Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "vertical flow" wg kryterium: Temat


Tytuł:
The Efficiency of Pollution Removal From Domestic Wastewater in Constructed Wetland Systems With Vertical Flow With Common Reed and Glyceria Maxima
Autorzy:
Dębska, A.
Jóźwiakowski, K.
Gizińska-Górna, M.
Pytka, A.
Marzec, M.
Sosnowska, B.
Pieńko, A.
Tematy:
constructed wetland
vertical flow
domestic wastewater
common reed
Glyceria maxima
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/124123.pdf  Link otwiera się w nowym oknie
Opis:
The paper presents the results of research on the effects of removing pollution from domestic wastewater in two beds of constructed wetland systems with vertical flow. Bed I was planted with common reed (Phragmites australis Cav. Trin. Ex Steud.), whereas bed II with Glyceria maxima (Glyceria aquatica L.). The surface of each of the beds amounted to 30 m2, and the hydraulic load of each of them amounted to 0.033 m3·m-2·d-1. The study showed very good results in the removal of most of the analyzed indicators of contamination, which were similar in both analyzed beds. They were, respectively: 91 and 93% – for total suspended solids, 96 and 98% – for BOD5, 96 and 94% – for CODCr, 88 and 86% – for ammonia nitrogen and 87 and 88% – for total phosphorus. Much smaller effects were reported with regard to total nitrogen removal – 55% in bed I with common reed and 54% in bed II with Glyceria maxima. The tested beds also eliminated the number of coliform bacteria and faecal coliform bacteria quite effectively. Average effects of the removal of coliform bacteria in bed I and II were 99.74%, in the case of faecal coliform 98.06% and 97.94% respectively. Values of basic indicators of contamination (total suspended solids, BOD5 and CODCr) in the wastewater discharged from the analyzed beds met the requirements of the Regulation of the Minister of the Environment of 2014. The test results obtained in the first year of operation of the analyzed beds show that neither of the applied plants significantly improves the results of contaminant removal.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Trickling Filter and Vertical Flow Constructed Wetland Bed to Treat Sewage from Craft Brewery
Autorzy:
Dąbrowski, Wojciech
Karolinczak, Beata
Tematy:
craft brewery
sewage treatment
trickling filter
vertical flow constructed wetland
Certyd
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/124568.pdf  Link otwiera się w nowym oknie
Opis:
In Poland, as well as worldwide, an increase in craft beer production can be observed. In the last several years, more than 150 of such breweries have appeared and according to Polish Brewery Association, their number might ultimately reach 500. Many of them emerge in the areas with no access to a central sewerage system so they have to solve the problem of waste management on their own. The article presents the results of research on the possibility of using a hybrid system for biological treatment of sewage from craft breweries. The sewage came from a craft brewery Waszczukowe located in the Podlaskie province. A laboratory scale model consisted of a trickling filter (TF) (research model Gunt CE701e) and vertical flow constructed wetland (SS-VF). Innovative filling (Certyd produced by LSA company) of TF and SS VF was applied. The conducted study included determining the changes in the sewage parameters during hybrid treatment, as well as TF and SS VF efficiency separately. The aim of the research was to show the possibility of treating sewage to a point when it was possible to discharge it to a receiver, in compliance with the Polish legal regulations. The research results might be used in designing a treatment system or sewage pretreatment in craft breweries. The average efficiency of TF operating with 100% recirculation was 76% for BOD5, 80% for COD, 26% for TN and 34% for TP, while the total treatment efficiency of a hybrid system (TF and SS-VF) was 98%, 98%, 72% and 77%, respectively. The load of TF during operation with recirculation was on average 0.38 kg BOD5 m-2d-1, 0.57 kg COD m-2 d-1. The load of SS-VF was on average 0.09 kg BOD5 m-2 d-1 and 0.12 kg COD m-2d-1. The obtained results of hybrid treatment permitted to discharge the sewage to the receiver.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of vertical shaft of mixed-flow pump
Modelowanie pionowego wału pompy diagonalnej
Autorzy:
Holka, H.
Jarzyna, T.
Tematy:
modelling
vertical mixed-flow pump
numerical analysis
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Powiązania:
https://bibliotekanauki.pl/articles/950678.pdf  Link otwiera się w nowym oknie
Opis:
The aim of the work was modelling of shaft and calculation of natural vibration frequencies and critical rotations of a large-size, vertical mixed flow pump of total length l=4866 mm. Equations of motion were determined analytically, and then calculation results were verified by numerical modelling. The difficulty of the problem consisted in the shaft bearing, in which four hydrodynamic bearings of unknown parameters were applied. A four-mass beam supported on flexible supports of rigidity k and damping c was assumed as the discrete model of the shaft. Equations of motion for the system were derived with the method of forces. In order to verify correctness of the derived equations, one considered three models of the beam with different support configuration: the beam supported on rigid supports, the beam supported on elastic supports, and the beam supported on flexible supports of rigidity k and damping c. Calculation results are presented in tables and graphs.
Celem pracy jest modelowanie wału dużej pionowej pompy diagonalnej, o długości całkowitej: l=4866mm oraz obliczenie częstości drgań własnych i obrotów krytycznych. Wyznaczono analitycznie równania ruchu a następnie sprawdzono uzyskane rezultaty obliczeń za pomocą modelowania numerycznego. Utrudnienie pracy stanowiło ułożyskowanie wału w czterech łożyskach hydrodynamicznych o nieznanych parametrach. Jako model dyskretny wału przyjęto belkę czteromasową podpartą na podatnych podporach o sztywności k i tłumieniu c. Równania ruchu układu wyprowadzono metodą sił. W celu zweryfikowania poprawności wyprowadzonych równań rozważano modele belek w trzech etapach różniących sie konfiguracją podparcia: belka podparta na sztywnych podporach, belka podparta na podporach sprężystych, belka podparta na podporach podatnych o sztywności k i tłumieniu c. Rezultaty obliczeń podano w tabelach i na wykresach.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of Organic Substances and Ammonia Nitrogen Removal in Vertical Flow Constructed Wetlands
Autorzy:
Malinowski, Paweł
Dąbrowski, Wojciech
Tematy:
treatment modeling
vertical flow constructed wetlands
reject water
organic substances
ammonia nitrogen
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/124762.pdf  Link otwiera się w nowym oknie
Opis:
The aim of the research was to determine the possibility of using and adapting regression models for a description of constructed wetland systems treating reject water from aerobic sewage sludge stabilization. The P-k-C* model was investigated along with related models. The research was carried out using reject water from aerobic sewage sludge stabilization in dairy wastewater treatment plant (WWTP) belonging to Mlekovita in Wysokie Mazowieckie. The main components of the research installation were two vertical flow constructed wetland beds with passive aeration operating at 0.1 m/d hydraulic load. The following parameters were used for modeling: BOD5, COD, N-NH4+ and temperature. Air temperature was also monitored.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie fosforu na filtrach z wypełnieniem z granulatu z popiołów ze spalania osadów ściekowych
Phosphorus removal in filters filled with lwa made of fly ashes
Autorzy:
Rodziewicz, J.
Mielcarek, A.
Kłodowska, I.
Janczukowicz, W.
Choińska-Żurek, E.
Wolter, A.
Tematy:
wypełnienie typu LECA
filtr pionowy
usuwanie fosforu
LECA
vertical-flow filter
phosphorus removal
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/401294.pdf  Link otwiera się w nowym oknie
Opis:
Celem badań było określenie efektywności usuwania fosforu ze ścieków na filtrach pionowych wypełnionych żwirem oraz granulatem przygotowanym z popiołów powstających podczas procesu spalania osadów ściekowych (FASSTT LWA). Syntetyczne ścieki zawierające 7,36 mg/L fosforu wprowadzano do kolumn filtracyjnych wypełnionych żwirem i FASSTT LWA (dolną warstwę wypełnienia stanowił żwir, podczas gdy górna warstwa z FASSTT LWA zajmowała odpowiednio 0, 12, 25, 50, i 100% wypełnienia kolumny). Badania prowadzono dla obciążeń hydraulicznych równych 0,003, 0,005 i 0,007 m/d. Wykazano, że efektywność usuwania fosforu ze ścieków na filtrach z wypełnieniem zawierającym granulat zależała od proporcji między żwirem i granulatem. Usuwanie fosforu odbywało się głównie wskutek procesu adsorpcji na powierzchni wypełnienia filtru. Najwyższą efektywność usuwania fosforu, niezależnie od zastosowanego obciążenia hydraulicznego, uzyskano dla filtru o 50% zawartości granulatu typu LECA i 50% zawartości żwiru. Potwierdzono możliwość wykorzystania popiołów z procesu spalania osadów ściekowych do produkcji granulatu i zastosowania wypełnienia z granulatu w filtrach do oczyszczania ścieków zanieczyszczonych związkami fosforu.
The effectiveness of phosphorus removal in vertical-flow filters with double-layer filling composed of light weight aggregate made of fly ashes from sewage sludge thermal treatment (FASSTT LWA) and gravel was determined. Synthetic wastewaters containing 7.36 mg/L of phosphorus were fed into filter columns filled with gravel and FASSTT LWA (gravel was the bed’s lower layer, whereas the top layer of the FASSTT LWA constituted 0, 12, 25, 50, and 100% of the depth of the column) at hydraulic loads from 0.003, to 0.007 m/d. The study demonstrated that the efficiency of phosphorus removal depends on the ratio between the gravel and FASSTT LWA. Phosphorus removal is mainly due to adsorption on the surface of the filter filling. The highest phosphorus removal rate was achieved in the filter column with 50% FASSTT LWA and 50% gravel content, irrespective of the hydraulic load applied. The study confirmed the possibility of using FASSTT LWA to produce granular filling and application as the filling of filter columns used for the treatment of wastewaters containing significant concentration of phosphorus.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of SS-VF Bed for the Treatment of High Concentrated Reject Water from Autothermal Termophilic Aerobic Sewage Sludge Digestion
Autorzy:
Dąbrowski, W.
Malinowski, P.
Karolinczak, B.
Tematy:
autothermal thermophilic aerobic digestion
ATAD
reject water
vertical flow constructed wetland
SS VF
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/123643.pdf  Link otwiera się w nowym oknie
Opis:
The autothermal termophilic aerobic digestion (ATAD) technology is used in the municipal and industrial wastewater treatment plants (WWTPs) with personal equivalent up to 30.000. The process provides a high level of sewage sludge stabilization and its hygienization. The main operation problems are caused by the high concentration of nitrogen and phosphorus in the reject water from sewage sludge treatment and air purification (odor removal). Reject water usually is returned to the main sewage treatment, which has a negative impact, especially on the sewage treatment systems based on the sequence batch reactors (SBR). Applying high-performance and expensive separate reject water treatment methods such as SHARON, Anammox or CANON in small facilities is not justified economically. The article presents the research results concerning the effectiveness of applying subsurface vertical flow constructed wetlands (SS VF) for reject water treatment from the ATAD process. An innovative type of bed filling was used, which was produced from waste (ash from a heat and power plant). The efficiency of reject water treatment during the research period was on average at 45.6% for ammonia nitrogen, 32.3% for total phosphorus and 85.1% for BOD5. Applying SS VF beds for separate reject water treatment might ensure a stable and effective functioning of municipal WWTPs by decreasing the load of biological part of a WWTP.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektywności gruntowo-roślinnych oczyszczalni ścieków na podstawie wyników rocznego projektu badawczego
Effectiveness of vertical flow constructed wetlands based on results of the annual research project
Autorzy:
Tomczuk, B.
Ochrymiuk, D.
Tematy:
przydomowe oczyszczalnie ścieków
złoża hydrofitowe o przepływie pionowym
ścieki bytowo-gospodarcze
domestic sewage treatment plants
vertical flow constructed wetlands
household sewage
Pokaż więcej
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Powiązania:
https://bibliotekanauki.pl/articles/400024.pdf  Link otwiera się w nowym oknie
Opis:
W artykule przedstawiono wyniki rocznego monitoringu efektywności ośmiu gruntowo-roślinnych oczyszczalni ścieków wybudowanych w ramach projektu Centrum Zielonych Technologii, realizowanego przez Podlaską Stację Przyrodniczą NAREW. Celem badań było sprawdzenie, czy obok wysokiej efektywności ekonomicznej i wysokiego poziomu satysfakcji użytkowników, zapewniają one również wymaganą efektywność oczyszczania.
The paper presents results of the annual research project on effectiveness of eight vertical flow constructed wetland built within the framework of the Centrum Zielonych Technologii project, which was conducted by Podlaska Stacja Przyrodnicza NAREW. The aim of the research was to prove whether or not the constructed wetlands provide required ecological effectiveness apart from their high economical efficiency as well as high level of users' satisfaction.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vertical distribution of nearshore flow velocity
Autorzy:
Li, Ch.
Fu, X.
Li, R.
Dai, L.
Chen, P.
Tematy:
vertical distribution of flow velocity
Jiangsu Sea
nearshore
exponential formula
Pokaż więcej
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Powiązania:
https://bibliotekanauki.pl/articles/259609.pdf  Link otwiera się w nowym oknie
Opis:
In this paper, a new exponential formed vertical distribution of nearshore flow velocity is constructed, which is simpler in form and more suitable for engineering application. The physical meaning of the new formula is more specific than that of Soulsby. Compared with those logarithmic formed ones, the new one does not need the maximum velocity and only needs the mean velocity in vertical, which gives it better engineering practicability. Apply the new formula to Jiangsu coastal area and compare the results with that of Soulsby whose results show the new formula agrees better with the measured flow velocity, which reasonably reflects the basic principles of vertical distribution of flow velocity.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model fazy dyskretnej przepływu powietrza z wykropleniem pary wodnej
Discrete phase model of air flow with the water vapor condensation
Autorzy:
Branny, M.
Nowak, B.
Ptaszyński, B.
Kuczera, Z.
Łuczak, R.
Życzkowski, P.
Tematy:
dwufazowy przepływ pionowy
model fazy dyskretnej
wentylacja kopalń
vertical two-phase flow
discrete phase model
mine ventilation
Pokaż więcej
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Powiązania:
https://bibliotekanauki.pl/articles/349114.pdf  Link otwiera się w nowym oknie
Opis:
W artykule opisano zastosowanie modelu fazy dyskretnej do opisu przepływu powietrza w pionowych szybach wentylacyjnych z kondensacją pary wodnej. Dokonano sprawdzenia warunków, w jakich można stosować model fazy dyskretnej i zaprezentowano wyniki obliczeń dla takich prędkości powietrza w szybach, że przy modelowanych wydatkach masowych monodyspersyjnych strumieni kropel wody, pochodzących z kondensacji, cała woda była wynoszona przez powietrze na powierzchnię.
The paper describes the use of the discrete phase model to describe the movement of air in the vertical ventilation shafts with condensation of water vapor. Conditions under which discrete phase model can be used were verified and the results of performed calculations were presented. The results were obtained fo vertical movement up to the drops of water in the shaft.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Minimizing indoor infection risks with automotive nanofiltration and with laminar vertical flow
Autorzy:
Czerwiński, Jan
Mayer, Andreas
Mayer, Jörg
Burtscher, Heinz
Lutz, Thomas
Mayer, Rainer
Rothen-Rutishauser, Barbara
Frey, Joachim
Lämmle, Christian
Rüggeberg, Tobias
Specht, Patrick
Tematy:
ventilation for virus protection
vertical laminar flow
nanoparticle separation
virus deactivation
ceramic honeycomb wall flow filter
nanofiltration
wentylacja dla ochrony przeciwwirusowej
pionowy przepływ laminarny
rozdzielanie nanocząstek
dezaktywacja wirusa
filtr ceramiczny o strukturze plastra miodu
nanofiltracja
Pokaż więcej
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Powiązania:
https://bibliotekanauki.pl/articles/24202467.pdf  Link otwiera się w nowym oknie
Opis:
The knowledge about nanoaerosols, their potential health effects, their measurement, limitation and administrative-legal treatment has been developed in the last 3 decades in connection with the exhaust gas cleaning of the combustion engines. Nanofiltration, which has thus become known, almost completely eliminates nanoparticles with filters of high durability, high specific filtration areas, and reasonable costs. On the occasion of the Covid pandemic, NanoCleanAir experimentally proved that the viruses in an automotive filter substrate are separated as well as the combustion particles and are also deactivated. To minimize cross exchange of infectious aerosol, new attention must be paid to flow management in ventilated spaces. Digitized flow analysis has also received significant inspiration from engine technology in the past. This paper provides information on some basic investigations and gives valuable advice based on the experimental and numerical results of a retrofitted classroom.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies