Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "x-ray microtomography" wg kryterium: Temat


Tytuł:
Osmotic dehydration and freezing as a suitable pretreatment in the process of vacuum drying kiwiberry: drying kinetics and microstructural changes
Autorzy:
Bialik, M.
Wiktor, A.
Witrowa-Rajchert, D.
Samborska, K.
Gondek, E.
Findura, P.
Tematy:
Actinidia arguta
X-ray microtomography
mathematical modelling
drying kinetics
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Powiązania:
https://bibliotekanauki.pl/articles/2082900.pdf  Link otwiera się w nowym oknie
Opis:
This study investigated the effects of osmotic dehydration and freezing on the kinetics and microstructure of vacuum-dried kiwiberry. Both fresh and previously frozen fruit were dehydrated in sucrose, maltitol and xylitol. Freezing and osmotic dehydration were selected as possible ways to improve the drying kinetics and positively influence the taste of the fruit. This experiment focused on the analysis of microstructural changes induced by applied processing methods using the X-ray microtomography technique. The results showed that the fruit pretreated in sucrose suffered the least structural damage as expressed by the largest condensation of small pores and thin cell walls. Freezing and xylitol resulted in the accumulation of larger pores and thicker walls. The most rapid drying time of 678-688 min was observed for unfrozen samples, dehydrated in sucrose and maltitol. Freezing slowed down the drying process, by 60-100 min, in comparison to the unfrozen samples. The applied mathematical models proved useful in predicting the kinetics of the drying process. The equation proposed by Midilli et al. provided the best fit for predicting the kinetics of the process.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray microtomography (XMT) of fossil brachiopod shell interiors for taxonomy
Autorzy:
Blazejowski, B.
Binkowski, M.
Bitner, M.A.
Gieszcz, P.
Tematy:
x-ray microtomography
fossil
brachiopod
shell
taxonomy
remains
paleontology
Terebratula terebratula
Pokaż więcej
Wydawca:
Polska Akademia Nauk. Instytut Paleobiologii PAN
Powiązania:
https://bibliotekanauki.pl/articles/23513.pdf  Link otwiera się w nowym oknie
Opis:
The ability to see and understand the three−dimensional structure of an investigated object plays a key role in studying fossil remains. All living organisms are formed in threedimensions, but unfortunately fossilization processes often reduce overall shape, making it difficult to gather information about real overall appearance, functionality, and inner structure. Here, using a specimen of the brachiopod Terebratula terebratula we demonstrate a non−destructive technique for exploring the 3−D internal structure of fossil remains. The use of tomography allows the construction of a set of transverse serial sections in the manner used by brachiopod researchers for decades.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the carbonation zone in concrete using X-ray microtomography
Autorzy:
Łydżba, D.
Rajczakowska, M.
Stefaniuk, D.
Kmita, A.
Tematy:
concrete
carbonation zone
X-ray microtomography
beton
strefa karbonatyzacji
mikrotomografia rentgenowska
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/178832.pdf  Link otwiera się w nowym oknie
Opis:
The article presents an application of X-ray microtomography for identification of the carbonation zone in concrete material. A concrete specimen subjected earlier to harsh environmental conditions is investigated. The material is firstly checked with the use of chemical corrosion indicators and then is subjected to microstructural analysis performed with the use of X-ray microtomography. Two different settings of scanning parameters are applied implying the image resolutions of approximately 14 μm per 1 pixel and about 7 μm per 1 pixel, respectively. The results obtained are then compared and analyzed. The depth of the carbonation zone is evaluated based on the attenuation curve. The paper highlights also the significance of the corrosion phenomenon in concrete structures. Details of the deterioration mechanisms in concrete are shortly presented.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray microtomography (μCT) as a useful tool for visualization and interpretation of shear strength test results
Autorzy:
Stefaniuk, D.
Tankiewicz, M.
Stróżyk, J.
Tematy:
X-ray microtomography
shear strength
shear plane
fine-grained soil
triaxial test
Pokaż więcej
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Powiązania:
https://bibliotekanauki.pl/articles/178870.pdf  Link otwiera się w nowym oknie
Opis:
The paper demonstrates the applicability of X-ray microtomography (μCT) to analysis of the results of shear strength examinations of clayey soils. The method of X-ray three-dimensional imaging offers new possibilities in soil testing. The work focuses on a non-destructive method of evaluation of specimen quality used in shear tests and mechanical behavior of soil. The paper presents the results of examination of 4 selected clayey soils. Specimens prepared for the triaxial test have been scanned using μCT before and after the triaxial compression tests. The shear strength parameters of the soils have been estimated. Changes in soil structure caused by compression and shear failure have been presented as visualizations of the samples tested. This allowed for improved interpretation and evaluation of soil strength parameters and recognition of pre-existing fissures and the exact mode of failure. Basic geometrical parameters have been determined for selected cross-sections of specimens after failure. The test results indicate the utility of the method applied in soil testing.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda pomiaru gęstości osadu pokoagulacyjnego z zastosowaniem tomografii rentgenowskiej
Measurement method of sediment densities after coagulation using x-ray tomography
Autorzy:
Rząsa, M. R.
Podgórni, E.
Tematy:
gęstość osadu
koagulacja
mikrotomografia rentgenowska
density of sediment
coagulation
X-ray microtomography
Pokaż więcej
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Powiązania:
https://bibliotekanauki.pl/articles/268323.pdf  Link otwiera się w nowym oknie
Opis:
Koagulacja jest jednym z procesów oczyszczania wody. Polega na destabilizacji układu koloidalnego i aglomeracji cząstek, które następnie usuwa się w procesach sedymentacji, flotacji czy filtracji. Powstałe cząstki pokoagulacyjne charakteryzują się zróżnicowanym kształtem, wielkością oraz strukturą. Szybkość opadania takich cząstek w dużej mierze zależy od ich gęstości. Struktura cząstek powoduje, że wyróżnia się dwa rodzaje porów. Makropory, które nie powinny być uwzględniane przy wyznaczaniu gęstości oraz mikropory, które stanowią cechę charakteryzującą dany osad pokoagulacyjny. Gęstość wyznaczono metodą wagową dla odpowiednio przygotowanych próbek. Ponieważ proces prasowania może niszczyć mikrostrukturę osadu, przeprowadzono badania mające na celu określenie stopnia sprasowania próbek, aby zminimalizować błędy wyznaczenia gęstości. Badania te prowadzono za pomocą tomografu rentgenowskiego, dzięki któremu możliwe było wyznaczenie objętości danej próbki z korektą makroporowatości. W pracy przedstawiono wyniki badań oraz parametry graniczne procesu przygotowywania próbek.
Coagulation is one of the processes of water purification, which consists in the destabilization of the dispersion and agglomeration of the particles, which are removed in the process of sedimentation, flotation or filtration. After the coagulation particles have a varied shape, size and porous structure. The rate of descent of such particles largely depends on their density. The structure of the particles causes two types of pores. Macropores that should not be taken into account when determining the density, and micropores, which are a characteristic feature of the sediment after coagulation process. To determine the density of sludge samples were subjected to compression, in order to eliminate the macropores and then, after designation of sample volume, density was determined by weighing. The precipitate was prepared based on a prepared water model, to which was added a coagulant Flokor 1.2A. The precipitate was filtered on a cellulose filter, and then subjected to a drying process. The dry sludge was pressed on the press impact. Because of the pressing process can destroy the microstructure of the sediment, studies have been conducted to determine the degree of compression of samples to minimize errors while determine the density. These studies were carried out using X-ray tomography, it was possible to designate the volume of the sample while subtraction residues macropores. For the correct determination of the volume, determination the correct number of threshold is necessary, based on which is possible to qualify individual pixels. In order to clearly identify which pixels represent sediment, it was necessary to carry out the image processing. That process were performed using LabVIEW software and Vision module. The paper presents results of research for density measurement and sets limits for the sample preparation process.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-invasive analysis and visualization of objects from FSW AlSi9Mg/2017A aluminum alloy joints
Nieinwazyjna analiza i wizualizacja obiektów w złączach AlSi9Mg/2017A wytwarzanych metodą Friction Stir Welding
Autorzy:
Wójcicka, A.
Mroczka, K.
Kowalski, M.
Tematy:
X-ray microtomography
image analysis
aluminum alloys
FSW
mikrotomografia komputerowa
analiza obrazów
stopy aluminium
Pokaż więcej
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Powiązania:
https://bibliotekanauki.pl/articles/264301.pdf  Link otwiera się w nowym oknie
Opis:
Friction stir welding (FSW) technology allows for the welding of materials that differ in their chemical compositions, microstructures, and properties. When selecting the parameters, it is necessary to analyze the structure of a weld and eliminate the defects. The use of X-ray microtomography creates the possibility of precise imaging of a joint structure – especially when it contains defects (voids). The tests were carried out on an FSW joint made with both 2017A and AlSi9Mg aluminum alloys. The macrostructure was cross-sectional, and a defect was found in the middle part of the joint and on the advancing side. We used a conventional method of observation light microscopy. Then, an analysis was performed using X-ray microtomography, which revealed the shape of the defect in 3D. Individual cross-sections were extracted, which enabled us to measure the geometric quantities. A dependence was found for the shape of the defect on the welding parameters and the variability of its construction. The usefulness of this advanced material imaging technology for the analysis of FSW welds has been confirmed.
Technologia FSW umożliwia zgrzewanie materiałów różniących się składem chemicznym, mikrostrukturą i właściwościami. Przy doborze parametrów konieczna jest analiza struktury złącza i eliminacja ewentualnych wad. Zastosowanie mikrotomografii komputerowej umożliwia precyzyjne obrazowanie budowy złącza, szczególnie gdy zawiera wady (pustki). Badania przeprowadzono na złączu FSW stopów aluminium 2017A i AlSi9Mg. Zbadano makrostrukturę na przekroju poprzecznym i stwierdzono obecność wady w środkowej części złącza i po stronie natarcia. Zastosowano konwencjonalną metodę obserwacji – mikroskopię świetlną. Następnie wykonano analizę złącza z zastosowaniem tomografii komputerowej, która ujawniła kształt wady w wymiarze 3D. Wyekstrahowano poszczególne przekroje, które umożliwiły wykonanie pomiarów wielkości geometrycznych. Stwierdzono zależność kształtu wady od parametrów zgrzewania oraz zmienność jej budowy. Potwierdzono przydatność tej zaawansowanej technologii obrazowania budowy materiałów do analizy złącz FSW.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przestrzenne badanie systemu porowego skał węglanowych na podstawie cyfrowej analizy obrazów mikrotomograficznych z wykorzystaniem języka Python
Spatial analysis of carbonate pore system based on digital image analysis of X-ray microtomography data using Python language
Autorzy:
Fheed, Adam
Hadro, Piotr
Tematy:
mikrotomografia rentgenowska
Phyton
węglanowe skały zbiornikowe
porowatość
X-ray microtomography
Python
carbonate reservoir rocks
porosity
Pokaż więcej
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Powiązania:
https://bibliotekanauki.pl/articles/2076181.pdf  Link otwiera się w nowym oknie
Opis:
The main aim of this contribution is to combine a Python-supported analysis of X-ray microtomography (µCT) images and the transmitted-light microscopy to resolve the factors controlling the variability of petrophysical parameters in carbonate rocks. A self-developed Python script for the evaluation of pore connectivity and the computation of pore sizes based on µCT data was prepared. The script was launched on a carbonate sample with drawn from a drill core representing the Late Permian Zechstein Limestone (Ca1) formation from the Wolsztyn Ridge area in West Poland. The sample was taken from the upper part of the isolated Kokorzyn Reef, corresponding to a brachiopod and bivalve-rich zone. The plug had a cylindrical shape, the diameter of 2.54 cm and the height of approximately 4.6cm. The entire volume of the plug was scanned using a GE Nanotom Sdevice. The 3D-reconstructeddatasetobtainedwith spatial resolution of 0.02 mm underwent cropping, contrast adjustment, noise reduction and porosity extraction using open-source Fiji software. The binarized porosity image was loaded into the Python script. Python scripting was found efficient in carbonate pore system examination. The code first extracted the connected pore system of the largest volume and computed the smallest distances between porosity voxels and corresponding pore walls. The obtained results were confronted with the spatially-adjusted microphotographs taken in plane-polarized transmitted light. The results have shown that narrow and isolated pores occurred within the spines of brachiopods. The largest voids were found inside the brachiopod shells. Moreover, many pores were associated with partially dissolved fragments of bivalves. Porosity reduction was -most outlined in the zones showing the scarcity of fossils.
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problem of the objects detection on low quality 3D image – example solution
Autorzy:
Gądek-Moszczak, A.
Tematy:
image processing
low contrast
noise
X-ray microtomography
przetwarzanie obrazu
hałas
mikrotomografia rentgenowska
redukcja szumów
poprawa kontrastu
Pokaż więcej
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Powiązania:
https://bibliotekanauki.pl/articles/114988.pdf  Link otwiera się w nowym oknie
Opis:
Precise detection of analyzed objects is crucial and the most important task in quantitative and qualitative image of the microstructure analysis. The most common image distortion is noise, artefacts and low contrast. In the paper, author on the example of poor quality image of the polyurethane-polystyren composite structure, obtained with the X-ray microtomograph, presented possible methods of noise reduction, contrast enhancement, and correction of detection errors on the binary image.
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies