyskanie ponadprzeciętnego wzrostu czułości kontrastowej w stosunku do błony. Zwiększona czułość detektorów cyfrowych umożliwia wykorzystanie radiografii do określenia rozmiarów obiektów i przeprowadzenia testów funkcjonalnych, zastępując obsługę ręczną. Pomiar cyfrowy grubości ścianki i procesu korozji rozwinął się znacząco w przemyśle petrochemicznym. Detektory działające w trybie zliczania fotonów z dyskryminacją energetyczną, stosowane do 300 kV umożliwiają większą, dynamiczną rozróżnialność grubości i rodzaju materiału (akwizycja synchroniczna). Techniki związane z rozpraszaniem wstecznym promieniowania X zostały zastosowane w aplikacjach z dziedziny bezpieczeństwa i ochrony, w których źródło i detektor musiały znajdować się po tej samej stronie. Omawiane systemy obrazowania zostały również po raz pierwszy zastosowane do testowania kompozytów węglowych w przemyśle lotniczym. Modelowanie numeryczne zjawisk fizycznych związanych z radiografią jest wykorzystywane w projektowaniu optyki rentgenowskiej, opracowywaniu procedur kontroli materiałów i szkoleniach RT . Część 2: Tomografia komputerowa (CT) Część 3: Mikroradiografia i mikrotomografia komputerowa.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
AEgIS experiment at CERN : design and commissioning of SARA (Scintillator Assemblies to Reveal Annihilations)
Autorzy:
Consolati, G.
Lappo, L.
Moskal, Paweł
Berghold, M.
Sharma, Sushil
Conte, P.
Caravita, R.
Ferguson, R.
Penasa, L.
Grosbart, M.
Münster, M.
Khatri, G.
Guatieri, F.
Prata, M.
Haider, S.
Opis:
SARA is the system of plastic scintillators coupled with silicon photomultipliers that will take part in the AEgIS experiment at CERN, measuring the time-of-flight of antihydrogen as it falls through a moiré deflectometer. Its development focused on simplicity, versatility and economy of the design and was supported by both physical tests and numerical simulations. The instrument structure pairs the utilization of the scintillators as structural components with custom made 3D printed corner elements and the electronics allows selection between coincidence discrimination made on each scintillator and made between different scintillators.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies