Wyświetlanie 1-4 z 4
Tytuł:
Si-Based Electrodes for Potentiometric Measurements of Aqueous Solutions
Autorzy:
Zaborowski, M.
Tomaszewski, D.
Jaroszewicz, B.
Grabiec, P.
Tematy:
chlorine ion sensor
potentiometric sensor
p-n junction thermometer
Pokaż więcej
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Powiązania:
https://bibliotekanauki.pl/articles/308235.pdf  Link otwiera się w nowym oknie
Opis:
Three sensors for chemical and physical examination of aqueous solutions were presented in the paper. An Au potentiometric electrode, an AgCl chlorine ion sensor and a p-n junction thermometer were developed. Their layout and internal structure were explained in the light of the manufacturing process. The device characteristics were measured in conditions corresponding to normal operation of the devices. Basic electrical parameters of the developed structures, as well as their sensitivity to environmental parameter variation were estimated.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Konstrukcja i właściwości czujników potencjometrycznych do oznaczania ketoprofenu
Construction and properties of potentiometric sensors for ketoprofen determination
Autorzy:
Lenik, J.
Tematy:
czujnik potencjometryczny
elektroda z ciekłym kontaktem
elektroda ze stałym kontaktem
ketoprofen
potentiometric sensor
electrode with liquid contact
electrode with solid contact
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/157052.pdf  Link otwiera się w nowym oknie
Opis:
Celem prezentowanej pracy było skonstruowanie membranowych elektrod jonoselektywnych do oznaczania ketoprofenu. Zastosowano czujniki z ciekłym kontaktem ISE (typ IS 561, Philips) oraz czujniki ze stałym kontaktem typu BMSA (Zakład Chemii Analitycznej i Analizy Instrumentalnej UMCS) zawierające hydrofobowe pary jonowe w mikroporowatej (z polichlorku winylu) warstwie matrycowej. Wyznaczono podstawowe parametry analityczne czujników tj. zakres pomiarowy, nachylenie charakterystyki, granicę wykrywalności, współczynniki selektywności, czas odpowiedzi, zależność SEM od pH, czas życia.
The aim of the presented work was to create membrane ion-selective electrodes for ketoprofen determination. There were used sensors with liquid contact so called conventional ion-selective electrode ISE (type IS 561, Philips) and sensors with solid contact so called BMSA (Institute of Analytical Chemistry and Instrumental Analysis UMCS) containing hydrophobic ion pairs in the microporous (PVC) matrix layer. The latter electrode does not have any inner solution and it posses all the advantages of the "coated wire electrodes" (CWE). The following basic electrode parameters were investigated: measurement range, slope of characteristic, limit of detection, response time, dependence of the electrode potential on pH, lifetime and selectivity coefficients in relation to some organic and inorganic anions. The ketoprofen electrode was used for ketoprofen determination in the synthetic sample and pharmaceutical Ketonal (Lek Pharmaceuticals d.d. Slovenia) within the concentration range of 25.43 - 25430 žg/ml in water solution at pH 5.0 - 9.5. The statistical parameters (Recovery 100,6%, RSD =5,5%) show the typical accuracy of the analytical methods employing ion - selective electrodes.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potentiometric oxygen sensor with solid state reference electrode
Autorzy:
Dunst, K.
Jasinski, G.
Jasinski, P.
Tematy:
potentiometric
oxygen sensor
Nernstian behavior
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/220764.pdf  Link otwiera się w nowym oknie
Opis:
The concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited on the two sides of the electrolyte. In this paper different structures of potentiometric oxygen sensors with a solid state reference electrode were fabricated and investigated. The fabricated structures consisted of oxygen ion conducting solid electrolyte from yttria stabilized zirconia, a sensing platinum electrode and nickel-nickel oxide reference electrode. The mixture of nickel-nickel oxide was selected as the reference electrode because it provides reliable electrochemical potential in contact with oxygen conducting electrolyte. To avoid oxidation of nickel the reference electrode is sealed from ambient and the mixture of nickel-nickel oxide was formed electrochemically from nickel oxide after sealing. The effectiveness of the sealing quality and the effectiveness of nickel-nickel oxide mixture formation was investigated by impedance spectroscopy.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potencjometryczny sensor chloru
Potentiometric chlorine sensor
Autorzy:
Dziubaniuk, M.
Janora, S.
Pasierb, P.
Rękas, M.
Tematy:
sensory potencjometryczne
ogniwa stałe
sensor chloru
tlenochlorek lantanu
potentiometric gas sensors
solid cells
chlorine gas sensor
lanthanum oxy-chloride
Pokaż więcej
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Powiązania:
https://bibliotekanauki.pl/articles/155648.pdf  Link otwiera się w nowym oknie
Opis:
Do konstrukcji sensora chloru wybrano tlenochlorek lantanu, LaOCl, jako elektrolit stały. Jego warunki preparatyki określono metodą analizy termicznej oraz dyfrakcji promieniowania rentgenowskiego. Mikrostrukturę spieku elektrolitu określono przy użyciu mikroskopii elektronowej. Charakterystykę sensora wyznaczono dla koncentracji chloru w powietrzu w zakresie 0-100 ppm. Skonstruowany sensor pracuje poprawnie i jest stabilny w zakresie temperatur 500 - 800°C. Wyznaczona zależność napięcia źródłowego ogniwa od koncentracji chloru jest zgodna z prawem Nernsta dla n=2.
A chlorine gas sensor was fabricated with the Cl- ion conducting lanthanum oxy-chloride, LaOCl, a solid electrolyte. Preparation conditions, especially the optimal calcination temperature, were determined by means of the differential thermal analysis (DTA), thermogravimetry (TG) as well as mass spectrometry (MS). According to the x-ray diffraction (XRD) analysis, the product was homogenous and crystallized in tetragonal P4/nmm structure. Scanning electron microscopy (SEM) revealed that it is composed of uniform grains of the 210-260 nm dimension. The sensor manu-facture consisted of several steps. Firstly, the powder of LaOCl was pressed in pellet die (100 MPa) and calcined at 700°C for 2 hours. Then, both sides of polished pellet were covered with Pt paste. It was fired at 1100°C for 2 hours after cooling down the pellet was attached to Al2O3 tube using the ceramic binder to allow the separation of both electrode compartments during the sensor operation. The device was dried and heated at 370°C. The electromotive force (EMF) of the constructed cell was measured asa function of temperature (400- 800°C), Cl2 concentration in air (0-100 ppm) at sensing electrode and time. Air with constant concen-tration of chlorine (100 ppm) gas atmosphere was kept at reference electrode. The sensor exhibited reliable, stable and reproducible signal at operation temperature between 500 - 800°C. The deter-mined EMF vs. logp(Cl2) dependence may be described by the Nernst law for n= 2.
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies