Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sewer system" wg kryterium: Temat


Tytuł:
Some Models of Sediments Transport in Gravitational Sanitation Systems
Wybrane modele transportu osadów w systemach kanalizacji grawitacyjnej
Autorzy:
Jlilati, A.
Jaromin, K.
Widomski, M.
Łagód, G.
Tematy:
kanalizacja grawitacyjna
osady w kanalizacji
klasyfikacja osadów
transport osadów w kanalizacji
gravitational sewer system
sludge in sewer system
sludge classification
sludge transport in sewer system
Pokaż więcej
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/388651.pdf  Link otwiera się w nowym oknie
Opis:
The sediments in gravitational sanitation systems appear when the velocity of flow decreases below the value of hydraulic self-purification. These sediments have the significant influence on the processes occurring in the sanitation systems, causing inter alia the periodical fluctuation of loads entering the wastewater treatment plants. The sediments deposited in the channel are also causing the changes of the shape of pipe cross-section thus influencing the changes of physical and hydrodynamic parameters of the whole system. The sediments are also influencing the development of the sulphuric corrosion of pipes and intensity of biological biodegradation of wastewater in sanitation conduits. The research concerning the wastewater sediments and the connected processes are pretty costly so they are only being conducted in countries in which the biding law requires the mathematical modeling of mass transport to the wastewater plants and storm spillways. The results of this research give the necessary data to calibration of hydraulic models. The general description of structure and properties of sediments should be known at the stage of the consideration of minimal inclinations of conduits. It is also very important during the modeling of pollutants load transport in sanitation system and the process of wastewater biodegradation, because for different type and properties of sediments different model of transport should be used. The classification of sediments based on literature research and the results of classification research in sanitary systems in Chelm, Poland, as well as models often used for describing of sediment transport in gravitational conduits were presented.
Osady w kanalizacji grawitacyjnej występują w przypadku, gdy prędkość przepływu ścieków spada poniżej prędkości hydraulicznego samooczyszczania przewodów. Osady mają duży wpływ na procesy przebiegające w systemie kanalizacyjnym, powodując m.in. znaczne okresowe wahania ładunku w dopływie do oczyszczalni. Gromadzące się na dnie przewodów osady powodują również zmianę kształtu i pola powierzchni przekroju czynnego przewodu, a tym samym wpływają na zmianę parametrów fizycznych i hydrodynamicznych całego systemu. Osady wpływają też w dużej mierze na rozwój korozji siarczanowej kanałów oraz na intensywność procesów biodegradacji ścieków w przewodach kanalizacyjnych. Badania dotyczące osadów ściekowych oraz związanych z nimi procesów są dość kosztowne, więc prowadzi się je na szerszą skalę jedynie w tych krajach, gdzie regulacje prawne wymagają matematycznego modelowania transportu masy zanieczyszczeń do oczyszczalni ścieków oraz przelewów burzowych. Wyniki takich badań dostarczają danych niezbędnych do kalibracji odpowiednich modeli matematycznych. Ogólna charakterystyka struktury i właściwości osadów powinna być znana na etapie rozważania metody doboru minimalnych spadków dna kanałów grawitacyjnych, ma także duże znaczenie podczas modelowania transportu ładunków zanieczyszczeń w sieci kanalizacyjnej oraz powiązanych z tym zagadnieniem procesów biodegradacji ścieków. Właściwości osadów muszą być uwzględnione przy doborze modelu opisującego ich transport. Przedstawiono klasyfikację osadów na podstawie literatury krajowej i zagranicznej, modele stosowane do opisu transportu osadów w kanalizacji grawitacyjnej oraz zaprezentowano wyniki badań klasyfikacyjnych osadów zlokalizowanych w sieci kanalizacyjnej Chełma.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka osadów w wybranym systemie kanalizacji grawitacyjnej
Characteristics of sediments in chosen system of gravitational sanitation
Autorzy:
Jlilati, A.
Jaromin, K.
Widomski, M.
Łagód, G.
Tematy:
kanalizacja grawitacyjna
osady w kanalizacji
klasyfikacja osadów
transport osadów w kanalizacji
gravitational sewer system
sludge in sewer system
sludge classification
sludge transport in sewer system
Pokaż więcej
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/127265.pdf  Link otwiera się w nowym oknie
Opis:
Osady w kanalizacji grawitacyjnej występują w przypadku, gdy prędkość przepływu ścieków spada poniżej prędkości hydraulicznego samooczyszczania przewodów. Osady mają duży wpływ na procesy przebiegające w systemie kanalizacyjnym, powodując między innymi znaczne okresowe wahania ładunku w dopływie do oczyszczalni. Gromadzące się na dnie przewodów osady powodują również zmianę kształtu i pola powierzchni przekroju czynnego przewodu, a tym samym wpływają na zmianę parametrów fizycznych i hydrodynamicznych całego systemu. Osady wpływają też w dużej mierze na rozwój korozji siarczanowej kanałów oraz na intensywność procesów biodegradacji ścieków w przewodach kanalizacyjnych. Badania dotyczące osadów ściekowych oraz związanych z nimi procesów są dość kosztowne, więc prowadzi się je na szerszą skalę jedynie w tych krajach, gdzie regulacje prawne wymagają matematycznego modelowania transportu masy zanieczyszczeń do oczyszczalni ścieków oraz przelewów burzowych. Wyniki takich badań dostarczają danych niezbędnych do kalibracji odpowiednich modeli matematycznych. Ogólna charakterystyka struktury i właściwości osadów powinna być znana na etapie rozważania metody doboru minimalnych spadków dna kanałów grawitacyjnych, ma także duże znaczenie podczas modelowania transportu ładunków zanieczyszczeń w sieci kanalizacyjnej oraz powiązanych z tym zagadnieniem procesów biodegradacji ścieków. W prezentowanej pracy przedstawiono klasyfikację osadów opracowaną na podstawie przeglądu literatury krajowej i zagranicznej oraz zaprezentowano wyniki badań klasyfikacyjnych osadów zlokalizowanych w sieci kanalizacyjnej miasta Chełm.
Sediments in gravitational sanitation systems appear when the velocity of flow decreases below the value of the hydraulic self-purification. The sediments have the significant influence on the processes in the sanitation systems causing the periodical fluctuation of loads entering the wastewater treatment plants. The sediments deposited in the channel are also causing the changes of the shape of pipe cross-section thus influencing the changes of physical and hydrodynamic parameters of the whole system. The sediments are also influencing the development of the sulphuric corrosion of pipes and intensity of biological biodegradation of wastewater in sanitation conduits. The research concerning the wastewater sediments and the connected processes are pretty costly so they are only conducted in countries in which the biding law requires the mathematical modeling of mass transport to the wastewater plants and storm spillways. The results of this research give the necessary data to calibration of hydraulic models. The general description of structure and properties of sediments should be known at the stage of the consideration of minimal inclinations of conduits. It is also very important during the modeling of pollutants load transport in sanitation system and the process of wastewater biodegradation. The classification of sediments based on literature research and the results of classification research in sanitary systems in Chelm, Poland were presented in this study.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Conduit Geometrical Characteristics on Sewage Flow Parameters
Wpływ charakterystyk geometrycznych kanału na parametry przepływu ścieków
Autorzy:
Jlilati, A.
Jaromin, K.
Widomski, M.
Łagód, G.
Tematy:
kanalizacja grawitacyjna
parametry hydrodynamiczne przewodów kanalizacyjnych
gravitational sewer system
parameters of flow hydrodynamics
calibration of sewer system
Pokaż więcej
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/388101.pdf  Link otwiera się w nowym oknie
Opis:
The shape of sanitary conduits consistently defines the cross-section of the wastewater stream, which influences the basic parameters of flow hydrodynamics. The most important of these parameters are wetted perimeter and hydraulic radius, the values commonly used in sanitation systems designing and their work condition modeling. The determination of these parameters is quite simple in case of new conduits in a good technical condition, without the sediments. During the determination of old channels discharge capacity and their work modeling the providing for the sediments deposition is necessary. Deposits covering the bottom of sanitation conduits influence the hydraulic resistance of flow in three different ways: decreasing the cross-section area of the stream, increasing the roughness of the side walls and bottom of the pipe and decreasing the kinetic energy of the stream. The simulation of sanitary network working conditions concerning sediments may have a very important practical meaning. The storm spillways deliveries of the pollutant load included in sediments are, in some cases equal to yearly mean value of pollution contained in treated wastewater delivered to the rivers were observed. Additionally, the variable load of sediments causes non-uniform strain of wastewater treatment plants. The conducted in situ research showed that the height of deposited sediments sometimes was higher than the height of an active area of the stream. The analysis of changes in channel characteristics caused by sedimentation process and their influence on sewage flow parameters were presented. The gained results of calculations showed that sediments bed deposited in the 0.4, 0.5, 0.6 and 0.8 m diameter pipe caused maximum decrease of its wetted perimeter equal to 23.6 %, 22.9 %, 22.3 %, 21.6 % and 39.6 %, 38.7 %, 38.3 %, 37.9 % reduction of actual hydraulic radius value, respectively. The further research concerning other diameters and different shapes of sewer conduits should be conducted.
Kształt kolektora kanalizacyjnego w sposób jednoznaczny definiuje przekrój poprzeczny strumienia ścieków, który z kolei wpływa na podstawowe parametry związane z hydrodynamiką przepływu. Najważniejsze z tych parametrów to obwód zwilżony i promień hydrauliczny, czyli wielkooeci standardowo wykorzystywane w pracach projektowych systemu kanalizacyjnego oraz przy symulacjach komputerowych pracy tych systemów. Wyznaczenie tych parametrów jest stosunkowo proste w przypadku wspomnianych nowych kolektorów w dobrym stanie technicznym, bez złogów osadów. Przy określaniu przepustowości starych kanałów oraz modelowaniu ich pracy niezbędne staje się uwzględnianie osadów odkładających się na dnie kanałów oraz narastających na ściankach. Osady zalegające na dnie przewodów kanalizacyjnych mają wpływ na opory hydrauliczne przepływu na trzy różne sposoby, a mianowicie: zmniejszają przekrój wewnętrzny kanału, zmieniają szorstkość ścian i dna oraz podczas rozmywania nagromadzonych złogów zmniejszają energię strumienia przepływających ścieków. Symulacja pracy sieci kanalizacyjnej z uwzględnieniem odkładających się osadów wydaje się mieć duże znaczenie praktyczne, z uwagi na fakt odprowadzania z sieci ogólnospławnych przez przelewy burzowe do wód odbiornika ładunku zanieczyszczeń zawartego w osadach, którego wartość średnia w skali rocznej odpowiada ładunkowi odprowadzanemu z oczyszczalni wraz z oczyszczonymi ściekami. W przypadku sieci rozdzielczej okresowo wymywane osady wpływają także na nierównomierne obciążenie ładunkiem oczyszczalni ścieków. Podczas prowadzonych pomiarów terenowych zaobserwowano, iż wysokość złogów osadów przekraczała niekiedy wysokość czynnego przekroju strumienia ścieków. Zaprezentowano w pracy analizę wpływu zmian charakterystyk kanału wywołanych przez proces sedymentacji osadów na parametry przepływu ścieków. Osady zsedymentowane na dnie przewodów o średnicy 0,4, 0,5, 0,6 oraz 0,8 m powodować mogą zmniejszenie obwodu zwilżonego maksymalnie o 23,6 %; 22,9 %; 22,3 %; 21,6 % oraz promienia hydraulicznego o 39,6 %; 38,7 %; 38,3 % i 37,9 %. Należy przeprowadzić kolejne badania rozwojowe dotyczące innych średnic, kształtów oraz materiałów przewodów kanalizacyjnych.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The problem of extraneous water in sanitary sewer systems in Poland and France
Autorzy:
Kaczor, G.
Pujol, L.
Stęplewski, B.
Tematy:
sewage
sewer system
i/i
extraneous water
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Powiązania:
https://bibliotekanauki.pl/articles/100993.pdf  Link otwiera się w nowym oknie
Opis:
The objective of this research was to compare the amount of extraneous water flowing into selected gravitational separate sewer systems which discharge domestic sewage from the settlement of single-family houses in Poland and France during a year with a standard annual amount of precipitation. The study included a total of four sewer systems, including two operating in Poland and discharging the sewage from settlements near Krakow in the Malopolska Province and two systems operating in France and discharging the sewage from settlements of single-family houses near Lorient, Brittany, Morbihan Department. As part of the analysis, an average daily tributaries of extraneous water into sewers under the research, values of addition and share of this water were compared. Analysis of the research results demonstrated that the hydraulic load of sewer systems with extraneous water does not depend on the age of the sewer system, but mainly on the number of house drains, and to a lesser extent its length. It was also determined that the average daily amount of extraneous water flowing into sanitary sewer systems in wet weather is 0,107 m3 ·d-1 per 1 sewer connection. The study showed that tributaries of extraneous water into the separate sewer system occurring during the intense precipitation are a major operating problem both in Poland and France.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the distribution of statistical concentrations of pollutants in samples of treated wastewater from small sewage treatment plants
Autorzy:
Kaczor, Grzegorz B.
Tematy:
pollutants
sewer system
significance test
statistical distribution
treatment plant
Pokaż więcej
Wydawca:
Instytut Technologiczno-Przyrodniczy
Powiązania:
https://bibliotekanauki.pl/articles/2174301.pdf  Link otwiera się w nowym oknie
Opis:
The aim of the research was to show which theoretical statistical distribution best reflects and describes the variability of pollutant concentrations in treated sewage, discharged from small sewage treatment plants, characterised by a value below 2000 PE. The statistical analysis additionally takes into account the influence of the number of measuring sequence data on the shape and level of the distribution fit. The data for the research were obtained from three small sewage treatment plants, operating in the Lesser Poland, 10, 11 and 14 km from Kraków. Due to their size, these facilities are included in the group of treatment plants below 2000 PE. The research was conducted for 10 years. In the statistical analysis, 20-, 40-, 60- and 80-element data series were used, including the values of biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr) and total suspended solids (TSS), determined in samples of treated wastewater. Two commonly used tests, Kolmogorov-Smirnov λ and Pearson’s χ2 test were used to assess the fit of the theoretical statistical distribution to the empirical data distribution. Statistical analysis showed that the studied communities were characterised by an asymmetric, right-oblique distribution. Most often, the empirical distribution of the analysed measurement sequences was consistent with the Fisher-Tippett distribution. On the basis of the χ2 test, this distribution was described by a total of 31 out of 36 analysed groups at the significance level of a = 0.05. Other distributions that often describe the analysed empirical data are: Gamma, log-normal, Chi-square, and Weibull. The common feature of these distributions is usually asymmetry, right oblique. The skewness value ranges from 0.15 to 1.69.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reaerakcja ścieków w kanalizacji grawitacyjnej
Reaeration of sewage in gravitational sewe system
Autorzy:
Łagód, G.
Tematy:
kanalizacja grawitacyjna
powietrze w przewodach kanalizacyjnych
reaeracja ścieków
biodegradacja ścieków w przewodach kanalizacyjnych
gravitational sewer system
atmosphere of sewer pipes
reaeration of sewage
sewage biodegradation in gravitational sewer system
Pokaż więcej
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/126922.pdf  Link otwiera się w nowym oknie
Opis:
Stopień natlenienia ścieków ma kluczowe znaczenie dla tlenowych procesów biodegradacji zanieczyszczeń, przeprowadzanych przez biomasę heterotroficzną bytującą w systemie kanalizacyjnym. Stopień ten zależy od wielu czynników, z których najważniejsze to stężenie tlenu w powietrzu ponad swobodnym zwierciadłem ścieków, pole powierzchni kontaktu ścieków i powietrza oraz właściwości hydrodynamiczne przepływu. Gazy powstające w kanalizacji oprócz uciążliwości zapachowej mogą stanowić zagrożenie zdrowia i życia osób odpowiedzialnych za eksploatację i konserwację kanałów. Aby zminimalizować skalę opisanych problemów, projektuje się sieci kanalizacyjne w sposób zapewniający skuteczną ich wentylację, co przy prawidłowej realizacji projektu oraz odpowiednim stanie technicznym elementów systemu skutkuje składem powietrza w kanalizacji zbliżonym do składu powietrza atmosferycznego. Na podstawie przeglądu literatury oraz badań terenowych prowadzonych w miastach Lublin i Chełm przyjęto, iż stężenie tlenu w kolektorze ponad swobodnym zwierciadłem ścieków jest takie samo jak w powietrzu atmosferycznym (podczas badań prowadzonych w poprawnie funkcjonujących kolektorach kanalizacyjnych tylko w jednym punkcie zanotowano stężenie tlenu poniżej 18%). Założenie takie jest spełnione dla większości sytuacji występujących w kanalizacji grawitacyjnej i znacznie ułatwia opis procesów tlenowych w biomasie zawieszonej w toni ścieków i błonie biologicznej zanurzonej w ściekach. Proces reaeracji ścieków w kolektorach kanalizacji grawitacyjnej opisano za pomocą równań uwzględniających między innymi stężenie tlenu rozpuszczonego w ściekach, w równowadze z atmosferą, współczynniki wpływu detergentów i temperatury oraz wyznaczany empirycznie ogólny współczynnik transferu tlenu.
The grade of sewage aeration has an essential importance for aerobic processes of pollutants biodegradation occurring in the sewer systems. This grade depends on many factors with the most important are oxygen concentration in the atmosphere over the sewage surface and dimension of sewage - air surface contact as well as the hydrodynamic flow properties. The gases occurring in sewer system besides odor problems can threat health and life of people responsible for exploitation and conservation of the canals. To minimize the described problems, sewer systems are designed in the way preserving the efficient ventilation, which with proper design realization and the good conditions of system elements result in composition of conduit atmosphere close to atmospheric air. Basing on the literature review and field examination of conduits in cities of Lublin and Chelm it was assumed that atmosphere composition in sewer over the sewage surface is similar to the atmospheric air (during examination conducted in properly functioning sewers, oxygen concentration in only single point fall below 18%). This assumption is suitable for the majority of situations occurring in gravitational sanitation system and it visibly makes easier the description of aerobic processes in suspended biomass and biofilm growing in sewer pipes. The reaeration of wastewater in gravitational sewer systems are described by mathematical formulas considering coefficient of oxygen saturation in sewage in equilibrium with atmosphere, coefficient of detergent and the temperature influence as well as general coefficient of oxygen transfer.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of the flexible manhole-soil interaction in mining areas based on the laboratory test results
Autorzy:
Janoszek, Tomasz
Kalisz, Piotr
Zięba, Magdalena
Tematy:
soil-structure interaction
soil deformation
sewer system
cross-sectional deflection
numerical modelling
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Wydział Geoinżynierii, Górnictwa i Geologii. Instytut Górnictwa
Powiązania:
https://bibliotekanauki.pl/articles/58972407.pdf  Link otwiera się w nowym oknie
Opis:
Horizontal soil strains, caused by underground mining, change the distribution and values of loads acting on a manhole. The result of a significantly unbalanced distribution of horizontal loads on a flexible manhole is the cross-sectional deflection, which causes passive soil pressure. These loads may damage manholes, leading to failures of the sewer system. The article employs numerical modelling to analyse the interaction between a flexible manhole and horizontally strained soil for the conditions of the performed laboratory tests. The numerical simulations were conducted with FLAC3D v.5.0. software, based on the finite difference method. The numerical analyses showed that in mining areas the cross-sectional deflection of flexible manhole risers depends on the horizontal soil strains, the ring stiffness of the risers and the foundation depths of manholes.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model symulacyjny kanalizacji podciśnieniowej w Lubiechowie
Simulation model of vacuum sewer system in Lubiechów
Autorzy:
Ogiołda, E.
Strycki, O.
Tematy:
kanalizacja podciśnieniowa odprowadzanie ścieków
obliczenia symulacyjne
vacuum sewer system
simulation calculation
Pokaż więcej
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Powiązania:
https://bibliotekanauki.pl/articles/372408.pdf  Link otwiera się w nowym oknie
Opis:
Jednym ze sposobów odprowadzania ścieków na terenach wiejskich jest kanalizacja podciśnieniowa. W artykule omówiono zasadę działania systemu i metodykę wymiarowania poszczególnych jego elementów na przykładzie sieci kanalizacyjnej w Lubiechowie. Przedstawiono także możliwość opracowania przy użyciu programu EPANET modelu symulacyjnego będącego narzędziem do analizy różnych wariantów pracy sieci.
One of wastewater transport methods applied for a small number of houses in villages is vacuum system. In this paper its rules of operation and calculation of system elements in Lubiechów were shown. Results of calculation and possibilities of simulation model prepared in EPANET advantages were also presented.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Miejski staw bezodpływowy jako odbiornik ścieków deszczowych (na przykładzie Stawu Koziorożca w warszawskiej dzielnicy Włochy)
Urban pond without outflow as a resiver of rainwater (Koziorożec Pond example in the Włochy district in Warsaw)
Autorzy:
Dąbkowski, Sz. L.
Rydałowski, M.
Szymczuk, P.
Tematy:
kanalizacja deszczowa
staw
zlewnia zurbanizowana
rain water sewer system
pond
urban catchment
Pokaż więcej
Wydawca:
Instytut Technologiczno-Przyrodniczy
Powiązania:
https://bibliotekanauki.pl/articles/339646.pdf  Link otwiera się w nowym oknie
Opis:
W pracy omówiono funkcjonowanie stawu bezodpływowego, jako małego zbiornika retencyjnego w zlewni zurbanizowanej, znajdującego się na terenie dzielnicy Włochy m. st. Warszawy. Przedstawiono jego uwarunkowania przyrodnicze, hydrogeologiczne i urbanistyczne oraz czynniki, warunkujące poziom wody w stawie. Szczególną uwagę zwrócono ma rolę stawu jako odbiornika wód deszczowych. Określono zlewnię całkowitą oraz zlewnie cząstkowe, przypadające na poszczególne przewody kanalizacji deszczowej, mające swoje wyloty w omawianym stawie. Wydzielono jednolite rodzaje powierzchni zlewni oraz obliczono odpowiadające im współczynniki spływu. Na podstawie danych meteorologicznych obliczono dopływy wody do stawu o różnym prawdopodobieństwie wystąpienia. Przykład Stawu Koziorożca pokazuje, że na obszarach miejskich zbiorniki o takim charakterze mogą być skutecznie wykorzystywane jako odbiorniki wód deszczowych. Przyczyniają się do wzrostu zasobów wody podziemnej, zwiększają atrakcyjność rekreacyjną obszaru oraz stanowią walor przyrodniczy. Jednak ciągła zabudowa terenów, uszczelnianie powierzchni gruntu oraz występowanie ekstremalnych zjawisk pogodowych wymuszają kompleksowe spojrzenie na zagospodarowanie wód opadowych w miastach. Należy brać pod uwagę ryzyko, wynikające z przepełnienia zbiornika, które spowodowałoby szkody i straty materialne.
This paper presents the functioning of a pond without outlet in urbanized catchment located in the Włochy district in Warsaw. Natural surroundings of the pond, its hydrogeological and urban determinants affecting water level were characterised in the study. Particular attention was focussed on the pond as rainwater receiver. The total catchment and sub-catchments with sewer systems drailing rainwater from each into the pond were determined. The catchment area was divided into uniform types of surface and respective values of runoff coefficient were calculated. The inflow of water into the pond with varying degrees of probability of occurrence were calculated based on meteorological data. Koziorożec Pond is an example that small urban reservoirs may be effectively used as rainwater receivers. They contribute to the increase of ground water resources and enhance the recreational attractiveness of the area. However, continuous urbanization, tightening of ground surfaces and the occurrence of extreme weather events enforce a comprehensive look at stormwater management in urban areas. Risks arising from reservoir overfill, which would cause property damage, should also be taken into account.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies