Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "toric" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Aspherical, sphero-cylindrical, toroidal, and ellipsoidal surfaces for designing astigmatic spectacle lenses with axis orientation
Autorzy:
Xiang, Huazhong
Wang, Peng
Zheng, Zexi
Zheng, Gang
Chen, Jiabi
Wang, Cheng
Zhang, Dawei
Zhuang, Songlin
Tematy:
toric
astigmatism
spherocylinder
aspheric
ellipsoidal surface
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/27310110.pdf  Link otwiera się w nowym oknie
Opis:
In this paper, formulas for aspherical, sphero-cylindrical, toroidal, and ellipsoidal surfaces with astigmatic axes are derived. Based on this, four types of curved surfaces were designed to correct astigmatism with axis, and, subsequently, the lenses were simulated, fabricated, and measured. A total of ten spectacle lenses in two groups were designed. Those in the first group used identical optical parameters. The spherical and cylindrical powers and maximum and minimum edge thicknesses of aspherical, sphero-cylindrical, and ellipsoidal surfaces were compared. The results indicated that the power of the lens constructed using the toroidal surface was more accurate than those of the other three lenses. Moreover, the minimum edge thickness of the toroidal surface was 1.2%, 4.98%, and 4.87% lower than those of the aspherical, sphero-cylindrical, and ellipsoidal surfaces, respectively. The powers and edge thicknesses of toroidal surfaces with different diopters were compared in the second group. The minimum and maximum edge thicknesses were observed to be reduced by 8.97% and 6.05%, respectively, corresponding to the conic constants obtained via ray tracing. The conclusion will be significant for clinical ophthalmology and optical design for the patients with astigmatism.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Toric Structures on Symplectic Orbifolds
Struktury Toryczne na Symplektycznych Orbifoldach
Autorzy:
Sheshko, Nikolay
Opis:
W tej pracy rozpatrujemy symplektyczne orbifoldy toryczne, oraz przedstawiamy obszerny materiał teoretyczny zarówno o geometrii torycznej, jak i o orbifoldach. Wykorzystujemy ten materiał aby podać nowe przykłady torycznych orbifoldów z jedyną strukturą toryczną. Naszymi głównymi narzędziami są ważony pierścień Stanley'a-Reisnera oraz odpowiedniość Lermana-Tolman pomiędzy orbifoldami torycznmi a oznakowanymi wymiernymi wielościanami.
In this work we study symplectic toric orbifolds and gather an extensive theoretic material both on toric geometry and on orbifolds. Afterwards we use this material to provide new examples of toric orbifolds with unique toric structures. Our main tools are weighted Stanley-Reisner ring and a Lerman-Tolman correspondence between toric orbifolds and rational labeled polytopes.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Inne
Tytuł:
Optimal transport on completely integrable toric manifolds
Autorzy:
Myga, Szymon
Opis:
Following the work of Berman and Witt Nyström we present the proof of existence and uniqueness of solutions to transported Monge-Ampère problem on complex compact manifolds with completely integrable torus action. The proof is based on the real theory of optimal transportation and some convex analysis.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Tytuł:
Witrektomia tylna z fiksacją transskleralną soczewki torycznej oraz asystą systemu Verion – opis przypadku
Posterior vitrectomy with transscleral fixation of the toric lens and the assistance of the Verion system – case report
Autorzy:
Kuc, Tomasz
Pawlikowski, Rafał
Zuterek, Martyna
Gołębiowska, Monika
Pyrzanowski, Piotr
Tematy:
fiksacja transskleralna
witrektomia
soczewka toryczna AcrySof
Verion
AcrySof Toric IOL
transscleral fixation
vitrectomy
Pokaż więcej
Wydawca:
Medical Education
Powiązania:
https://bibliotekanauki.pl/articles/1035143.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents the original technique of transcleral fixation toric IOL with the assist of the Verion™ system in patients in which intracapsular implantation cannot be performed. This technique enables to predict the location of the fixation and the lens setting in the correct axis for astigmatism. In the paper we defined the term of angle of lens fixation, the means of its measurement as well as modification of Verion™ system setting. It enabled us to designate target location of lens fixation. The technique improved the refraction of the patient, by which the implant could not be done by classical method.
Praca przedstawia zastosowanie oryginalnej techniki fiksacji przeztwardówkowej soczewki torycznej z asystą systemu Verion™ u chorych, u których nie można dokonać dotorebkowego wszczepienia implantu. Technika ta umożliwia wytypowanie miejsca fiksacji i ustawienie soczewki w prawidłowej osi astygmatyzmu. W pracy zdefiniowaliśmy pojęcie kąta fiksacji soczewki, sposób jego pomiaru, a także sposób modyfikacji ustawień systemu Verion™. Pozwoliło nam to wyznaczyć docelowe miejsce fiksacji soczewki. Technika ta poprawiła refrakcję u chorej, u której nie można było dokonać wszczepienia metodą klasyczną.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Psychomotor education, an aspect of general formation of the pre-school children
Autorzy:
Shingjergji, Ardian
Tematy:
education psychomotor, motoric experience, kindergarten children, run mo-toric development, model motors skills progress.
Pokaż więcej
Wydawca:
Fundacja Pro Scientia Publica
Powiązania:
https://bibliotekanauki.pl/articles/628751.pdf  Link otwiera się w nowym oknie
Opis:
Current developments of scientifi c thinking in the fi eld of education, are increasingly de-manding in various disciplines for young people as a matter of urgency. It is already known that child development is conditioned by ancestry, socio-cultural environment, including interaction with peers and adults. Albanian institutions (kindergarten) compared to contem-porary experience in more developed countries have to deal with issues such as: (1) The de-velopment of a run or optimal acceleration enrichment motor for kindergarten children, seen as an important element of the formation of the human personality and its preparation to cope with various situations of life ; (2) The role of infrastructure in the natural development of the personality of children and the educational process as a whole; (3) Parental community involvement as a fundamental prerequisite of real development of the child; (4) The qualifi -cation level of the teaching staff in the elementary education system and the preparation of students teacher. I hope to add my contribution through this paper, not only by identifying the problems abo-ve, but also in presenting alternatives of a development model of kindergarten children motors skills progress, compared to contemporary experience in more developed countries.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie wewnątrzgałkowych wieloogniskowych soczewek torycznych w korekcji prezbiopii oraz astygmatyzmu rogówkowego w chirurgii zaćmy – analiza wyniku refrakcji i stabilności osiowej soczewki AcrySof IQ PanOptix TFNTx
Application of intraocular multifocal toric lenses in the correction of presbyopia and corneal astigmatism in cataract surgery – analysis of the refraction outcome and axial stability of the AcrySof IQ PanOptix TFNTx Intraocular Lens
Autorzy:
Klonowski, Paweł
Prokopiuk, Agata
Tematy:
astygmatyzm rogówkowy
operacja zaćmy
prezbiopia
wieloogniskowe soczewki toryczne
: presbyopia
corneal astigmatism
cataract surgery
multifocal toric intraocular lenses
Pokaż więcej
Wydawca:
Medical Education
Powiązania:
https://bibliotekanauki.pl/articles/1034910.pdf  Link otwiera się w nowym oknie
Opis:
Purpose: To evaluate distance, near and intermediate visual acuity, objective refraction, corneal keratometry and rotational stability after cataract surgery with an implantation of multifocal toric AcrySof® IQ PanOptix TFNTx intraocular lens in one-year follow-up. Material and methods: A total of 20 eyes of 14 patients underwent 2.2 mm coaxial cataract surgery with an implantation of AcrySof® IQ PanOptix TFNTx intraocular lens. Before surgery uncorrected and best-corrected distance visual acuity, objective refraction and corneal keratometry were evaluated. Twelve months after the surgery uncorrected and best-corrected distance visual acuity, uncorrected near and intermediate visual acuity, objective refraction, corneal keratometry and rotational stability of the implant were analyzed. Results: One year after the surgery there was statistically significant improvement of uncorrected and best corrected distance visual acuity (p = 0.005 and p = 0.016). There was no significant change in corneal keratometry in flat and steep meridian (p = 0.94 and p = 0.63) and keratometric cylinder (p = 0.49). There was statistically significant decrease in objective refraction cylinder (p = 0.002). The mean rotation of an implanted intraocular lens axis was 2.51°. There were no intra- and post-operative complications in any of the patients. Conclusions: AcrySof® IQ PanOptix TFNTx intraocular lens implantation is a safe and effective method to correct presbyopia coexisting with corneal astigmatism during cataract surgery
Celem pracy jest ocena wyników ostrości wzroku do dali, bliży i odległości pośredniej, refrakcji obiektywnej, keratometrii rogówkowej oraz stabilności rotacyjnej soczewki u pacjentów poddanych operacji zaćmy z implantacją wieloogniskowej soczewki torycznej AcrySof® IQ PanOptix TFNTx w rocznym okresie obserwacji.Materiał i metody_ Do badania włączono 20 oczu 14 pacjentów. Poddano ich operacji zaćmy metodą koaksjalnej fakoemulsyfikacji z szerokością cięcia rogówkowego 2,2 mm oraz z implantacją soczewki AcrySof® IQ PanOptix TFNTx. Przed zabiegiem oceniono ostrość wzroku do dali bez korekcji i z najlepszą korekcją, refrakcję obiektywną oraz keratometrię rogówkową. 12 miesięcy po operacji oceniono ostrość wzroku do dali bez korekcji i z najlepszą korekcją, ostrość wzroku do odległości pośredniej bez korekcji, ostrość wzroku do bliży bez korekcji, refrakcję obiektywną, keratometrię rogówkową oraz stabilność rotacyjną implantu w torebce.Wyniki_ W rocznym okresie obserwacji zanotowano istotną statystycznie poprawę ostrości wzroku do dali bez korekcji i z najlepszą korekcją (p = 0,005 oraz p = 0,016). Nie zaobserwowano istotnej statystycznie zmiany w wielkości keratometrii rogówkowej w południku płaskim i stromym (p = 0,94 oraz p = 0,63) oraz w wielkości cylindra rogówkowego (p = 0,49). Odnotowano istotne statystycznie zmniejszenie mocy cylindrycznej w refrakcji obiektywnej (p = 0,002). Średnie odchylenie osi wszczepionej soczewki od zaplanowanej osi implantacji wyniosło 2,51°. Nie zaobserwowano powikłań śród- ani pooperacyjnych u żadnego z pacjentów.Wnioski_ Implantacja wieloogniskowej torycznej soczewki AcrySof® IQ PanOptix TFNTx jest bezpiecznym i efektywnym sposobem leczenia prezbiopii współistniejącej z astygmatyzmem rogówkowym w trakcie operacji zaćmy.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Degeneracje toryczne gładkich powierzchni Del Pezzo
Toric degeneration Del Pezzo surfaces
Autorzy:
Gołębiowski, Łukasz
Opis:
This paper gives an overview of the theory of smooth Del Pezzo surfaces and their relationship with the mirror symmetry. It was showed known fact that there are exactly five smooth toric Del Pezzo surfaces. In the next section we propose own method to search for candidates for a smooth toric degeneration. Using this method we make degeneration of non-toric smooth Del Pezzo surface to surface toric. In the last chapter it was computed singularities of toric surfaces obtained in this degeneration.
W pracy przedstawiamy zarys teorii gładkich powierzchni Del Pezzo oraz ich związek z symetrią lustrzaną. Następnie pokazujemy znany już fakt, że spośród dziesięciu gładkich powierzchni Del Pezzo, dokładnie pięć są powierzchniami torycznymi. W kolejnym rodziale proponujemy autorską metodę szukania kandydatów na płaską degenerację toryczną. Korzystając z tej metody dokonujemy degeneracji pozostałych nietorycznych gładkich powierzchni Del Pezzo do powierzchni torycznych. Należy zaznaczyć, że podane w pracy przykłady degeneracji prawdopodobnie nie wyczerpują wszystkich możliwości. W ostatnim rozdziale liczymy osobliwości powierzchni torycznych uzyskanych w degeneracji.Motywacją tematu pracy były ostatnie wyniki Victora Przyjalkowskiego oraz grupy badawczej kierowanej przez Alessio Cortie'go. Przytoczeni autorzy wskazali na mocny związek między degeneracjami rozmaitości Fano do rozmaitości torycznych a modelem Landau-Ginzburg. Model Landau-Ginzburg daje daje wysoką nadzieję na dokonanie klasyfikacji czterowymiarowych rozmaitości Fano. Warto zaznaczyć, że najdalej posunięte wyniki w zakresie gładkich rozmaitości Fano to klasyfikacja trójwymiarowcyh rozmaitości dokonanych niezależnie przez V. Iskovskiha oraz dwóch matematyków S. Mori i S. Mukai ponad trzydzieści lat temu.
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Inne
Tytuł:
Preliminary results of the ground penetrating radar (GPR) prospection in the areaof the prehistoric flint mine Borownia, south eastern Poland
Autorzy:
Mieszkowski, Radosław
Welc, Fabian
Budziszewski, Janusz
Migal, Witold
Bąkowska, Anna
Tematy:
ground pen e trat ing ra dar
ar chae o log i cal site
pre his toric flint mine
Borownia
Po land
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/2027101.pdf  Link otwiera się w nowym oknie
Opis:
Pre lim i nary re sults of GPR field prospection car ried out in the area of the pre his toric min ing field Borownia (Æmielów, Ostrowiec OEwiêtokrzyski Dis trict) are pre sented. This min ing field forms a belt (30–50 m wide and 700 m long), start ing from the val ley edge of the Kamienna River southeastwards. South east ern and west ern parts of the site have pre served the orig i nal post-ex ploi ta tion re lief. Ge ol ogy of the Borownia min ing field was ex am ined and ac quired radio grams re vealed three dis tinct zones of anom aly con cen tra tions. The cen tral zone (B) is clearly a frag ment of the pre his toric min ing field, con firmed not only by the GPR sound ing but also by ar chae o log i cal sur veys. The other two zones have not yet been in ves ti gated in de tail but their sur face and ar chae o log i cal ex am i na tion may de ter mine only whether their un der ground struc tures are nat u ral or have been cre ated by hu mans. Data ob tained dur ing the GPR prospection at the Borownia ar chae o log i cal site con firmed use ful ness of 100, 250 and 500 MHz an ten nas. The rel atively large depth range and good res o lu tion are due to fa vor able geo log i cal con di tions.
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies